文献速递骨显像与常规 SPECT

四分钟骨SPECT:使用大视野碲锌镉相机的可行性研究

Four-Minute Bone SPECT Using Large-Field Cadmium-Zinc-Telluride Camera.
PubMed 文献 · Clin Nucl Med · 2018-01-01

回顾性纳入30例骨SPECT患者,将原始数据(16秒/投影)重帧为10秒、5秒和3秒/投影数据集,3名评估者用4分法判定图像质量。5秒/投影被定义为最小采集时间,原始与重帧SPECT的病灶检出系数κ在各评估者均大于0.9。碲锌镉相机的高对比度图像允许5秒/投影SPECT而不损失病灶检出能力,提示可在合理时间内完成全身SPECT或降低注射剂量,尤其适用于儿童患者。

要点

  • 5秒/投影被定义为最小采集时间,原始与重帧SPECT的病灶检出κ在各评估者均大于0.9。
  • 10秒/投影数据集无患者被评为0分(质量不足以判读)。
  • 碲锌镉相机的高对比度图像支持5秒/投影SPECT而不损失病灶检出能力。

核心结论

  • 碲锌镉相机的高对比度图像允许5秒/投影SPECT而不损失病灶检出能力。
  • 这提示可在合理时间内完成全身SPECT或降低注射剂量,尤其适用于儿童患者。

研究设计与样本

  • 回顾性纳入因骨SPECT检查转诊的患者,共30例患者SPECT数据从原始数据(16秒/投影)重帧生成10秒、5秒和3秒/投影数据集。
  • 3名评估者使用4分法(0=质量不足以判读,1=一般,2=好,3=优)判定“临界”采集时间/投影,即低于该时间SPECT质量不足以判读。
  • 3名评估者(对采集时间设盲)以随机顺序评估SPECT数据集(n=79),包括原始数据和以“临界”采集时间重帧的数据。
  • 病灶定义为评估者认为任何病理性摄取,通过计算每名评估者的系数(κ)评估原始SPECT与重帧SPECT之间的病灶检出等效性。

主要发现

  • 第一个样本(n=30)的图像质量在所有评估者中随重帧数据集而显著且渐进性变差。
  • 对于5秒/投影数据集,仅1例患者被每名评估者评为0分;对于3秒/投影数据集,3例患者被评为0分;对于10秒/投影数据集,无患者被评为0分。
  • 每名评估者的最小采集时间/投影被定义为5秒/投影。
  • 原始与以临界采集时间/投影重帧的SPECT之间,每名评估者的系数κ均大于0.9。

关键数值与推荐

  • 4分法:0=质量不足以判读,1=一般,2=好,3=优。
  • 最小采集时间/投影定义为5秒/投影。
  • 原始与重帧SPECT的病灶检出系数κ在各评估者均大于0.9。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The aim of this study was to determine the minimum acquisition time without decreasing lesion detectability of bone SPECT using a whole-body cadmium-zinc-telluride camera. METHODS: Patients referred for bone SPECT were retrospectively included. SPECT of 30 patients were reframed from native data (16 s/projection) to produce 10-, 5-, and 3-s/projection data sets. A "critical" acquisition time/projection was defined as that below which the SPECT quality becomes insufficient for interpretation, as determined by 3 reviewers using a 4-point scale (0 = quality insufficient for interpretation, 1 = average, 2 = good, 3 = excellent). Three reviewers (blinded to the acquisition time) evaluated SPECT data sets (n = 79), native and reframed with "critical" acquisition times, in a randomized order. A lesion was defined as any uptake considered pathological by a reviewer. Lesion detectability equivalence between native SPECT and reframed SPECT was assessed by calculating a coefficient (κ) for each reviewer. RESULTS: Image quality of the first sample (n = 30) was significantly and progressively less well graded for the reframed data sets by all reviewers. Only 1 patient was graded 0 by each reviewer for the 5-s/projection data set. For the 3-s/projection data set, 3 patients were graded 0. No patients were graded 0 for 10-s/projection data set. The minimal acquisition time, for each projection, was defined as 5 s/projection. The coefficient κ, between native and reframed, with critical acquisition time/projection SPECT was greater than 0.9 for each reviewer. CONCLUSIONS: The more contrasted images of the cadmium-zinc-telluride camera allow performance of 5-s/projection SPECT without loss of lesion detectability. This suggests the possibility of performing whole-body SPECT in a reasonable time or reducing injected doses, especially in pediatric patients.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Gregoire B, Pina-Jomir G, Bani-Sadr A, et al. Four-Minute Bone SPECT Using Large-Field Cadmium-Zinc-Telluride Camera. Clin Nucl Med. 2018. PMID: 29561524. doi:10.1097/RLU.0000000000002062

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。