文献速递肿瘤 PET/CT

基于18F-FDG PET/CT测量的肿瘤体积表面比估算的肿瘤碎裂是弥漫性大B细胞淋巴瘤的独立预后因素

Tumor fragmentation estimated by volume surface ratio of tumors measured on 18F-FDG PET/CT is an independent prognostic factor of diffuse large B-cell lymphoma.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2018-04-28

该研究回顾性纳入215例弥漫性大B细胞淋巴瘤患者,在R-CHOP或强化R-CHOP方案前进行18F-FDG PET/CT,测量总代谢肿瘤体积(TMTV)及基于 marching cube 算法计算的总肿瘤表面(TTS)和肿瘤体积表面比(TVSR)。多因素Cox分析显示TMTV和TVSR均为独立预后因素,且二者联合有协同预后价值。

要点

  • TVSR与TMTV相关性弱(ρ=0.5),TTS与TMTV高度相关(ρ=0.94)故被排除。
  • 预测5年OS的最佳截断值:TMTV为222 cm3,TVSR为6.0 mm。
  • 多因素Cox分析中TMTV(HR 2.8)和TVSR(HR 2.1)均为独立显著预后因素。

核心结论

  • 基于初始18F-FDG PET测量的TVSR是弥漫性大B细胞淋巴瘤的独立预后因素,与TMTV、IPI评分和化疗类型联合时具有额外预后价值。

研究设计与样本

  • 回顾性纳入215例弥漫性大B细胞淋巴瘤患者,初始18F-FDG PET/CT在R-CHOP(73%)或强化R-CHOP(R-ACVBP)方案(27%)前进行。
  • TMTV采用SUVmax的41%固定阈值测量,TTS和TVSR使用基于marching cube算法的院内软件计算表面。
  • 采用Spearman秩相关系数、ROC分析、Kaplan-Meier法及单/多因素Cox分析进行统计。

主要发现

  • TVSR与TMTV相关性弱(ρ=0.5),与TTS相关性弱(ρ=0.26);TTS与TMTV高度相关(ρ=0.94),因此TTS被排除出分析。
  • TMTV的ROC曲线下面积最高(0.711),敏感性最佳(0.797);TVSR的特异性最佳(0.745)。
  • 预测5年OS的最佳截断值:TMTV为222 cm3,TVSR为6.0 mm。
  • 高TMTV和高TVSR患者在Kaplan-Meier和Cox单因素分析中预后显著更差。
  • 多因素Cox分析中所有参数均为独立显著预后因素:IPI HR 1.4(95%CI 1.1-1.8),化疗类型 HR 4.5(95%CI 2.0-10.5),TMTV HR 2.8(95%CI 1.4-5.5),TVSR HR 2.1(95%CI 1.3-3.4)。

关键数值与推荐

  • TMTV测量采用SUVmax的41%固定阈值。
  • 预测5年OS的最佳截断值:TMTV为222 cm3,TVSR为6.0 mm。
  • 多因素Cox分析中IPI HR 1.4(95%CI 1.1-1.8),化疗类型 HR 4.5(95%CI 2.0-10.5),TMTV HR 2.8(95%CI 1.4-5.5),TVSR HR 2.1(95%CI 1.3-3.4)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Our aim was to study the prognostic value of two new 18F-FDG PET biomarkers in diffuse large B-cell lymphoma (DLBCL). We examined the total tumor surface (TTS), describing the tumor-host interface, and the tumor volume surface ratio (TVSR), corresponding to the ratio between the total metabolic tumor volume (TMTV) and TTS, describing the tumor fragmentation. METHODS: We retrospectively included 215 patients with DLBCL. Patients underwent initial 18F-FDG PET/CT before R-CHOP (73%) or intensified R-CHOP (R-ACVBP) regimens (27%). The TMTV was measured using a fixed threshold value of 41% of SUVmax. To calculate TTS and TVSR, the surface was measured using an in-house software based on the marching cube algorithm. Spearman's rank correlation coefficient (ρ) was computed between TMTV, TTS, and TVSR, and ROC analysis was performed. Survival functions at 5 years were studied using a Kaplan-Meier method and uni/multivariate Cox analysis. RESULTS: TVSR was poorly correlated with TMTV (ρ = 0.5) and TTS (ρ = 0.26), while TTS was highly correlated with TMTV (ρ = 0.94) and was, therefore, excluded from the analysis. TMTV had the highest area under the ROC curve (0.711) and the best sensitivity (0.797), while TVSR had the best specificity (0.745). The optimal cut-off values to predict 5-year OS were 222 cm3 for TMTV and 6.0 mm for TVSR. Patients with high TMTV and TVSR had significantly worse prognosis in Kaplan-Meier and Cox univariate analysis. In a multivariate Cox analysis combining the International Prognostic Index (IPI), the type of chemotherapy, TMTV, and TVSR, all parameters were independent and significant prognostic factors (HR [95%CI]: IPI 1.4 [1.1-1.8], type of chemotherapy 4.5 [2.0-10.5], TMTV 2.8 [1.4-5.5], TVSR 2.1 [1.3-3.4]). A synergistic effect between TMTV and TVSR was observed in a Kaplan-Meier analysis combining the two parameters. CONCLUSIONS: TVSR measured on the initial 18F-FDG PET is an independent prognostic factor in DLBCL and has an additional prognostic value when combined with TMTV, IPI score and chemotherapy.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Decazes P, Becker S, Toledano MN, et al. Tumor fragmentation estimated by volume surface ratio of tumors measured on 18F-FDG PET/CT is an independent prognostic factor of diffuse large B-cell lymphoma. Eur J Nucl Med Mol Imaging. 2018. PMID: 29705879. doi:10.1007/s00259-018-4041-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。