使用11C-乙酸PET测量心肌氧化代谢、血流和外在效率的可重复性与重现性

Repeatable and reproducible measurements of myocardial oxidative metabolism, blood flow and external efficiency using 11C-acetate PET.
PubMed 文献 · J Nucl Cardiol · 2018-02-16

本研究在20例稳定射血分数降低的心力衰竭患者中,于基线和随访(间隔47±22天)时进行动态11C-乙酸PET扫描,由两名设盲观察者用FlowQuant®评估心肌氧耗量、心肌外在效率、做功代谢指数和心肌血流的重测可重复性及观察者内/间重现性。结果显示MEE和WMI的重测相关性和可重复性优于MVO2,所有观察者内/间相关性极佳(ICC=0.95-0.99),重现性值(CR=3%-6%)显著低于重测可重复性值(22%-54%,P<0.001),且使用较新PET-CT扫描仪时所有参数的可重复性均改善。

要点

  • 11C-乙酸PET测量的WMI和MEE表现出极佳的重测可重复性和操作者重现性。
  • 所有观察者内/间相关性极佳(ICC=0.95-0.99),重现性值(CR=3%-6%)显著低于重测可重复性值(22%-54%,P<0.001)。
  • 与旧式仅PET设备相比,使用较新PET-CT扫描仪时所有参数的可重复性均改善。

核心结论

  • 11C-乙酸PET测量的WMI和MEE表现出极佳的重测可重复性和操作者重现性。
  • 较新PET-CT扫描仪可能更适合用于心脏效率的纵向追踪。

研究设计与样本

  • 在20例稳定射血分数降低的心力衰竭患者中,于基线和随访(间隔47±22天)时进行动态11C-乙酸PET扫描。
  • 两名设盲观察者使用FlowQuant®评估11C-乙酸示踪剂摄取和清除率的重测可重复性及观察者内和观察者间重现性,用于测量心肌氧耗量(MVO2)、心肌外在效率(MEE)、做功代谢指数(WMI)和心肌血流。
  • 使用组内相关系数(ICC)和Bland-Altman可重复性系数(CR)评估重现性和可重复性。

主要发现

  • MEE和WMI的重测相关性和可重复性优于MVO2。
  • 所有观察者内和观察者间相关性极佳(ICC=0.95-0.99)。
  • 重现性值(CR=3%-6%)显著低于重测可重复性值(22%-54%,P<0.001)。
  • 与旧式仅PET设备相比,使用较新PET-CT扫描仪时所有参数的可重复性均改善。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Non-invasive approaches to investigate myocardial efficiency can help track the progression of heart failure (HF). This study evaluates the repeatability and reproducibility of 11C-acetate positron emission tomography (PET) imaging of oxidative metabolism. METHODS AND RESULTS: Dynamic 11C-acetate PET scans were performed at baseline and followup (47 ± 22 days apart) in 20 patients with stable HF with reduced ejection fraction. Two observers blinded to patients' clinical data used FlowQuant® to evaluate test-retest repeatability, as well as intra- and inter-observer reproducibility of 11C-acetate tracer uptake and clearance rates, for the measurement of myocardial oxygen consumption (MVO2), myocardial external efficiency (MEE), work metabolic index (WMI), and myocardial blood flow. Reproducibility and repeatability were evaluated using intra-class-correlation (ICC) and Bland-Altman coefficient-of-repeatability (CR). Test-retest correlations and repeatability were better for MEE and WMI compared to MVO2. All intra- and inter-observer correlations were excellent (ICC = 0.95-0.99) and the reproducibility values (CR = 3%-6%) were significantly lower than the test-retest repeatability values (22%-54%, P < 0.001). Repeatability was improved for all parameters using a newer PET-computed tomography (CT) scanner compared to older PET-only instrumentation. CONCLUSION: 11C-acetate PET measurements of WMI and MEE exhibited excellent test-retest repeatability and operator reproducibility. Newer PET-CT scanners may be preferred for longitudinal tracking of cardiac efficiency.