一日负荷-静息方案下门控灌注SPECT的容积测量变异性如何
该回顾性研究分析2158例99mTc-替曲膦心肌灌注显像患者,评估一日负荷-静息方案中门控容积指标在负荷与静息间的可重复性,以及非门控TID比值的正常变异。结果显示静息EF略高于负荷后(62.4%±10.3% vs 61.2%±10.4%,P<0.001),TID比值上限95%CI为1.23,且随静息非门控容积降低而升高。
要点
- 静息EF略高于负荷后(62.4%±10.3% vs 61.2%±10.4%,P<0.001),差值标准差5.2%(95%CI 4.9%至5.5%)。
- 非缺血患者TID比值上限95%CI为1.23,在静息非门控容积最高与最低十分位间从1.20增至1.37。
- 一日负荷-静息99mTc-替曲膦方案中,负荷与静息间LV EF下降>11.6%或TID比值>1.23可能具有临床可靠性。
核心结论
- 使用一日负荷-静息99mTc-替曲膦方案,负荷与静息间LV EF下降>11.6%或TID比值>1.23可能具有临床可靠性。
- 小LV腔容积患者的TID比值正常上限需要提高。
研究设计与样本
- 回顾性分析2158例99mTc-替曲膦心肌灌注显像患者研究。
- 排除数据不完整、明显技术困难或(仅门控分析)LV EF>75%的研究。
- 对门控数据进行分析以确定负荷与静息间心室容积和EF的可重复性。
- 对非门控容积数据进行分析以确定TID比值按心室容积的置信限。
主要发现
- 门控数据分析纳入621例无诱导性低灌注患者。
- 静息平均EF略高于负荷后(62.4%±10.3% vs 61.2%±10.4%,P<0.001),差值标准差为5.2%(95%CI 4.9%至5.5%)。
- 非门控容积数据来自992例非缺血患者。
- TID比值上限95%CI为1.23,在静息非门控容积最高与最低十分位间从1.20增至1.37。
关键数值与推荐
- 负荷与静息间LV EF下降>11.6%或TID比值>1.23可能具有临床可靠性。
- 小LV腔容积患者的TID比值正常上限需要提高。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Using myocardial perfusion scintigraphy (MPS), an increase in left ventricular (LV) volumes or a decrease in ejection fraction (EF) from rest to stress may be clinically important. The variation in these measures between the low-dose stress acquisition and high-dose rest acquisition in a one-day stress-rest protocol has not been established. We assessed the reproducibility of gated volumetric indices between stress and rest and the normal variation in ungated TID ratio for a one-day stress-rest 99mTc-tetrofosmin protocol. METHODS: Two thousand and one hundred and fifty eight (2158) 99mTc-tetrofosmin MPS patient studies were analyzed retrospectively. Studies were excluded for incomplete data, significant technical difficulties, or (for gated analysis but not for analysis of TID ratio) if the LV EF was > 75%. An analysis of gated data was undertaken to establish the reproducibility of ventricular volumes and EF between stress and rest scans. Ungated volume data were analyzed to determine the confidence limits of TID ratio according to ventricular volume. RESULTS: Gated data were analyzed for 621 patients without inducible hypoperfusion. Mean EF at rest was slightly higher than after stress (62.4% ± 10.3% vs 61.2% ± 10.4%, P < 0.001), and the standard deviation of the difference was 5.2% (95% CI 4.9% to 5.5%). Ungated volumes were available for 992 non-ischaemic patients. The upper 95% CI for TID ratio was 1.23. This increased from 1.20 to 1.37 between the highest and lowest deciles of rest ungated volume. CONCLUSION: Using a one-day stress-rest 99mTc-tetrofosmin protocol, a fall in LV EF between rest and stress of > 11.6% or a TID ratio of > 1.23 is likely to be clinically reliable. The upper limit of normal for TID ratio needs to be increased for patients with small LV chamber volumes.
引用
- Camm CF, Emery A, Rose-Innes E, et al. How variable are the volumetric measurements from gated perfusion SPECT when a one-day stress-rest protocol is used? J Nucl Cardiol. 2018. PMID: 29546491. doi:10.1007/s12350-018-1253-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。