CT衰减校正提高铊-201心肌灌注单光子发射计算机断层成像的诊断准确性

Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction.
PubMed 文献 · J Nucl Cardiol · 2018-02-26

该研究纳入108例连续接受铊-201心肌灌注显像并在3个月内行冠状动脉造影的患者,评估CT衰减校正的诊断效能。CT衰减校正使患者水平的曲线下面积从0.77提高至0.84(P=0.037),主要因特异性从0.57提高至0.78(P=0.013),敏感性无显著差异(0.79 vs 0.82,P=0.75)。作者认为CT衰减校正应作为铊-201心肌灌注显像的常规临床实践。

要点

  • CT衰减校正使患者水平AUC从0.77提高至0.84(P=0.037)。
  • 特异性从0.57提高至0.78(P=0.013),敏感性无显著差异(0.79 vs 0.82,P=0.75)。
  • 肥胖患者、男性患者及右冠状动脉病变者获益更明显。

核心结论

  • CT衰减校正主要通过提高特异性显著改善铊-201心肌灌注显像的诊断效能,在肥胖和男性患者中改善更显著。
  • 作者认为CT衰减校正应作为铊-201心肌灌注显像的常规临床实践。

研究设计与样本

  • 连续纳入108例接受铊-201心肌灌注显像并在3个月内行冠状动脉造影的患者。
  • 以敏感性、特异性和受试者工作特征曲线分析评估诊断效能,并按性别和肥胖进行亚组分析。

主要发现

  • CT衰减校正使患者水平曲线下面积从0.77提高至0.84(P=0.037)。
  • CT衰减校正使特异性从0.57提高至0.78(P=0.013),敏感性无显著差异(0.79 vs 0.82,P=0.75)。
  • 亚组分析中CT衰减校正对肥胖受试者、男性及右冠状动脉病变最有帮助。
  • 结论指出CT衰减校正的改善在肥胖患者和男性患者中显著更大。

临床怎么用

  • 作者认为CT衰减校正应作为铊-201心肌灌注显像的常规临床实践。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The benefits of attenuation correction (AC) in technetium-99m myocardial perfusion imaging (MPI) have been well established. However, the value of thallium (Tl-201) AC and routine computed tomography AC (CTAC) were less well established. The aims of this study were to evaluate the diagnostic performance of thallium (Tl-201) MPI with additional CTAC and to determine which participants would benefit most. METHODS AND RESULTS: A total of 108 consecutive patients who underwent Tl-201 MPI and received coronary angiography within 3 months were enrolled. Diagnostic performance was determined by sensitivity, specificity, and receiver operating characteristic curve analysis. Subgroup analyses were performed using gender and obesity. CTAC improved the area under the curve (0.84 vs. 0.77, P = 0.037 at patient level), primarily due to a significant improvement in specificity (0.78 vs. 0.57, P = 0.013) and no significant difference in sensitivity (0.79 vs. 0.82, P = 0.75). In subgroup analysis, CTAC was most helpful in obese subjects, men, and especially right coronary artery lesions. CONCLUSIONS: CTAC significantly improved diagnostic performance primarily by increasing the specificity, and the improvements were significantly greater in obese patients and male patients. These findings suggest that CTAC should be applied to Tl-201 MPI as routine clinical practice.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Huang JY, Yen RF, Lee WC, et al. Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction. J Nucl Cardiol. 2018. PMID: 29484543. doi:10.1007/s12350-018-1230-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。