文献速递放射性药物与辐射防护

使用99mTc-杜拉霉素对TNF诱导的全身炎症反应综合征中磷脂酰乙醇胺作为细胞死亡标志物进行无创全身成像

Noninvasive Whole-Body Imaging of Phosphatidylethanolamine as a Cell Death Marker Using 99mTc-Duramycin During TNF-Induced SIRS.
PubMed 文献 · J Nucl Med · 2018-02-01

本研究采用TNF诱导的全身炎症反应综合征(SIRS)无菌小鼠模型,用99mTc-杜拉霉素SPECT/CT纵向显像结合离体生物分布和TUNEL染色,评估损伤与细胞死亡的时空分布。结果显示TNF注射小鼠肺、肠、肝的示踪剂摄取较对照升高,且坏死他汀-1预处理可减轻致死性SIRS并降低肺摄取。

要点

  • 99mTc-杜拉霉素SPECT/CT可无创显示TNF诱导SIRS小鼠肺、肠、肝的损伤与细胞死亡时空 kinetics。
  • TNF注射后4小时肺、肠、肝摄取较对照升高,并持续至TNF后8小时。
  • 坏死他汀-1预处理可对抗致死性SIRS并降低TNF后8小时肺的99mTc-杜拉霉素摄取。

核心结论

  • 本研究表明,无创99mTc-杜拉霉素SPECT显像可用于表征TNF诱导SIRS期间易感组织中损伤和细胞死亡的时间与空间动力学,使其有助于对炎症和损伤相关疾病中的组织损伤进行整体全身评估。

研究设计与样本

  • 研究使用TNF诱导SIRS的无菌小鼠模型,C57BL/6J小鼠接受静脉注射鼠源TNF或溶媒,并用坏死他汀-1干预细胞死亡。
  • 溶媒或TNF处理后2小时,小鼠静脉注射99mTc-杜拉霉素35.44 ± 3.80 MBq。
  • 示踪剂注射后2、4、6小时进行静态全身99mTc-杜拉霉素SPECT/CT显像,用PMOD软件以容积感兴趣区分析定量示踪剂摄取,表达为SUVmean;末次扫描后进行离体生物分布验证SPECT数据,并进行TUNEL染色以将结果与细胞死亡关联。

主要发现

  • TNF注射小鼠较对照小鼠在TNF后4小时肺(0.55 ± 0.1 vs. 0.34 ± 0.05)、肠(0.75 ± 0.13 vs. 0.56 ± 0.1)、肝(1.03 ± 0.14 vs. 0.64 ± 0.04)的99mTc-杜拉霉素摄取升高,并持续显著升高至TNF后8小时。
  • 显像结果与离体γ计数结果一致。
  • TUNEL染色显示TNF注射小鼠肺和肠的组织损伤水平显著升高。
  • 坏死他汀-1预处理可对抗致死性SIRS并降低TNF后8小时肺的99mTc-杜拉霉素摄取(SUV,0.32 ± 0.1 vs. 0.51 ± 0.15)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Systemic inflammatory response syndrome (SIRS) is an inflammatory state affecting the whole body. It is associated with the presence of pro- and antiinflammatory cytokines in serum, including tumor necrosis factor (TNF). TNF has multiple effects and leads to cytokine production, leukocyte infiltration, and blood pressure reduction and coagulation, thereby contributing to tissue damage and organ failure. A sterile mouse model of sepsis, TNF-induced SIRS, was used to visualize the temporal and spatial distribution of damage in susceptible tissues during SIRS. For this, a radiopharmaceutical agent, 99mTc-duramycin, that binds to exposed phosphatidylethanolamine on dying cells was longitudinally visualized using SPECT/CT imaging. Methods: C57BL/6J mice were challenged with intravenous injections of murine TNF or vehicle, and necrostatin-1 was used to interfere with cell death. Two hours after vehicle or TNF treatment, mice received 99mTc-duramycin intravenously (35.44 ± 3.80 MBq). Static whole-body 99mTc-duramycin SPECT/CT imaging was performed 2, 4, and 6 h after tracer injection. Tracer uptake in different organs was quantified by volume-of-interest analysis using PMOD software and expressed as SUVmean After the last scan, ex vivo biodistribution was performed to validate the SPECT imaging data. Lastly, terminal deoxynucleotidyl-transferase-mediated deoxyuridine triphosphate nick-end labeling (TUNEL) staining was performed to correlate the obtained results to cell death. Results: An increased 99mTc-duramycin uptake was detected in mice injected with TNF, when compared with control mice, in lungs (0.55 ± 0.1 vs. 0.34 ± 0.05), intestine (0.75 ± 0.13 vs. 0.56 ± 0.1), and liver (1.03 ± 0.14 vs. 0.64 ± 0.04) 4 h after TNF and remained significantly elevated until 8 h after TNF. The imaging results were consistent with ex vivo γ-counting results. Significantly increased levels of tissue damage were detected via TUNEL staining in the lungs and intestine of mice injected with TNF. Interestingly, necrostatin-1 pretreatment conferred protection against lethal SIRS and reduced the 99mTc-duramycin uptake in the lungs 8 h after TNF (SUV, 0.32 ± 0.1 vs. 0.51 ± 0.15). Conclusion: This study demonstrated that noninvasive 99mTc-duramycin SPECT imaging can be used to characterize temporal and spatial kinetics of injury and cell death in susceptible tissues during TNF-induced SIRS, making it useful for global, whole-body assessment of tissue damage during diseases associated with inflammation and injury.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Delvaeye T, Wyffels L, Deleye S, et al. Noninvasive Whole-Body Imaging of Phosphatidylethanolamine as a Cell Death Marker Using 99mTc-Duramycin During TNF-Induced SIRS. J Nucl Med. 2018. PMID: 29419481. doi:10.2967/jnumed.117.205815

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。