文献速递肿瘤 PET/CT

肺癌患者18F-FDG PET显像中三参数动力学模型分析与标准Patlak分析比较

Comparison of three-parameter kinetic model analysis to standard Patlak's analysis in 18F-FDG PET imaging of lung cancer patients.
PubMed 文献 · EJNMMI Res · 2018-03-27

回顾性分析21例肺癌患者动态PET数据,比较线性Patlak分析与非线性三室三参数动力学模型分析(3P-KMA)所得Ki。3P-KMA的Ki较Patlak平均高6.0%,剔除8例kb>0患者后差异消失,Ki比值与kb强相关(R=0.801;P<0.001)。

要点

  • 3P-KMA所得Ki较Patlak平均高6.0%,一致性界限±17.1%(95%置信)。
  • 剔除8例kb>0患者后,两种方法Ki差异消失。
  • Ki比值(3P-KMA/Patlak)与kb强相关(R=0.801;P<0.001)。

核心结论

  • 3P-KMA与Patlak分析比较显示后者因将kb任意设为零而低估Ki,kb值越大Ki低估越明显。
  • 5P-KMA与Patlak分析比较未揭示该低估。
  • 作者建议需进一步研究以探讨3P-KMA在18F-FDG滞留可逆性高于肺癌病灶的其他组织中的效率。

研究设计与样本

  • 回顾性分析21例肺癌患者的动态PET数据,每例获得18F-FDG输入函数和组织时间-放射性曲线。
  • 输入函数用三指数衰减函数拟合,组织曲线用涉及拟合输入函数数据的解析公式拟合(11个数据点,范围注射后7.5–57.5分钟)。
  • 采用Bland-Altman分析比较Patlak分析与3P-KMA的Ki,并实施三室五参数KMA(5P-KMA)与Patlak分析及3P-KMA比较。

主要发现

  • 3P-KMA的Ki在整个患者系列中显著大于Patlak的Ki,平均+6.0%,一致性界限±17.1%(95%置信)。
  • 排除21例中8例kb>0患者后,该差异消失。
  • Ki比值(=3P-KMA/Patlak)与kb强相关(R=0.801;P<0.001)。
  • 3P-KMA与5P-KMA之间、5P-KMA与Patlak分析之间Ki无显著差异,一致性界限分别为±23.0%和±31.7%(95%置信)。

局限性

  • 作者建议需进一步研究以探讨3P-KMA在18F-FDG滞留可逆性高于肺癌病灶的其他组织中的效率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Patlak's graphical analysis can provide tracer net influx constant (Ki) with limitation of assuming irreversible tracer trapping, that is, release rate constant (kb) set to zero. We compared linear Patlak's analysis to non-linear three-compartment three-parameter kinetic model analysis (3P-KMA) providing Ki, kb, and fraction of free 18F-FDG in blood and interstitial volume (Vb). METHODS: Dynamic PET data of 21 lung cancer patients were retrospectively analyzed, yielding for each patient an 18F-FDG input function (IF) and a tissue time-activity curve. The former was fitted with a three-exponentially decreasing function, and the latter was fitted with an analytical formula involving the fitted IF data (11 data points, ranging 7.5-57.5 min post-injection). Bland-Altman analysis was used for Ki comparison between Patlak's analysis and 3P-KMA. Additionally, a three-compartment five-parameter KMA (5P-KMA) was implemented for comparison with Patlak's analysis and 3P-KMA. RESULTS: We found that 3P-KMA Ki was significantly greater than Patlak's Ki over the whole patient series, + 6.0% on average, with limits of agreement of ± 17.1% (95% confidence). Excluding 8 out of 21 patients with kb > 0 deleted this difference. A strong correlation was found between Ki ratio (=3P-KMA/Patlak) and kb (R = 0.801; P < 0.001). No significant difference in Ki was found between 3P-KMA versus 5P-KMA, and between 5P-KMA versus Patlak's analysis, with limits of agreement of ± 23.0 and ± 31.7% (95% confidence), respectively. CONCLUSIONS: Comparison between 3P-KMA and Patlak's analysis significantly showed that the latter underestimates Ki because it arbitrarily set kb to zero: the greater the kb value, the greater the Ki underestimation. This underestimation was not revealed when comparing 5P-KMA and Patlak's analysis. We suggest that further studies are warranted to investigate the 3P-KMA efficiency in various tissues showing greater 18F-FDG trapping reversibility than lung cancer lesions.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Laffon E, Calcagni ML, Galli G, et al. Comparison of three-parameter kinetic model analysis to standard Patlak's analysis in 18F-FDG PET imaging of lung cancer patients. EJNMMI Res. 2018. PMID: 29589224. doi:10.1186/s13550-018-0369-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。