文献速递肿瘤 PET/CT心脏核医学

18F-FDG PET/CT用于颈动脉大斑块炎症的定量评估

18F-FDG PET/CT for the quantification of inflammation in large carotid artery plaques.
PubMed 文献 · J Nucl Cardiol · 2017-12-05

本研究纳入44例颈内动脉粥样硬化性狭窄≥70%的患者,行18F-FDG PET/CT并探索颈动脉斑块摄取的不同定量方法,其中30例斑块在动脉内膜切除术后行组织学评估。结果显示,不同摄取定量值之间显著相关(r=0.57-0.99,P<0.001),有无血池本底校正的方法与组织学炎症程度均呈相似的中等程度相关(r=0.44-0.59,P<0.02)。结论认为,在大狭窄性颈动脉斑块中,18F-FDG摄取反映组织学评估的炎症状态,增加PET层数或本底校正未改变相关性。

要点

  • 44例颈内动脉狭窄≥70%患者行18F-FDG PET/CT,30例斑块经内膜切除术后组织学评估。
  • 不同摄取定量值间显著相关(r=0.57-0.99,P<0.001)。
  • 有无血池本底校正的方法与组织学炎症均呈相似中等相关(r=0.44-0.59,P<0.02)。

核心结论

  • 在大狭窄性颈动脉斑块中,18F-FDG摄取反映组织学评估的炎症状态。
  • 增加PET层数或进行本底校正未改变与组织学炎症的相关性。

研究设计与样本

  • 44例颈内动脉粥样硬化性狭窄≥70%的患者接受18F-FDG PET/CT检查。
  • 采集所有含斑块层面的最大标准化摄取值(SUVmax),计算单层最高值及多层均值,分别在有和无血池本底校正(减影法cSUV或除法法靶本比TBR)下获得。
  • 动脉内膜切除术后对30个斑块进行组织学评估。

主要发现

  • CT上斑块长度为6-32 mm。
  • 斑块18F-FDG摄取:未校正SUV为1.15-2.66,TBR为1.16-3.19,cSUV为0.20-1.79。
  • 不同摄取定量值之间显著相关(r=0.57-0.99,P<0.001)。
  • 有和无血池本底校正的方法与组织学评估的炎症程度均呈相似的中等程度相关(r=0.44-0.59,P<0.02)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is currently no consensus on the methodology for quantification of 18F-FDG uptake in inflammation in atherosclerosis. In this study, we explore different methods for quantification of 18F-FDG uptake in carotid atherosclerotic plaques and correlate the uptake values to histological assessments of inflammation. METHODS AND RESULTS: Forty-four patients with atherosclerotic stenosis ≥70% of the internal carotid artery underwent 18F-FDG PET/CT. Maximum standardized uptake values (SUVmax) from all plaque-containing slices were collected. SUVmax for the single highest and the mean of multiple slices with and without blood background correction (by subtraction (cSUV) or by division (target-to-background ratio (TBR)) were calculated. Following endarterectomy 30 plaques were assessed histologically. The length of the plaques at CT was 6-32 mm. The 18F-FDG uptake in the plaques was 1.15-2.66 for uncorrected SUVs, 1.16-3.19 for TBRs, and 0.20-1.79 for cSUVs. There were significant correlations between the different uptake values (r = 0.57-0.99, P < 0.001). Methods with and without blood background correction showed similar, moderate correlations to the amount of inflammation assessed at histology (r = 0.44-0.59, P < 0.02). CONCLUSIONS: In large stenotic carotid plaques, 18F-FDG uptake reflects the inflammatory status as assessed at histology. Increasing number of PET slices or background correction did not change the correlation.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Johnsrud K, Skagen K, Seierstad T, et al. 18F-FDG PET/CT for the quantification of inflammation in large carotid artery plaques. J Nucl Cardiol. 2017. PMID: 29209949. doi:10.1007/s12350-017-1121-7