文献速递神经核医学肿瘤 PET/CT

联合68Ga-NOTA-PRGD2与18F-FDG PET/CT可鉴别模拟高级别胶质瘤的少见脑膜瘤

Combined 68Ga-NOTA-PRGD2 and 18F-FDG PET/CT Can Discriminate Uncommon Meningioma Mimicking High-Grade Glioma.
PubMed 文献 · Clin Nucl Med · 2018-01-01

前瞻性队列研究纳入21例MRI疑诊高级别胶质瘤(HGG)患者,行68Ga-NOTA-PRGD2 PET/CT并在3天内行脑18F-FDG PET/CT比较,术后病理证实5例为少见脑膜瘤、16例为HGG。少见脑膜瘤的68Ga-NOTA-PRGD2 SUVmax及RGD/FDG比值均高于HGG, cutoff值1.58可鉴别两类病变。

要点

  • 21例MRI疑诊HGG患者中,5例最终病理为少见脑膜瘤伴严重瘤周脑水肿。
  • 少见脑膜瘤68Ga-NOTA-PRGD2 SUVmax为4.23±2.48,高于HGG的1.57±0.33(P=0.0047)。
  • RGD/FDG比值在少见脑膜瘤为1.87±1.36,高于HGG的1.04±0.87(P=0.0001),cutoff值1.58可鉴别。

核心结论

  • 本研究揭示模拟HGG的少见脑膜瘤具有特异性影像模式,68Ga-NOTA-PRGD2 PET对18F-FDG PET具有附加价值。

研究设计与样本

  • 2013年至2016年前瞻性招募21例MRI疑诊HGG的患者,行68Ga-NOTA-PRGD2 PET/CT,并在3天内行脑18F-FDG PET/CT比较,肿瘤经手术切除。
  • PET结果与肿瘤样本的整合素αvβ3表达及微血管密度定量进行比较。

主要发现

  • 21例中5例最终病理诊断为少见脑膜瘤伴严重瘤周脑水肿,包括脊索样脑膜瘤(n=1)、血管瘤型脑膜瘤(n=1)、混合血管瘤型与微囊型脑膜瘤(n=3);16例诊断为HGG。
  • 全部5例脑膜瘤病灶均表现为68Ga-NOTA-PRGD2摄取浓密且均匀,SUVmax为1.64-7.86(均值±标准差,4.23±2.48),高于HGG病灶的0.81-2.99(均值±标准差,1.57±0.33;P=0.0047)。
  • 少见脑膜瘤的RGD/FDG摄取比值(以lg100*SUVmax标准化)为1.87±1.36,显著高于HGG的1.04±0.87(P=0.0001);cutoff值1.58可鉴别两类病变。
  • 整合素αvβ3表达水平、微血管密度与68Ga-NOTA-PRGD2 PET衍生的肿瘤/本底比值之间呈正相关(P<0.05)。

关键数值与推荐

  • 68Ga-NOTA-PRGD2 PET的SUVmax cutoff值1.58可鉴别少见脑膜瘤与HGG。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Uncommon pathological subtypes of meningioma may present with severe peritumoral brain edema and mimic high-grade glioma (HGG). In a prospective cohort study of Ga-NOTA-PRGD2 PET/CT to evaluate glioma, we occasionally observed that a combination of Ga-NOTA-PRGD2 and F-FDG was able to differentiate these 2 lesion types. METHODS: From 2013 to 2016, 21 patients suspected of HGG by MRI were recruited for evaluation using Ga-NOTA-PRGD2 PET/CT. Brain F-FDG PET/CT was performed within 3 days for comparison, and the tumor was surgically removed. The PET results were compared with integrin αvβ3 expression and microvascular density quantification of tumor samples. RESULTS: Of the 21 recruited patients, 5 patients were finally pathologically diagnosed as uncommon meningioma with severe peritumoral brain edema, including chordoid meningioma (n = 1), angiomatous meningioma (n = 1), and mixed angiomatous and microcystic meningioma (n = 3). Sixteen were diagnosed as HGG. All the meningioma lesions (n = 5) exhibited intense and homogeneous Ga-NOTA-PRGD2 uptake with higher SUVmax on Ga-NOTA-PRGD2 PET (1.64-7.86; mean ± SD, 4.23 ± 2.48) than the HGG lesions (0.81-2.99; mean ± SD, 1.57 ± 0.33; P = 0.0047). Moreover, the uptake ratios of Ga-NOTA-PRGD2 over F-FDG, normalized as lg100 * SUVmax (RGD / FDG), in the uncommon meningiomas were significantly higher than those in HGG (1.87 ± 1.36 vs 1.04 ± 0.87, P = 0.0001). A cutoff value of 1.58 was able to discriminate between these lesion types. There were positive correlations among the expression level of integrin αvβ3, microvascular density, and the tumor-to-background ratio derived from Ga-NOTA-PRGD2 PET (P < 0.05). CONCLUSIONS: This study reveals a specific imaging pattern of uncommon meningioma mimicking HGG, in which Ga-NOTA-PRGD2 PET provided added value to F-FDG PET.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Li D, Zhang J, Ji N, et al. Combined 68Ga-NOTA-PRGD2 and 18F-FDG PET/CT Can Discriminate Uncommon Meningioma Mimicking High-Grade Glioma. Clin Nucl Med. 2018. PMID: 30052597. doi:10.1097/RLU.0000000000002233

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。