文献速递肿瘤 PET/CT放射性药物与辐射防护

使用微波辐射测量法和18F-FDG PET/CT测量棕色脂肪组织活性

Measurement of Brown Adipose Tissue Activity Using Microwave Radiometry and 18F-FDG PET/CT.
PubMed 文献 · J Nucl Med · 2018-02-09

本研究在19名接受寒冷干预的健康受试者中评估微波辐射测量系统无创评估活化与非活化棕色脂肪组织(BAT)及正常组织温度的操作特性,并与18F-FDG PET/CT对比。PET/CT在11/19名受试者中识别出BAT活性信号;在11名BAT活性受试者中的10名,寒冷研究中位于PET/CT活性BAT区域的测量点辐射测量值适度但显著高于非活性区域测量点(P < 0.01)。结论认为被动微波辐射测量可行,经大幅改进后有潜力无需放射性示踪剂注射即可无创检测活性棕色脂肪组织。

要点

  • PET/CT在11/19名受试者中识别出符合BAT活性的信号增高。
  • 11名BAT活性受试者中10名寒冷研究时活性区域测量点辐射测量值显著高于非活性点(P < 0.01)。
  • BAT最大化期间活性点平均辐射测量值为33.2°C ± 1.5°C,非活性点为32.7°C ± 1.3°C(P < 0.01)。

核心结论

  • 被动微波辐射测量被证明是可行的,经大幅改进后有潜力无需放射性示踪剂注射即可无创检测活性棕色脂肪组织。

研究设计与样本

  • 对19名接受寒冷干预以最大化BAT活性的参与者序贯进行微波辐射测量和18F-FDG PET/CT。
  • 寒冷干预为参与者坐在凉爽房间中间歇将双脚放在冰块上。
  • PET/CT定性显示BAT活性的参与者接受BAT最小化方案(暴露于温暖房间并给予20 mg普萘洛尔)后再次用两种方法扫描。
  • 在温暖和寒冷干预期间,PET/CT成像前每5分钟进行一次辐射测量,持续2小时。
  • 在参与者上半身绘制15-20个点的网格(每个点收集数据),并拍照以与PET/CT图像比较。

主要发现

  • PET/CT在19名参与者中的11名识别出符合BAT活性的信号增高。
  • 在11名有活性BAT的参与者中的10名,寒冷研究期间收集的辐射测量值在位于PET/CT活性BAT区域的点上适度但显著高于未显示BAT活性的点(P < 0.01)。
  • 这一差异在温暖研究期间减弱:11名参与者中的7名显示同一组点之间的辐射测量值无显著差异。
  • BAT最大化期间收集的平均辐射测量结果在 designated 为活性的点上为33.2°C ± 1.5°C,在 designated 为非活性的点上为32.7°C ± 1.3°C(P < 0.01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The aim of this study was to evaluate the operating characteristics of a microwave radiometry system in the noninvasive assessment of activated and nonactivated brown adipose tissue (BAT) and normal-tissue temperatures, reflecting metabolic activity in healthy human subjects. The radiometry data were compared with 18F-FDG PET/CT images in the same subjects. Methods: Microwave radiometry and 18F-FDG PET/CT were sequentially performed on 19 participants who underwent a cold intervention to maximize BAT activation. The cold intervention involved the participants' intermittently placing their feet on an ice block while sitting in a cool room. Participants exhibiting BAT activity qualitatively on PET/CT were scanned again with both modalities after undergoing a BAT minimization protocol (exposure to a warm room and a 20-mg dose of propranolol). Radiometry was performed every 5 min for 2 h before PET/CT imaging during both the warm and the cold interventions. A grid of 15-20 points was drawn on the participant's upper body (data were collected at each point), and a photograph was taken for comparison with PET/CT images. Results: PET/CT identified increased signal consistent with BAT activity in 11 of 19 participants. In 10 of 11 participants with active BAT, radiometry measurements collected during the cold study were modestly, but significantly, higher on points located over areas of active BAT on PET/CT than on points not exhibiting BAT activity (P < 0.01). This difference lessened during the warm studies: 7 of 11 participants showed radiometry measurements that did not differ significantly between the same set of points. The mean radiometry result collected during BAT maximization was 33.2°C ± 1.5°C at points designated as active and 32.7°C ± 1.3°C at points designated as inactive (P < 0.01). Conclusion: Passive microwave radiometry was shown to be feasible and, with substantial improvements, has the potential to noninvasively detect active brown adipose tissue without a radiotracer injection.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Crandall JP, O JH, Gajwani P, et al. Measurement of Brown Adipose Tissue Activity Using Microwave Radiometry and 18F-FDG PET/CT. J Nucl Med. 2018. PMID: 29439011. doi:10.2967/jnumed.117.204339

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。