心脏123I-mIBG显像在预测接受ICD的稳定慢性心力衰竭患者心律失常事件中的作用
前瞻性研究纳入170例因一级或二级预防接受ICD植入的慢性心力衰竭患者,评估平面和SPECT 123I-mIBG显像对心律失常事件的预测价值。但123I-mIBG衍生参数均非恰当ICD治疗的独立预测因子。
要点
- 早期 summed SPECT 评分是全组心律失常事件的唯一独立预测因子(HR 1.023)。
- 一级预防亚组中早期 summed SPECT 评分亦为唯一独立预测因子(HR 1.028)。
- 123I-mIBG衍生参数与恰当ICD治疗无独立预测关联,呈钟形关系。
核心结论
- SPECT 123I-mIBG显像与因一级和二级预防植入ICD的慢性心力衰竭患者的心律失常事件相关,但123I-mIBG显像衍生参数与恰当ICD治疗之间未发现关联。
研究设计与样本
- 前瞻性研究,纳入170例因一级和二级预防接受ICD植入的慢性心力衰竭患者,所有患者接受平面和SPECT显像。
主要发现
- 中位随访23.3个月期间,69例患者发生心律失常事件。
- 123I-mIBG衍生参数均未能成为恰当ICD治疗的独立预测因子。
- 123I-mIBG显像衍生参数与心律失常事件及恰当ICD治疗之间呈钟形关系,即中等程度123I-mIBG异常者事件风险倾向更高。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Despite therapeutic improvement, the prognosis of chronic heart failure (CHF) remains unfavorable partly due to arrhythmia and sudden cardiac death (SCD). This prospective study evaluated myocardial 123I-meta-iodobenzylguanidine (123I-mIBG) scintigraphy as a predictor of arrhythmic events (AE) in CHF patients. METHODS: 170 CHF patients referred for implantable cardioverter-defibrillator (ICD) implantation for both primary and secondary prevention were enrolled. All patients underwent planar and SPECT imaging. Early and late heart-to-mediastinum (H/M) ratio, 123I-mIBG washout (WO), early and late summed SPECT scores were calculated The primary endpoint was an AE: sustained ventricular tachycardia, resuscitated cardiac arrest, appropriate ICD therapy or SCD. The secondary endpoint was appropriate ICD therapy. RESULTS: During a median follow-up of 23.3 months, 69 patients experienced an AE. Early summed score (ESS) was the only independent predictor of AE [HR 1.023 (1.003-1.043)]. Focussing on only patients with an ICD for primary prevention, ESS was the only independent predictor of AE [HR 1.028 (1.007-1.050)]. 123I-mIBG-derived parameters failed to be independent predictors of appropriate ICD therapy. However there was a "bell-shaped" relation between 123I-mIBG scintigraphy-derived parameters and AE and appropriate ICD therapy, i.e., those with intermediate 123I-mIBG abnormalities tended to be at higher risk of events. CONCLUSION: Although SPECT 123I-mIBG scintigraphy was associated with AE in CHF patients with ICD implantation for primary and secondary prevention, no association was found between 123I-mIBG scintigraphy-derived parameters and appropriate ICD therapy.
引用
- De Vincentis G, Frantellizzi V, Fedele F, et al. Role of cardiac 123I-mIBG imaging in predicting arrhythmic events in stable chronic heart failure patients with an ICD. J Nucl Cardiol. 2018. PMID: 29594915. doi:10.1007/s12350-018-1258-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。