文献速递肿瘤 PET/CT

镓68-PSMA-11 PET/CT在前列腺癌成像中的特征:检测限与定量特性

Hallmarks in prostate cancer imaging with Ga68-PSMA-11-PET/CT with reference to detection limits and quantitative properties.
PubMed 文献 · EJNMMI Res · 2018-04-04

本研究用表达PSMA的LNCaP细胞(单细胞悬液或三维球体)与不表达PSMA的HCT116细胞混合成2×10^5个细胞的沉淀,经镓68-PSMA-11孵育后在圆柱形水模体内用临床常规方案行全身PET/CT成像。无本底时需1×10^4个LNCaP细胞达到50%检测概率,本底1 kBq/ml时需4×10^5至1×10^6个细胞;放射配体平衡解离常数为27.05 nM,比活度对图像定量有深远影响,作者认为应排除使用标准化摄取值进行定量。

要点

  • 无本底时,1×10^4个LNCaP细胞混于2×10^5个细胞沉淀中可达50%检测概率。
  • 本底水平1 kBq/ml时,需4×10^5至1×10^6个LNCaP细胞达到检测。
  • 放射配体平衡解离常数为27.05 nM,比活度对图像定量有深远影响。

核心结论

  • 镓68-PSMA-11 PET/CT即使LNCaP细胞混于不表达PSMA的细胞群中且存在本底,仍可检测少量LNCaP细胞。
  • 获得的图像检测限和定量特性是患者管理个体化的重要特征。
  • 作者认为镓68-PSMA-11 PET/CT图像定量应排除使用标准化摄取值。

研究设计与样本

  • 体外实验:人前列腺癌LNCaP细胞(表达PSMA)以不同细胞数的单细胞悬液或三维球体收集,与镓68-PSMA-11孵育。
  • 随后加入人HCT116细胞(PSMA阴性)至每管总细胞数2×10^5个,离心弃上清。
  • 用临床常规方案的全身PET/CT扫描仪对置于圆柱形水模体内的沉淀成像,本底放射性活度递增。
  • 用自动伽马计数器测量实际结合到细胞的放射性活度,获得图像检测限和活度恢复系数随LNCaP细胞数的变化。
  • 另用递增浓度放射配体孵育LNCaP细胞样本,研究镓68-PSMA-11质量浓度对细胞结合的影响。

主要发现

  • 无本底时,需要1×10^4个LNCaP细胞混于2×10^5个细胞的沉淀中,才能达到50%检测概率。
  • 本底水平为1 kBq/ml时,需要4×10^5至1×10^6个细胞。
  • 放射配体平衡解离常数为27.05 nM,表明高结合亲和力。
  • 放射配体的比活度对图像定量有深远影响。

临床怎么用

  • 作者认为镓68-PSMA-11 PET/CT图像定量应排除使用标准化摄取值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Gallium-68-labeled prostate-specific antigen positron emission tomography/computed tomography imaging (Ga68-PSMA-11-PET/CT) has emerged as a potential gold standard for prostate cancer (PCa) diagnosis. However, the imaging limitations of this technique at the early state of PCa recurrence/metastatic spread are still not well characterized. The aim of this study was to determine the quantitative properties and the fundamental imaging limits of Ga68-PSMA-11-PET/CT in localizing small PCa cell deposits. METHODS: The human PCa LNCaP cells (PSMA expressing) were grown and collected as single cell suspension or as 3D-spheroids at different cell numbers and incubated with Ga68-PSMA-11. Thereafter, human HCT116 cells (PSMA negative) were added to a total cell number of 2 × 105 cells per tube. The tubes were then pelleted and the supernatant aspirated. A whole-body PET/CT scanner with a clinical routine protocol was used for imaging the pellets inside of a cylindrical water phantom with increasing amounts of background activity. The actual activity bound to the cells was also measured in an automatic gamma counter. Imaging detection limits and activity recovery coefficients as a function of LNCaP cell number were obtained. The effect of Ga68-PSMA-11 mass concentration on cell binding was also investigated in samples of LnCaP cells incubated with increasing concentrations of radioligand. RESULTS: A total of 1 × 104 LNCaP cells mixed in a pellet of 2 × 105 cells were required to reach a 50% detection probability with Ga68-PSMA-11-PET/CT without background. With a background level of 1 kBq/ml, between 4 × 105 and 1 × 106 cells are required. The radioligand equilibrium dissociation constant was 27.05 nM, indicating high binding affinity. Hence, the specific activity of the radioligand has a profound effect on image quantification. CONCLUSIONS: Ga68-PSMA-11-PET detects a small number of LNCaP cells even when they are mixed in a population of non-PSMA expressing cells and in the presence of background. The obtained image detection limits and characteristic quantification properties of Ga68-PSMA-11-PET/CT are essential hallmarks for the individualization of patient management. The use of the standardized uptake value for Ga68-PSMA-11-PET/CT image quantification should be precluded.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Sanchez-Crespo A, Jussing E, Björklund AC, et al. Hallmarks in prostate cancer imaging with Ga68-PSMA-11-PET/CT with reference to detection limits and quantitative properties. EJNMMI Res. 2018. PMID: 29619657. doi:10.1186/s13550-018-0378-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。