原发性乳腺癌患者局部与全身分期:基于18F-FDG PET/MRI的一步法与两步法分期比较
本研究前瞻性纳入38例新诊断、组织病理学证实的乳腺癌患者,比较一步法(仰卧位全身18F-FDG PET/MRI)与两步法(俯卧位乳腺专用PET/MRI联合仰卧位全身PET/MRI)的诊断价值。患者分析中两步法正确识别37/38例(97%),一步法为33/38例(87%);病灶分析中两步法检出56个乳腺癌病灶,一步法正确识别44个(79%),差异有统计学意义(p=0.0015)。腋窝淋巴结评估的敏感度、特异度和准确率分别为93%、95%和94%,两种算法均检出7例远处转移。
要点
- 两步法(俯卧位乳腺PET/MRI+仰卧位全身PET/MRI)患者水平正确识别率97%(37/38),一步法为87%(33/38)。
- 病灶水平两步法检出56个乳腺癌病灶,一步法正确识别44个(79%),差异有统计学意义(p=0.0015)。
- 腋窝淋巴结评估敏感度93%、特异度95%、准确率94%;两种算法均检出7例远处转移。
核心结论
- 结果表明,在乳腺癌局部与全身分期中,包含俯卧位乳腺专用成像和仰卧位全身成像的两步法18F-FDG PET/MRI较一步法具有必要性和优越性。
研究设计与样本
- 前瞻性纳入38例(37例女性、1例男性,平均年龄57±10岁,范围31-78岁)新诊断、组织病理学证实的乳腺癌患者,比较一步法与两步法18F-FDG PET/MRI分期算法。
主要发现
- 患者分析中两步法正确识别37/38例乳腺癌(97%),一步法正确识别33/38例(87%)。
- 病灶分析中两步法检出56个乳腺癌病灶,一步法正确识别44个(79%),两种算法差异有统计学意义(p=0.0015)。
- 腋窝淋巴结评估的敏感度为93%、特异度为95%、准确率为94%。
- 两种算法均检出7例患者的远处转移。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The purpose of this study was to compare the diagnostic value of a one-step to a two-step staging algorithm utilizing 18F-FDG PET/MRI in breast cancer patients. METHODS: A total of 38 patients (37 females and one male, mean age 57 ± 10 years; range 31-78 years) with newly diagnosed, histopathologically proven breast cancer were prospectively enrolled in this trial. All PET/MRI examinations were assessed for local tumor burden and metastatic spread in two separate reading sessions: (1) One-step algorithm comprising supine whole-body 18F-FDG PET/MRI, and (2) Two-step algorithm comprising a dedicated prone 18F-FDG breast PET/MRI and supine whole-body 18F-FDG PET/MRI. RESULTS: On a patient based analysis the two-step algorithm correctly identified 37 out of 38 patients with breast carcinoma (97%), while five patients were missed by the one-step 18F-FDG PET/MRI algorithm (33/38; 87% correct identification). On a lesion-based analysis 56 breast cancer lesions were detected in the two-step algorithm and 44 breast cancer lesions could be correctly identified in the one-step 18F-FDG PET/MRI (79%), resulting in statistically significant differences between the two algorithms (p = 0.0015). For axillary lymph node evaluation sensitivity, specificity and accuracy was 93%, 95 and 94%, respectively. Furthermore, distant metastases could be detected in seven patients in both algorithms. CONCLUSION: The results demonstrate the necessity and superiority of a two-step 18F-FDG PET/MRI algorithm, comprising dedicated prone breast imaging and supine whole-body imaging, when compared to the one-step algorithm for local and whole-body staging in breast cancer patients.
引用
- Kirchner J, Grueneisen J, Martin O, et al. Local and whole-body staging in patients with primary breast cancer: a comparison of one-step to two-step staging utilizing 18F-FDG-PET/MRI. Eur J Nucl Med Mol Imaging. 2018. PMID: 30056547. doi:10.1007/s00259-018-4102-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。