基于体积的FDG PET/CT葡萄糖代谢分析:抑制生理性心肌摄取的最佳阈值与条件
该回顾性研究纳入190例患者,以血池SUVmean×1.5为阈值定义心脏代谢体积(CMV),评估降主动脉与左心室腔血池测量的可重复性及心肌生理性摄取与临床因素的关系。降主动脉血池SUVmean可重复性高且与CMV无显著相关,空腹超过18小时与CMV=0独立相关。
要点
- 降主动脉血池SUVmean的组间可重复性高(ICC=0.93),适合用于确定体积分析阈值。
- 空腹不足18小时的患者CMV显著高于空腹超过18小时者(49.7 ± 73.2 vs. 18.0 ± 53.8 mL,P = 0.0013)。
- 多因素分析显示仅空腹超过18小时与CMV=0独立相关。
核心结论
- 降主动脉适合用于确定基于体积分析的阈值,空腹时间与心脏FDG摄取显著相关。
研究设计与样本
- 回顾性分析190例患者的FDG PET/CT数据,CMV定义为阈值(血池SUVmean×1.5)确定的边界内体积。
主要发现
- 降主动脉血池SUVmean的组间可重复性高(r = 0.86,ICC = 0.93,P < 0.0001)。
- 左心室腔血池SUVmean的组间可重复性高(r = 0.87,ICC = 0.90,P < 0.0001),但与CMV显著相关(P = 0.0002,r = 0.26)。
- 空腹不足18小时的患者CMV显著高于空腹超过18小时者(49.7 ± 73.2 vs. 18.0 ± 53.8 mL,P = 0.0013)。
- 多因素分析显示仅空腹超过18小时与CMV=0独立相关。
关键数值与推荐
- CMV阈值定义为血池SUVmean×1.5。
- 空腹超过18小时与CMV=0独立相关。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: FDG PET/CT plays a significant role in the diagnosis of inflammatory heart diseases and cardiac tumors. We attempted to determine the optimal FDG uptake threshold for volume-based analyses and to evaluate the relationship between the myocardial physiological uptake volume in FDG PET and several clinical factors. METHODS: A total of 190 patients were retrospectively analyzed. The cardiac metabolic volume (CMV) was defined as a volume within the boundary determined by a threshold (SUVmean of blood pool × 1.5). RESULTS: The SUVmean of the blood pool measured in the descending aorta (DA) (r = 0.86, intraclass correlation coefficient [ICC] = 0.93, P < 0.0001) and that in the left ventricle (LV) cavity (r = 0.87, ICC = 0.90, P < 0.0001) showed high inter-operator reproducibility. However, the SUVmean in the LV cavity showed a significant correlation with the CMV (P = 0.0002, r = 0.26). The CMV in the patients who fasted < 18 hours were significantly higher (49.7 ± 73.2 vs. 18.0 ± 53.8 mL, P = 0.0013) compared to the patients with > 18-hour fasting. The multivariate analysis demonstrated that only the fasting period > 18 hours was independently associated with CMV = 0. CONCLUSION: Our findings revealed that the DA is suitable to decide the threshold for the volume-based analysis. The fasting time was significantly associated with the cardiac FDG uptake.
引用
- Manabe O, Kroenke M, Aikawa T, et al. Volume-based glucose metabolic analysis of FDG PET/CT: The optimum threshold and conditions to suppress physiological myocardial uptake. J Nucl Cardiol. 2017. PMID: 29243072. doi:10.1007/s12350-017-1122-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。