超低剂量CT用于碲锌镉单光子发射计算机断层心肌灌注显像衰减校正

Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging.
PubMed 文献 · J Nucl Cardiol · 2018-06-19

研究纳入100例接受一日法99mTc-替曲膦负荷-静息MPI的患者,比较120、80和70 kVp管电压CT衰减校正图。80 kVp和70 kVp与120 kVp的归一化心肌摄取相关性极好(ICC均约0.988/0.985),Bland-Altman限窄、偏差小;平均有效辐射剂量分别为0.58±0.07、0.19±0.02和0.12±0.01 mSv。结论认为超低剂量CT衰减图与标准剂量CT衰减图可互换,同时大幅降低辐射剂量。

要点

  • 80 kVp与120 kVp衰减校正SPECT-MPI归一化心肌摄取相关性极好(ICC=0.988/0.985),偏差小。
  • 70 kVp与120 kVp衰减校正SPECT-MPI相关性同样极好(ICC=0.988/0.986),Bland-Altman限窄。
  • 平均有效辐射剂量:120 kVp为0.58±0.07 mSv,80 kVp为0.19±0.02 mSv,70 kVp为0.12±0.01 mSv。

核心结论

  • 超低辐射剂量CT扫描获得的MPI衰减图与标准剂量CT衰减图可互换,同时大幅降低辐射剂量暴露。

研究设计与样本

  • 100例患者接受一日法99mTc-替曲膦负荷-静息MPI,并接受120、80和70 kVp管电压、管电流200毫安的非增强心脏CT以创建衰减校正图。

主要发现

  • 80 kVp与120 kVp衰减校正SPECT-MPI归一化心肌摄取负荷相关性极好(ICC=0.988,95%CI=0.986-0.989,P<.001),静息相关性极好(ICC=0.985,95%CI=0.983-0.987,P<.001),Bland-Altman限分别为-5.3%至4.5%和-5.4%至4.4%,偏差分别为-0.4%和-0.5%。
  • 70 kVp与120 kVp衰减校正SPECT-MPI负荷相关性极好(ICC=0.988,95%CI=0.986-0.989,P<.001),静息相关性极好(ICC=0.986,95%CI=0.984-0.987,P<.001),Bland-Altman限分别为-5.3%至4.4%和-5.2%至4.5%,偏差分别为-0.4%和-0.3%。
  • 120、80和70 kVp扫描的平均有效辐射剂量分别为0.58±0.07、0.19±0.02和0.12±0.01 mSv。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The applicability of ultra-low-dose computed tomography (CT) for attenuation correction (AC) of single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) remains elusive. METHODS AND RESULTS: One-hundred patients underwent one-day 99mTc-tetrofosmin stress-rest MPI and non-contrast enhanced cardiac CT with 120, 80, and 70 kilovolt peak (kVp) tube voltage and tube current of 200 milliamperes for creation of AC maps. Normalized percent myocardial uptake from SPECT-MPI using 80 kVp scans for AC showed excellent correlation vs AC from 120 kVp scans for stress [intraclass correlation (ICC) = 0.988, 95% CI = 0.986-0.989, P < .001] and rest (ICC = 0.985, 95% CI = 0.983-0.987, P < .001) with narrow Bland-Altman limits of agreement (BA-LA) (- 5.3% to 4.5% and - 5.4% to 4.4%, respectively) and minimal bias (- 0.4% and - 0.5%, respectively). Correlation of AC SPECT-MPI based on 70 vs 120 kVp scans was excellent for stress (ICC = 0.988, 95% CI = 0.986-0.989, P < .001) and rest (ICC = 0.986, 95% CI = 0.984-0.987, P < .001) with narrow BA-LA (- 5.3% to 4.4% and - 5.2% to 4.5%, respectively) and small bias (- 0.4% and - 0.3%, respectively). Mean effective radiation dose for the 120, 80 and 70 kVp scans were 0.58 ± 0.07, 0.19 ± 0.02, and 0.12 ± 0.01 mSv, respectively. CONCLUSIONS: Attenuation maps for MPI obtained from ultra-low radiation dose CT scans are interchangeable with attenuation maps from standard-dose CT while offering a substantial reduction in radiation dose exposure.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。