文献速递心脏核医学放射性药物与辐射防护

退伍军人群体中衰减校正CT可临床干预偶然发现的报告率及变异性

Prevalence and variability in reporting of clinically actionable incidental findings on attenuation-correction CT scans in a veteran population.
PubMed 文献 · J Nucl Cardiol · 2018-02-28

该质量改进项目前瞻性评估了771例退伍军人接受心肌灌注显像时衰减校正CT上的预设可干预偶然发现,心脏科医师识别285处、放射科医师识别378处非心脏偶然发现,肺结节最常见(放射科医师阅片20%存在),两者间观察者一致性总体为一般,呼需制定CTAC阅片与报告的具体指南。

要点

  • 771例退伍军人MPI的CTAC中,心脏科医师识别285处、放射科医师识别378处非心脏偶然发现。
  • 放射科医师阅片时肺结节最常见,占20%的研究。
  • 心脏科与放射科医师对≥10 mm肺结节及食管裂孔疝的一致性差,对<10 mm肺结节、心外肿块及主动脉瘤为一般,对胸膜斑为中等。

核心结论

  • CTAC上的非心脏偶然发现在本退伍军人群体中常见,心脏科与放射科医师识别这些发现的总体观察者一致性为一般,需要制定CTAC应如何阅片和报告的具体指南。

研究设计与样本

  • 质量改进项目,前瞻性评估因MPI转诊的退伍军人的CTAC,由心脏科医师和一名放射科医师按预设的可干预偶然发现集进行评估。
  • 共评估8个月内完成的771例扫描。

主要发现

  • 心脏科医师识别285处非心脏偶然发现,放射科医师识别378处。
  • 肺结节最常见,在放射科医师阅片的研究中占20%。
  • 心脏科医师与放射科医师之间的阅片者一致性:≥10 mm肺结节和食管裂孔疝为差;<10 mm肺结节、心外肿块和主动脉瘤为一般;胸膜斑为中等。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Myocardial perfusion imaging (MPI) often employs attenuation-correction computed tomography (CTAC) to reduce attenuation artifacts and improve specificity. While there is no specific guideline on how they should be reported, incidental noncardiac findings identified on these scans may be clinically significant. The prevalence of these findings in veterans is not currently known. In addition, variability in reporting these findings may depend on the interpreting physician's specialty. METHODS: To guide future decision-making, CTACs in veterans referred for MPI were prospectively evaluated in a quality-control project for a set of prespecified actionable incidental findings by cardiologists and a radiologist. RESULTS: On the 771 scans performed over eight months, 285 incidental noncardiac findings were identified by the interpreting cardiologists and 378 were identified by the interpreting radiologist. Pulmonary nodules were the most common occurring in 20% of studies read by the radiologist. Interreader agreements between cardiologists and the radiologist were poor for pulmonary nodules ≥ 10 mm and hiatal hernias; fair for pulmonary nodules < 10 mm, extracardiac masses, and aortic aneurysms; and moderate for pleural plaques. CONCLUSION: Incidental noncardiac findings on CTACs are common in our veteran population. Overall interobserver agreement in identifying these findings between cardiologists and radiologists is fair. Specific guidelines are needed on how CTACs should be read and reported.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. He BJ, Malm BJ, Carino M, et al. Prevalence and variability in reporting of clinically actionable incidental findings on attenuation-correction CT scans in a veteran population. J Nucl Cardiol. 2018. PMID: 29492838. doi:10.1007/s12350-018-1232-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。