文献速递肿瘤 PET/CT放射性药物与辐射防护

18F-FDG PET/CT 在疑似血管移植物感染诊断中的诊断效能:一项前瞻性队列研究

Diagnostic yield of 18F-FDG PET/CT in suspected diagnosis of vascular graft infection: A prospective cohort study.
PubMed 文献 · J Nucl Cardiol · 2018-06-15

该前瞻性队列研究纳入49例疑似人工血管移植物感染(PVGI)患者,采用已发表推荐定义的三种摄取模式(局灶型、斑片型、弥漫型)判读18F-FDG PET/CT。结果显示灵敏度88%、特异度79%、阳性预测值67%、阴性预测值93%。作者结论认为18F-FDG PET/CT对PVGI诊断有用,但在因放置人工血管移植物而使用粘合剂的患者中,斑片型摄取不提示感染。

要点

  • 49例疑似PVGI患者中,18F-FDG PET/CT灵敏度88%、特异度79%、阳性预测值67%、阴性预测值93%。
  • 14/16例PVGI表现为局灶型(n=10)或斑片型(n=4);26/33例无感染者表现为弥漫型(n=16)或无摄取(n=10)。
  • 7例假阳性中5例(71%)为斑片型,且均与放置人工血管移植物时使用粘合剂同时出现。

核心结论

  • 18F-FDG PET/CT是诊断PVGI的有用技术。
  • 在因放置人工血管移植物而使用粘合剂的患者中,PET/CT上的斑片型表现不提示感染。

研究设计与样本

  • 前瞻性队列研究,纳入49例疑似PVGI患者,中位年龄62±14岁。
  • 依据已发表推荐定义三种摄取模式:局灶型、斑片型(作为PVGI判据)、弥漫型(不作为PVGI判据)。

主要发现

  • 18F-FDG PET/CT诊断PVGI的灵敏度为88%、特异度为79%、阳性预测值为67%、阴性预测值为93%。
  • 18F-FDG PET/CT识别出14/16例PVGI,表现为局灶型(n=10)或斑片型(n=4)。
  • 18F-FDG PET/CT在26/33例无PVGI者中为真阴性,表现为弥漫型(n=16)或无摄取(n=10)。
  • 7例假阳性中5例(71%)表现为斑片型,且均与放置人工血管移植物时使用粘合剂同时出现。

关键数值与推荐

  • 摄取模式判定:局灶型、斑片型(PVGI判据)、弥漫型(非PVGI判据)。
  • 灵敏度88%、特异度79%、阳性预测值67%、阴性预测值93%。
  • 14/16例PVGI为局灶型(n=10)或斑片型(n=4);26/33例无PVGI为弥漫型(n=16)或无摄取(n=10)。
  • 7例假阳性中5例(71%)为斑片型,均与使用粘合剂放置人工血管移植物同时出现。

临床怎么用

  • 作者认为18F-FDG PET/CT是诊断PVGI的有用技术。
  • 作者指出,在因放置人工血管移植物而使用粘合剂的患者中,PET/CT的斑片型表现不提示感染。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Prosthetic vascular graft infection (PVGI) is a severe complication associated with high morbidity and mortality. Clinical diagnosis is complex, requiring image testing such as CT angiography or leukocyte scintigraphy, which has considerable limitations. The aim of this study was to know the diagnostic yield of PET/CT with 18F-Fluorodeoxyglucose (18F-FDG) in patients with suspected PVGI. METHODS: We performed a prospective cohort study including 49 patients with suspected PVGI, median age of 62 ± 14 years. Three uptake patterns were defined following published recommendations: (i) focal, (ii) patched (PVGI criteria), and (iii) diffuse (no PVGI criterion). RESULTS: Sensitivity, specificity, and positive and negative predictive values for 18F-FDG-PET/CT were 88%, 79%, 67%, and 93%, respectively. 18F-FDG-PET/CT identified 14/16 cases of PVGI showing a focal (n = 10) or patched pattern (n = 4), being true negative in 26/33 cases with either a diffuse pattern (n = 16) or without uptake (n = 10). Five of the seven false-positive cases (71%) showed a patched pattern and all coincided with the application of adhesives for PVG placement. CONCLUSIONS: 18F-FDG-PET/CT is a useful technique for the diagnosis of PVGI. A patched pattern on PET/CT in patients in whom adhesives were applied for prosthetic vascular graft placement does not indicate infection.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Bowles H, Ambrosioni J, Mestres G, et al. Diagnostic yield of 18F-FDG PET/CT in suspected diagnosis of vascular graft infection: A prospective cohort study. J Nucl Cardiol. 2018. PMID: 29907934. doi:10.1007/s12350-018-1337-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。