动态负荷201Tl/静息99mTc-替曲膦单光子发射计算机断层成像定量稳定型冠状动脉疾病患者心肌灌注储备的可行性
前瞻性纳入34例已知或疑似稳定型冠状动脉疾病患者,采用镉锌碲探测器专用多针孔SPECT相机行动态负荷201Tl/静息99mTc-替曲膦SPECT,用Corridor4DM软件定量心肌灌注储备(MPR)。全局MPR平均2.58±1.03,区域MPR与直径狭窄、最小管腔直径、负荷总评分及血流储备分数(FFR)均相关;MPR诊断功能性显著狭窄(FFR≤0.8)的曲线下面积为0.79,以2.0为界值敏感度67%、特异度83%。作者认为该动态SPECT定量MPR在稳定型CAD患者中可行,但小样本初步结果需更大队列确认。
要点
- 动态负荷201Tl/静息99mTc-替曲膦SPECT可定量MPR,34例稳定型CAD患者中全局MPR平均2.58±1.03。
- 区域MPR与FFR相关(r=0.52,P<0.001),诊断FFR≤0.8狭窄的AUC为0.79。
- 以MPR 2.0为界值,诊断功能性显著狭窄的敏感度67%、特异度83%。
核心结论
- 动态负荷201Tl/静息99mTc-替曲膦SPECT成像并定量MPR在稳定型CAD患者中是可行的。
- 作者指出该小样本患者的初步结果需在更大队列中确认,以确定其对提升SPECT在CAD诊断和风险预测中作用的意义。
研究设计与样本
- 前瞻性纳入已知或疑似稳定型冠状动脉疾病、已接受或计划接受FFR测量的受试者,共34例(男25例、女9例,平均年龄60.4岁)。
- 使用镉锌碲探测器专用多针孔SPECT相机行动态负荷201Tl/静息99mTc-替曲膦SPECT成像,用Corridor4DM软件导出MPR。
- 对65条中等病变冠状动脉行FFR测量。
主要发现
- 全局MPR平均为2.58±1.03。
- 全局MPR与CAD范围相关(P=0.028),与全局负荷总评分相关(r=-0.60,P<0.001)。
- 区域MPR与直径狭窄相关(r=-0.57,P<0.001),与最小管腔直径相关(r=0.50,P<0.001)。
- 区域MPR与负荷总评分相关(r=-0.52,P<0.001),与FFR相关(r=0.52,P<0.001)。
- MPR诊断功能性显著狭窄(FFR≤0.8)的受试者工作特征曲线下面积为0.79(P<0.001)。
关键数值与推荐
- 以区域MPR界值2.0诊断功能性显著狭窄(FFR≤0.8),敏感度为67%、特异度为83%。
临床怎么用
- 原文未据此给出推荐。
- 作者认为动态负荷201Tl/静息99mTc-替曲膦SPECT定量MPR在稳定型CAD患者中可行,其初步结果需在更大队列中确认。
局限性
- 作者指出该研究为小样本患者的初步结果,需在更大队列中确认。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We evaluated the feasibility of dynamic stress 201Tl/rest 99mTc-tetrofosmin SPECT imaging using a cardiac camera equipped with cadmium-zinc-telluride detectors for the quantification of myocardial perfusion reserve (MPR). METHODS: Subjects with stable known or suspected coronary artery disease (CAD) who had undergone or were scheduled to undergo fractional flow reserve (FFR) measurement were prospectively enrolled. Dynamic stress 201Tl/rest 99mTc-tetrofosmin SPECT imaging was performed using a dedicated multiple pinhole SPECT camera with cadmium-zinc-telluride detectors. MPR was derived using Corridor4DM software. RESULTS: A total of 34 subjects were enrolled (25 men and 9 women; mean age 60.4 years). FFR was measured in 65 coronary arteries with intermediate lesions. The average global MPR was 2.58 ± 1.03. Global MPR was associated with the extent of CAD (P = 0.028) and global summed stress score (r = -0.60, P < 0.001). Regional MPR showed a significant correlation with diameter stenosis (r = -0.57, P < 0.001), minimum lumen diameter (r = 0.50, P < 0.001), summed stress score (r = -0.52, P < 0.001) and FFR (r = 0.52, P < 0.001). The area under the receiver operating characteristic curve of MPR for the diagnosis of functionally significant stenosis (FFR ≤0.8) was 0.79 (P < 0.001). The sensitivity and specificity of regional MPR were 67% and 83%, respectively, using a cut-off value of 2.0. CONCLUSION: Dynamic stress 201Tl/rest 99mTc-tetrofosmin SPECT imaging and quantification of MPR is feasible in patients with stable CAD. The preliminary results of this study in a small number of patients require confirmation in a larger cohort to determine their implications for bolstering the role of SPECT imaging in the diagnosis and risk prediction of CAD.
引用
- Han S, Kim YH, Ahn JM, et al. Feasibility of dynamic stress 201Tl/rest 99mTc-tetrofosmin single photon emission computed tomography for quantification of myocardial perfusion reserve in patients with stable coronary artery disease. Eur J Nucl Med Mol Imaging. 2018. PMID: 29858614. doi:10.1007/s00259-018-4057-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。