CZT相机与传统γ相机在心肌SPECT中衰减伪影模式的差异
本研究通过体模和患者测量,比较多针孔碲锌镉(CZT)相机(GE NM 530c)与传统γ相机(GE Ventri)在心肌灌注成像SPECT中衰减伪影的定位、范围和深度。所有图像均使用外源性低剂量CT进行衰减校正,通过比较衰减校正与非衰减校正图像量化伪影。结果显示CZT相机使衰减伪影从下侧壁向侧壁移位,伪影范围更大(患者23±5% vs 15±5%,P<.001),但深度更浅(患者72±3% vs 68±4%,P<.001)。
要点
- CZT相机较传统相机使衰减伪影从下侧壁移位至侧壁,体模与患者结果一致。
- 患者中CZT相机衰减伪影范围显著大于传统相机(23±5% vs 15±5%,P<.001)。
- CZT相机衰减伪影深度(最大计数的百分比)较传统相机更浅(患者72±3% vs 68±4%,P<.001)。
核心结论
- 使用CZT相机与传统γ相机进行心肌灌注SPECT时,衰减伪影的定位、范围和深度均不同,评估图像时应考虑此差异以避免误判心肌灌注分布。
研究设计与样本
- 体模与患者测量研究,使用CZT相机(GE NM 530c)和传统γ相机(GE Ventri),所有图像均用外源性低剂量CT进行衰减校正。
主要发现
- 衰减伪影从下侧壁向侧壁移位,CZT相机较传统相机在患者和体模中均如此。
- 患者中衰减伪影范围CZT相机为23±5%,传统相机为15±5%(P<.001);体模中分别为28%和19%。
- 患者中衰减伪影深度(最大计数的百分比)CZT相机为72±3%,传统相机为68±4%(P<.001);体模中分别为73%和67%。
临床怎么用
- 原文结论指出,评估心肌灌注SPECT图像时应考虑CZT相机与传统相机衰减伪影定位、范围和深度的差异,以避免误判心肌灌注分布。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In myocardial perfusion imaging (MPI), single-photon emission tomography (SPECT) soft-tissue attenuation by the abdomen, breasts, and lateral chest wall may create artifacts that mimic true perfusion defects. This may cause misdiagnosis of myocardial perfusion. The aim of the present study was to compare the localization, extent, and depth of attenuation artifacts in MPI SPECT for a multi-pinhole cadmium zinc telluride (CZT) camera vs a conventional gamma camera. METHODS: Phantom and patient measurements were performed using a CZT camera (GE NM 530c) and a conventional gamma camera (GE Ventri). All images were attenuation corrected with externally acquired low-dose computed tomography. The localization, extent, and depth of the attenuation artifact were quantified by comparing attenuation-corrected and non-attenuation-corrected images. RESULTS: Attenuation artifacts were shifted from the inferolateral wall to the lateral wall using the CZT camera compared to a conventional camera in both the patient and the phantom. The extent of the attenuation artifact was significantly larger for the CZT camera compared to the conventional camera (23 ± 5% vs 15 ± 5%, P < .001) for patients and the result was similar for the phantom (28% vs 19%). Furthermore, the depth of the attenuation artifact (percent of maximum counts) was less pronounced for the CZT camera than for the conventional camera, both for phantom measurements (73% vs 67%) and patients (72 ± 3% vs 68 ± 4%, P < .001). CONCLUSIONS: Attenuation artifacts are found in different locations to different extents and depths when using a CZT camera vs a conventional gamma camera for MPI SPECT. This should be taken into consideration when evaluating MPI SPECT studies to avoid misinterpretation of myocardial perfusion distribution.
引用
- Oddstig J, Martinsson E, Jögi J, et al. Differences in attenuation pattern in myocardial SPECT between CZT and conventional gamma cameras. J Nucl Cardiol. 2018. PMID: 29796975. doi:10.1007/s12350-018-1296-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。