前列腺癌评估中18F-胆碱摄取定量的时间采样优化
研究比较7种动态18F-氟甲基胆碱PET时间采样方案,基于32例前列腺癌患者37个病灶,选用1T2k+VB模型,以目标K1值0.506 mL/ccm/min为标准,模拟显示12×5″-8×30″采样最接近目标值,临床验证中该方案与多数其他采样K1值有显著差异。
要点
- 1T2k+VB模型被选用于动态18F-氟甲基胆碱PET的TAC分析。
- 模拟TAC中12×5″-8×30″采样提取的K1最接近目标值0.506 mL/ccm/min。
- 临床验证中12×5″-8×30″与多数其他采样K1值有显著差异。
核心结论
- 动态PET重建采用两阶段帧方案(血池相5秒、组织相30秒)可用于前列腺癌评估中TAC的摄取定量采样。
研究设计与样本
- 比较37个病灶(来自32例因前列腺癌初诊或复发评估接受FCH PET的患者)的不可逆与可逆单组织 compartment 模型(1T1K+VB与1T2k+VB),用Akaike信息准则选择模型;采用蒙特卡洛法从1000条噪声模拟TAC中提取K1,比较7种时间采样方案。
主要发现
- 选择1T2k+VB模型;目标K1值为0.506 mL/ccm/min(范围0.216-1.246)。
- 7种时间采样方案模拟TAC提取的K1值之间差异显著;12×5″-8×30″采样提取的K1最接近目标值。
- 临床验证中,12×5″-8×30″采样提取的K1值与其他采样方案显著不同,但与10×5″-4×10″-3×20″-5×30″采样比较无显著差异。
关键数值与推荐
- 目标K1值(37个病灶使用成像衍生输入函数提取的K1平均值)为0.506 mL/ccm/min(范围0.216-1.246)。
- 最优时间采样方案为12×5″-8×30″,即12帧5秒加8帧30秒。
临床怎么用
- 作者认为动态PET重建可采用血池相5秒、组织相30秒的两阶段帧方案进行前列腺癌评估中的摄取定量采样。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Suboptimal temporal sampling of time-activity curves (TAC) from dynamic 18F-fluoromethylcholine (FCH) PET images may introduce bias in quantification of FCH uptake in prostate cancer assessment. We sought to define an optimal temporal sampling protocol for dynamic FCH PET imaging. Seven different time samplings were tested: 5 × 60″, 10 × 30″, 15 × 15″-1 × 75″, 6 × 10″-8 × 30″, 12 × 5″-8 × 30″; 10 × 5″-4 × 10″-3 × 20″-5 × 30″, and 8 × 3″-8 × 12″-6 × 30″. First, the irreversible and reversible one-tissue compartment model with blood volume parameter (VB) (respectively, 1T1K+VB and 1T2k+VB, with K1 = transfer coefficient from the arterial blood to the tissue compartment and k2 = transfer coefficient from the tissue compartment to the arterial blood) were compared for 37 lesions from 32 patients who underwent FCH PET imaging for initial or recurrence assessment of prostate cancer, and the model was selected using the Akaike information criterion. To determine the optimal time sampling, K1 values extracted from 1000 noisy-simulated TAC using Monte Carlo method from the seven different time samplings were compared to a target K1 value which is the average of the K1 values extracted from the 37 lesions using an imaging-derived input function for each patient. K1 values extracted with the optimal time sampling for each tumoral lesion were compared to K1 values extracted from each of the other time samplings for the 37 lesions. RESULTS: The 1T2k + VB model was selected. The target K1 value as the objective was 0.506 mL/ccm/min (range 0.216-1.246). Results showed a significant difference between K1 values from the simulated TAC with the seven different time samplings analyzed. The closest K1 value from the simulated TAC to the target K1 value was obtained by the 12 × 5″-8 × 30″ time sampling. Concerning the clinical validation, K1 values extracted from the optimal time sampling (12 × 5″-8 × 30″) were significantly different with K1 values extracted from the other time samplings, except for the comparison with K1 values extracted from the 10 × 5″-4 × 10″-3 × 20″-5 × 30″ time sampling. CONCLUSIONS: A two-phase framing of dynamic PET reconstruction with frame durations of 5 s (blood phase) and 30 s (tissue phase) could be used to sample the TAC for uptake quantification in prostate cancer assessment.
引用
- Palard-Novello X, Blin AL, Le Jeune F, et al. Optimization of temporal sampling for 18F-choline uptake quantification in prostate cancer assessment. EJNMMI Res. 2018. PMID: 29904817. doi:10.1186/s13550-018-0410-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。