该 Meta 分析检索 1990 年 1 月至 2017 年 4 月多个数据库,纳入 13 项研究共 537 例患者,评估 18F-FDG PET/CT 诊断感染性心内膜炎的准确性。汇总灵敏度为 76.8%(95%CI 71.8-81.4%),汇总特异度为 77.9%(95%CI 71.9-83.2%);对人工瓣膜心内膜炎灵敏度为 80.5%(95%CI 74.1-86.0%)、特异度为 73.1%(95%CI 63.8-81.2%)。全身 PET/CT 在 17% 的患者中发现额外心外感染灶。

要点

  • PET/CT 诊断感染性心内膜炎汇总灵敏度 76.8%、特异度 77.9%。
  • 人工瓣膜心内膜炎灵敏度 80.5%、特异度 73.1%。
  • 17% 患者全身 PET/CT 发现额外心外感染灶。

核心结论

  • PET/CT 是评估诊断困难感染性心内膜炎病例的有用辅助诊断工具,尤其适用于人工瓣膜心内膜炎。
  • PET/CT 还有可能检测到临床相关的心外感染灶、恶性肿瘤和其他炎症来源,从而有助于制定更合适的治疗方案和手术干预。

研究设计与样本

  • 检索 PubMed、Embase、Cochrane library、CINAHL、Web of Knowledge 和 www.clinicaltrials.gov,时间范围为 1990 年 1 月至 2017 年 4 月,纳入评估 PET/CT 诊断可能感染性心内膜炎准确性的研究。
  • 共纳入 13 项研究、537 例患者进行 Meta 分析。

主要发现

  • PET/CT 诊断感染性心内膜炎的汇总灵敏度为 76.8%(95%CI 71.8-81.4%;Q=39.9,P<0.01;I²=69.9%),汇总特异度为 77.9%(95%CI 71.9-83.2%;Q=44.42,P<0.01;I²=73.0%)。
  • 人工瓣膜心内膜炎诊断准确性提高,灵敏度为 80.5%(95%CI 74.1-86.0%;Q=25.5,P<0.01;I²=72.5%),特异度为 73.1%(95%CI 63.8-81.2%;Q=32.1,P<0.01;I²=78.2%)。
  • 全身 PET/CT 在 17% 的患者中发现额外心外感染灶。

局限性

  • 异质性 I²=69.9%(汇总灵敏度分析)。
  • 异质性 I²=73.0%(汇总特异度分析)。
  • 异质性 I²=72.5%(人工瓣膜心内膜炎灵敏度分析)。
  • 异质性 I²=78.2%(人工瓣膜心内膜炎特异度分析)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The current diagnosis of infective endocarditis (IE) is based on the modified Duke criteria, which has approximately 80% sensitivity for the diagnosis of native valve endocarditis (NVE), with lower sensitivity for the diagnosis of prosthetic valve endocarditis (PVE) and culture-negative endocarditis. There is preliminary evidence that 18F-FDG PET/CT is an adjunctive diagnostic test with high accuracy reported in small studies to date. We therefore performed a meta-analysis of studies evaluating the use of PET/CT in the diagnosis of IE to establish a more precise estimate of accuracy. METHODS: PubMed, Embase, Cochrane library, CINAHL, Web of Knowledge, and www.clinicaltrials.gov were searched from January 1990 to April 2017 for studies evaluating the accuracy of PET/CT for the evaluation of possible IE. RESULTS: We identified 13 studies involving 537 patients that were included in the meta-analysis. The pooled sensitivity of PET/CT for diagnosis of IE was 76.8% (95% CI 71.8-81.4%; Q = 39.9, P < 0.01; I2 = 69.9%) and the pooled specificity was 77.9% (95% CI 71.9-83.2%; Q = 44.42, P < 0.01; I2 = 73.0%). Diagnostic accuracy was improved for PVE with sensitivity of 80.5% (95% CI 74.1-86.0%; Q = 25.5, P < 0.01; I2 = 72.5%) and specificity of 73.1% (95% CI 63.8-81.2%; Q = 32.1, P < 0.01; I2 = 78.2%). Additional extracardiac foci of infection were found on 17% of patients on whole body PET/CT. CONCLUSION: PET/CT is a useful adjunctive diagnostic tool in the evaluation of diagnostically challenging cases of IE, particularly in prosthetic valve endocarditis. It also has the potential to detect clinically relevant extracardiac foci of infection, malignancy, and other sources of inflammation leading to more appropriate treatment regimens and surgical intervention.