文献速递心脏核医学

左束支传导阻滞患者与健康对照者电同步性与机械同步性的关系

Relationships between electrical and mechanical dyssynchrony in patients with left bundle branch block and healthy controls.
PubMed 文献 · J Nucl Cardiol · 2018-02-08

分析994例心肌灌注显像数据,其中43例符合左束支传导阻滞(LBBB)标准、24例为对照,用矢量心电图和门控心肌灌注显像相位分析评估电与机械同步性。QRS时限和舒张末期容积(EDV)与相位带宽独立相关,共解释其55%的变异;60%的LBBB患者存在显著机械性失同步。

要点

  • LBBB患者中60%存在显著机械性失同步,并非所有LBBB都伴机械性失同步。
  • QRS时限(r=0.69,P<.001)和EDV(r=0.59,P<.001)与相位带宽相关。
  • QRS时限和EDV独立关联相位带宽,共解释55%的变异。

核心结论

  • 尽管存在明显传导异常,LBBB并不总是伴随机械性失同步。
  • QRS时限和EDV解释了相位带宽变异的55%,且这两项参数在伴与不伴机械性失同步的LBBB病例间有统计学差异。

研究设计与样本

  • 分析994例患者的心肌灌注显像数据,其中43例符合LBBB标准、24例符合对照标准。
  • 以矢量心电图(VECG)表征电激活,以心电图门控心肌灌注显像相位分析评估左心室功能包括机械性失同步。

主要发现

  • QRS时限(r=0.69,P<.001)及若干其他VECG参数与代表机械性失同步的相位带宽(phaseBW)显著相关。
  • EDV(r=0.59,P<.001)、射血分数和收缩末期容积也与相位带宽相关。
  • QRS时限(β=0.47,P<.001)和EDV(β=0.36,P=.001)独立关联相位带宽,共解释其55%的变异。
  • 60%的LBBB患者存在显著机械性失同步;这些患者QRS时限更宽(159 vs 147 ms,P=.013)、EDV更大(144 vs 94 mL,P=.008)。
  • LBBB患者中机械性失同步的截断值为QRS时限≥165 ms和EDV≥109 mL。

关键数值与推荐

  • LBBB患者中机械性失同步的截断值:QRS时限≥165 ms、EDV≥109 mL。
  • 伴机械性失同步的LBBB患者QRS时限159 ms vs 不伴者147 ms(P=.013)。
  • 伴机械性失同步的LBBB患者EDV 144 mL vs 不伴者94 mL(P=.008)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Abnormal electrical activation may cause dyssynchronous left ventricular (LV) contraction. In this study, we characterized and analyzed electrical and mechanical dyssynchrony in patient with left bundle branch block (LBBB) and healthy controls. METHODS: Myocardial perfusion imaging (MPI) data from 994 patients were analyzed. Forty-three patient fulfilled criteria for LBBB and 24 for controls. Electrical activation was characterized with vector electrocardiography (VECG) and LV function including mechanical dyssynchrony with ECG-gated MPI phase analysis. RESULTS: QRS duration (QRSd; r = 0.69, P < .001) and a few other VECG parameters correlated significantly with phase bandwidth (phaseBW) representing mechanical dyssynchrony. End-diastolic volume (EDV; r = 0.59, P < .001), ejection fraction and end-systolic volume correlated also with phaseBW. QRSd (β = 0.47, P < .001) and EDV (β = 0.36, P = .001) were independently associated with phaseBW explaining 55% of its variation. Sixty percent of patients with LBBB had significant mechanical dyssynchrony. Those patients had wider QRSd (159 vs 147 ms, P = .013) and larger EDV (144 vs 94 mL, P = .008) than those with synchronous LV contraction. Cut-off values for mechanical dyssynchrony seen in patients with LBBB were QRSd ≥ 165 ms and EDV ≥ 109 mL. CONCLUSIONS: Despite obvious conduction abnormality, LBBB is not always accompanied by mechanical dyssynchrony. QRSd and EDV explained 55% of variation seen in phaseBW. These two parameters were statistically different between LBBB cases with and without mechanical dyssynchrony.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Sillanmäki S, Lipponen JA, Tarvainen MP, et al. Relationships between electrical and mechanical dyssynchrony in patients with left bundle branch block and healthy controls. J Nucl Cardiol. 2018. PMID: 29423906. doi:10.1007/s12350-018-1204-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。