文献速递神经核医学

日本健康对照者[123I]FP-CIT SPECT多中心数据库

Japanese multicenter database of healthy controls for [123I]FP-CIT SPECT.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2018-02-24

该多中心试验纳入8个中心的256名健康对照者(116男、140女,年龄30-83岁),共510组SPECT数据,采用Southampton法分析纹状体特异性结合比值(SBR)。未校正SBR按ChangACSC、CTACSC、ChangACNOSC、CTACNOSC、NOACNOSC顺序递减,NOACNOSC较ChangACSC低46%;校正后无散射校正条件下SBR几乎相等。年龄效应显著,SBR每十年下降6.3%。

要点

  • NOACNOSC的SBR较ChangACSC低46%,校正后无散射校正条件下SBR几乎相等。
  • 年龄效应显著,SBR每十年下降6.3%。
  • 30-39岁组女性SBR较男性高12.2%,该差异随年龄增长而减小,70-79岁组消失。

核心结论

  • 本研究提供了来自不同扫描仪、覆盖宽年龄范围且性别均衡的健康对照者[123I]FP-CIT SPECT大规模定量数据库。
  • 体模校准在无散射校正条件下有效统一了不同SPECT系统的数据。
  • 本研究收集的数据可能作为参考数据库。

研究设计与样本

  • 多中心试验,纳入8个中心的256名健康对照者(116名男性、140名女性;年龄范围30-83岁),共510组SPECT数据。
  • 图像重建包括无衰减或散射校正(NOACNOSC)、仅用Chang法衰减校正(ChangACNOSC)或X射线CT衰减校正(CTACNOSC)、以及同时进行散射和衰减校正的Chang法(ChangACSC)或X射线CT(CTACSC)。
  • 采用Southampton法分析SPECT图像,结局指标为纹状体特异性结合比值(SBR),并使用纹状体体模进行校准。

主要发现

  • 原始SBR按ChangACSC、CTACSC、ChangACNOSC、CTACNOSC、NOACNOSC顺序逐渐降低。
  • NOACNOSC的SBR较ChangACSC低46%。
  • 校正后SBR在无散射校正条件下几乎相等。
  • 年龄效应显著,SBR每十年下降6.3%。
  • 30-39岁组女性SBR较男性高12.2%,但该增加随年龄增长而减小,70-79岁组消失。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The aim of this multicenter trial was to generate a [123I]FP-CIT SPECT database of healthy controls from the common SPECT systems available in Japan. METHODS: This study included 510 sets of SPECT data from 256 healthy controls (116 men and 140 women; age range, 30-83 years) acquired from eight different centers. Images were reconstructed without attenuation or scatter correction (NOACNOSC), with only attenuation correction using the Chang method (ChangACNOSC) or X-ray CT (CTACNOSC), and with both scatter and attenuation correction using the Chang method (ChangACSC) or X-ray CT (CTACSC). These SPECT images were analyzed using the Southampton method. The outcome measure was the specific binding ratio (SBR) in the striatum. These striatal SBRs were calibrated from prior experiments using a striatal phantom. RESULTS: The original SBRs gradually decreased in the order of ChangACSC, CTACSC, ChangACNOSC, CTACNOSC, and NOACNOSC. The SBRs for NOACNOSC were 46% lower than those for ChangACSC. In contrast, the calibrated SBRs were almost equal under no scatter correction (NOSC) conditions. A significant effect of age was found, with an SBR decline rate of 6.3% per decade. In the 30-39 age group, SBRs were 12.2% higher in women than in men, but this increase declined with age and was absent in the 70-79 age group. CONCLUSIONS: This study provided a large-scale quantitative database of [123I]FP-CIT SPECT scans from different scanners in healthy controls across a wide age range and with balanced sex representation. The phantom calibration effectively harmonizes SPECT data from different SPECT systems under NOSC conditions. The data collected in this study may serve as a reference database.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Matsuda H, Murata M, Mukai Y, et al. Japanese multicenter database of healthy controls for [123I]FP-CIT SPECT. Eur J Nucl Med Mol Imaging. 2018. PMID: 29478082. doi:10.1007/s00259-018-3976-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。