冠状动脉CT血管造影衍生的冠状动脉对比剂充盈度检测缺血的诊断准确性:与单光子发射计算机断层扫描的首次验证
该回顾性研究纳入72例接受混合CCTA/SPECT心肌灌注显像且至少存在一支冠状动脉狭窄的患者,评估CCTA衍生的校正对比剂充盈度下降(CCO decrease)和跨腔衰减梯度(TAG)预测SPECT MPI所评估缺血的准确性。在127支CCTA显示狭窄的血管中,38支(30%)导致其供血心肌缺血。CCO decrease预测缺血的AUC为0.707,TAG的AUC为0.469。结论认为CCO decrease可预测SPECT MPI中的缺血,而TAG不能;CCO decrease的阴性预测值为85%,可能在冠状动脉狭窄患者的诊断流程中具有临床意义。
要点
- CCO decrease预测缺血的AUC为0.707,敏感性74%、特异性64%、阴性预测值85%、阳性预测值47%、准确性67%。
- TAG预测缺血的AUC为0.469。
- 在127支CCTA显示狭窄的血管中,38支(30%)导致其供血心肌缺血。
核心结论
- CCTA衍生的CCO decrease可预测SPECT MPI中的缺血,而TAG不能。
- CCO decrease的阴性预测值为85%,可能在冠状动脉狭窄患者的诊断流程中具有临床意义。
研究设计与样本
- 回顾性研究,纳入72例接受混合CCTA/SPECT MPI且至少存在一支冠状动脉狭窄的患者。
- 评估CCTA衍生的CCO decrease和TAG预测SPECT MPI所评估缺血的准确性。
- 共分析127支CCTA显示狭窄的血管。
主要发现
- 在127支CCTA显示狭窄的血管中,38支(30%)导致其供血心肌缺血。
- CCO decrease预测缺血的AUC为0.707,敏感性74%、特异性64%、阴性预测值85%、阳性预测值47%、准确性67%。
- TAG预测缺血的AUC为0.469。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Estimation of functional relevance of a coronary stenosis by fractional flow reserve (FFR) from coronary computed tomography angiography (CCTA) has recently provided encouraging results. Due to its limited availability, the corrected contrast opacification (CCO) decrease and the transluminal attenuation gradient (TAG) were suggested as less complex alternatives. The aim of the present study was to assess the accuracy of CCO decrease and TAG to predict ischemia as assessed by single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). RESULTS: This retrospective study included 72 patients who underwent hybrid CCTA/SPECT MPI with at least one coronary artery stenosis. Of 127 vessels with a coronary stenosis in CCTA, 38 (30%) were causing ischemia in its subtending myocardium. The area under the curve (AUC) for CCO decrease to predict ischemia was 0.707 with sensitivity, specificity, negative predictive value, positive predictive value, and accuracy of 74, 64, 85, 47, and 67%, respectively. For TAG, the AUC was 0.469. CONCLUSIONS: CCTA-derived CCO decrease but not TAG predicts ischemia in SPECT MPI. The negative predictive value of CCO decrease of 85% may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.
引用
- Benz DC, Mikulicic F, Gräni C, et al. Diagnostic accuracy of coronary opacification derived from coronary computed tomography angiography to detect ischemia: first validation versus single-photon emission computed tomography. EJNMMI Res. 2017. PMID: 29178006. doi:10.1186/s13550-017-0342-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。