文献速递心脏核医学

在大鼠中通过房室模型分析用Tc-99m MIBI无创估算定量心肌血流量

Noninvasive estimation of quantitative myocardial blood flow with Tc-99m MIBI by a compartment model analysis in rat.
PubMed 文献 · J Nucl Cardiol · 2018-04-13

研究在大鼠中利用动态平面图像和达峰时间图设置感兴趣区,通过房室模型分析估算心肌血流量,并与微球技术比较。两种方法所得心肌血流量显著相关,虽存在负比例偏倚但均值无显著差异。结论认为该方法有助于在大鼠中实现绝对心肌血流量测量。

要点

  • 在大鼠中,基于达峰时间图设置感兴趣区的房室模型分析所得心肌血流量与微球技术显著相关。
  • 两种方法所得心肌血流量均值无显著差异,但存在负比例偏倚。
  • 作者认为该方法有助于在大鼠中实现绝对心肌血流量测量。

核心结论

  • 利用达峰时间图的房室模型分析估算心肌血流量,有助于在大鼠中实现绝对心肌血流量测量。

研究设计与样本

  • 研究纳入21只正常大鼠,获取Tc-99m MIBI动态平面图像,利用达峰时间图设置输入函数和心脏感兴趣区。
  • 心肌血流量分别通过结合Renkin-Crone模型的单房室模型分析和微球技术估算。

主要发现

  • 两种方法所得心肌血流量显著相关。
  • 观察到负比例偏倚,但两种方法计算的心肌血流量均值之间无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We aimed to investigate the use of dynamic cardiac planar images to estimate myocardial blood flow (MBF) by a compartment model analysis using time-to-peak (TP) map and compared it by the microsphere technique in rat. Positron emission tomography is considered the gold standard method, but is not available everywhere. By contrast, although myocardial perfusion imaging (MPI) with single-photon tracers is more widely available, it may be difficult to obtain adequate region of interest (ROI) settings. We proposed using the TP map to set the ROI, and hypothesized that this method could facilitate the measurement of absolute MBF by MPI in rat. METHODS: Twenty-one normal rats were studied. Dynamic planar images with Tc-99m MIBI were obtained, and input function and cardiac ROIs were set using the obtained TP map. MBF was estimated by a one-compartment model analysis with the Renkin-Crone model and by the microsphere technique. RESULTS: The MBFs from these two methods were significantly correlated. A negative proportional bias was observed, but no significant difference was observed between the mean MBFs calculated with each method. CONCLUSIONS: MBF estimation by a compartment model analysis using TP map could facilitate absolute MBF measurement in rats.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Okizaki A, Nakayama M, Nakajima K, et al. Noninvasive estimation of quantitative myocardial blood flow with Tc-99m MIBI by a compartment model analysis in rat. J Nucl Cardiol. 2018. PMID: 29654445. doi:10.1007/s12350-018-1274-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。