文献速递心脏核医学

高敏肌钙蛋白T与其他生物标志物相比在心肌缺血中的相关性更强

Stronger correlation with myocardial ischemia of high-sensitivity troponin T than other biomarkers.
PubMed 文献 · J Nucl Cardiol · 2018-01-29

研究前瞻性纳入71例行运动负荷心肌灌注显像的患者,比较缺血组与非缺血组运动前后IMA、NPY、NT-proBNP和hsTnT水平。仅hsTnT在两组间有显著差异,缺血组运动前后均更高,尤其在Bruce方案较高阶段差异更明显。

要点

  • 71例患者中26例(36.6%)负荷显像示可逆性摄取减低,符合心肌缺血。
  • 缺血组hsTnT运动前0.0075 ng/ml vs 非缺血组0.0050 ng/ml(P=0.023)。
  • 缺血组hsTnT运动后0.0085 vs 非缺血组0.0050(P=0.015),其余标志物无显著差异。

核心结论

  • IMA、NPY和NT-proBNP可能无法检测轻微缺血性心肌损伤,而血清hsTnT不仅对心肌梗死、也对较轻缺血具有更强检测能力。
  • 作者认为需要更大队列的进一步研究以更好界定hsTnT作为心肌缺血筛查工具的作用。

研究设计与样本

  • 前瞻性分析2011年12月至2012年6月因临床怀疑心肌缺血行运动负荷心肌灌注显像(MPS)的患者。
  • 共纳入71例患者(男56例、女15例),平均年龄61±12岁;运动前及达到最大负荷后3分钟内采血检测IMA、NPY、NT-proBNP和hsTnT。

主要发现

  • 26例患者(36.6%)负荷MPS图像示摄取减低、静息恢复正常,符合心肌缺血。
  • 缺血组与非缺血组间仅hsTnT水平有显著差异,缺血组运动前为0.0075 ng/ml vs 非缺血组0.0050 ng/ml(P=0.023)。
  • 缺血组运动后hsTnT为0.0085 vs 非缺血组0.0050(P=0.015)。
  • 差异在Bruce方案较高阶段更明显(运动持续时间>9.05分钟,P<0.017)。
  • IMA、NPY和NT-proBNP在两组间各时间点均无显著差异。

局限性

  • 作者在结论中提出需要更大队列的进一步研究,以更好界定hsTnT作为心肌缺血筛查工具的作用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Acute myocardial infarction (AMI) is considered a major cause of death and disability. Myocardial perfusion scintigraphy (MPS) as a non-invasive diagnostic imaging procedure and certain biomarkers associated with myocardial ischemia (ISCH), such as ischemia-modified albumin (IMA), neuropeptide Y (NPY), N-terminal pro b-type natriuretic peptide (NT-proBNP), and high-sensitivity troponin T (hsTnT) could probably aid in the detection of myocardial infarction. METHODS: Between December 2011 and June 2012, we prospectively analyzed patients who underwent a MPS study with the clinical question of myocardial ISCH. An exercise test was performed along with a MPS. Blood was drawn from the patients before exercise and the within 3 minutes from achieving maximum load and was analyzed for the aforementioned biomarkers. RESULTS: A total of 71 patients (56 men and 15 women) were enrolled with a mean age of 61 ± 12 years. Twenty-six patients (36.6%) showed reduced uptake on stress MPS images that normalized at rest, a finding consistent with ISCH. Between ISCH and non-ISCH groups, only hsTnT levels showed a significant difference with the highest levels pertaining to the former group both before (0.0075 ng/ml vs 0.0050 ng/ml, P = 0.023) and after stress exercise (0.0085 vs 0.0050, P = 0.015). The most prominent differences were seen in higher stages of the Bruce protocol (stress duration > 9.05 minutes - P < 0.017). None of the IMA, NPY, and NP-pro BNP showed significant differences in time between the two groups. CONCLUSIONS: Although IMA, NPY, and NT-pro BNP may not detect minor ischemic myocardial insults, serum hsTnT holds a greater ability of detecting not only myocardial infarction but also less severe ischemia. Further studies with larger cohorts of patients are warranted in order to better define the role of hsTnT as a screening tool for myocardial ischemia.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Pipikos T, Kapelouzou A, Tsilimigras DI, et al. Stronger correlation with myocardial ischemia of high-sensitivity troponin T than other biomarkers. J Nucl Cardiol. 2018. PMID: 29380285. doi:10.1007/s12350-018-1199-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。