使用99mTc-HMPAO经胸部动态平面显像评估输入函数无创定量大鼠脑血流量
研究旨在建立一种无需动脉采血的大鼠脑血流量(CBF)无创定量方法,采用胸部动态平面显像估算输入函数。结果显示平面图像心脏血池积分放射性浓度与动脉血采样相同,SPECT脑放射性浓度与脑采样相同,无创CBF与常规有创法良好相关。结论为大鼠CBF可用99mTc-HMPAO胸部动态平面显像联合头部SPECT无创定量,无需动脉采血。
要点
- 平面图像心脏血池积分放射性浓度与动脉血采样相同。
- SPECT脑放射性浓度与脑采样相同。
- 无创CBF与常规有创法估算的CBF良好相关。
核心结论
- 大鼠脑血流量可用99mTc-HMPAO胸部动态平面显像和头部SPECT显像无创定量,无需动脉采血。
研究设计与样本
- 研究采用大鼠模型,以胸部动态平面显像替代动脉采血估算输入函数,并与动脉血采样及脑采样结果对比。
主要发现
- 平面图像心脏血池积分放射性浓度(AUCBlood-planar)与动脉血采样积分放射性浓度(AUCBlood-sampling)相同。
- SPECT显像测定的脑放射性浓度(CBrain-SPECT)与脑采样测定的脑放射性浓度(CBrain-sampling)相同。
- 以CBrain-SPECT除以AUCBlood-planar无创计算的CBF与以CBrain-sampling除以AUCBlood-sampling常规估算的CBF良好相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cerebral blood flow (CBF) quantitation using technetium-99m hexamethylpropyleneamine oxime (99mTc-HMPAO) generally requires assessment of input function by arterial blood sampling, which would be invasive for small animals. We therefore performed chest dynamic planar imaging, instead of arterial blood sampling, to estimate the input function and establish noninvasive quantitation method of rat CBF using the image-derived input function. RESULTS: Integrated radioactivity concentration in the heart-blood pool on planar images (AUCBlood-planar) was identical to that in arterial blood samples (AUCBlood-sampling). Radioactivity concentration in the brain determined by SPECT imaging (CBrain-SPECT) was identical to that using brain sampling (CBrain-sampling). Noninvasively calculated CBF obtained by dividing CBrain-SPECT by AUCBlood-planar was well correlated with conventionally estimated CBF obtained by dividing CBrain-sampling by AUCBlood-sampling. CONCLUSION: Rat CBF could be noninvasively quantitated using 99mTc-HMPAO chest dynamic planar imaging and head SPECT imaging without arterial blood sampling.
引用
- Suzuki C, Kosugi M, Magata Y, et al. Noninvasive quantitation of rat cerebral blood flow using 99mTc-HMPAO-assessment of input function with dynamic chest planar imaging. EJNMMI Res. 2018. PMID: 29523980. doi:10.1186/s13550-018-0375-7