本前瞻性先导研究纳入13例疑似心脏淀粉样变性患者,最终评估9例同时接受11C-PIB PET/CT与99mTc-抑肽酶闪烁显像者,比较影像结果与临床、病理及预后。9例中6例诊断为淀粉样变性,其中3例经心内膜心肌活检诊断为心脏淀粉样变性;这3例左心室壁11C-PIB摄取阳性者短期内心功能恶化或死于慢性心力衰竭急性加重。8例99mTc-抑肽酶摄取阳性者中6例左心室壁有淀粉样沉积,但11C-PIB结果不为阳性者症状保持稳定。

要点

  • 9例同时接受两种影像检查,6例诊断为淀粉样变性,3例经心内膜心肌活检诊断为心脏淀粉样变性。
  • 3例左心室壁11C-PIB摄取阳性者短期内心功能恶化或死于慢性心力衰竭急性加重。
  • 8例99mTc-抑肽酶摄取阳性者中6例左心室壁有淀粉样沉积,11C-PIB不为阳性者症状保持稳定。

核心结论

  • 在少量样本中,本研究显示心肌11C-PIB蓄积提示心脏淀粉样变性且预后不良。
  • 11C-PIB摄取可能与淀粉样物质向心脏进行性沉积有关,并可预测患者预后。

研究设计与样本

  • 前瞻性先导研究,连续考虑纳入13例疑似心脏淀粉样变性患者。
  • 参与者计划在2个月内接受系列11C-PIB PET/CT与99mTc-抑肽酶检查。
  • 最终评估9例同时接受两种影像检查的病例,并将影像结果与临床、病理结果及预后进行比较。

主要发现

  • 9例同时接受两种影像检查的患者中6例诊断为淀粉样变性,其中3例经心内膜心肌活检诊断为心脏淀粉样变性。
  • 3例左心室壁11C-PIB摄取阳性者表现为短期内心功能恶化进展或死于慢性心力衰竭急性加重。
  • 8例99mTc-抑肽酶摄取阳性者中6例左心室壁有淀粉样沉积,但11C-PIB结果不为阳性者症状保持稳定。

局限性

  • 原文在结论中自述为小样本(a small sample of subjects)。
  • 原文标题自述为先导研究(pilot study)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study was to investigate the significance of 11C-Pittsburgh B (PIB) PET/CT in patients with suspected cardiac amyloidosis compared with 99mTc-aprotinin scintigraphy. METHODS: Thirteen consecutive patients with suspected cardiac amyloidosis were considered for enrolment in this prospective pilot study. Participants were scheduled to undergo a series of 11C-PIB PET/CT and 99mTc-aprotinin within a 2-month period. Finally, we evaluated nine cases who underwent both imaging modalities, and compared imaging results with clinical and pathological results and prognosis. RESULTS: Six of the 9 patients who underwent both imaging modalities were diagnosed with amyloidosis, of whom 3 patients were diagnosed with cardiac amyloidosis from endomyocardial biopsy. These 3 patients with positive 11C-PIB uptake at the left ventricle wall showed worsening of cardiac function progressing in the short term or death caused by acute exacerbation of chronic heart failure. Six of 8 patients with positive uptake on 99mTc-aprotinin presented with amyloid deposition in the left ventricle wall, but symptoms remained stable if results of 11C-PIB were not positive. CONCLUSION: In a small sample of subjects, the present study showed that 11C-PIB accumulation in myocardium indicated cardiac amyloidosis with poor prognosis. Uptake of 11C-PIB may be related to progressive amyloid deposition to the heart and can predict patient prognosis.