镉锌碲成像评估左心室质量:与心脏磁共振的验证对照
研究对比了25例患者在CZT相机MPI与1.5T CMR上测量的左心室质量,CZT图像用4DM和ECTb两种软件定量。4DM与CMR均值无显著差异,ECTb较CMR和4DM显著偏高,两种软件与CMR相关性均极好、可重复性高,作者认为CZT图像评估左心室质量可行。
要点
- 25例患者在12±3周内完成CZT MPI与1.5T CMR检查。
- 左心室质量均值:CMR 151±44 g,4DM 151±43 g(与CMR无显著差异),ECTb 157±42 g(较CMR P<.001,较4DM P=.007)。
- 4DM与ECTb的可重复性组内相关系数分别为.98(95%CI .97-.99)和.98(95%CI .97-.99)。
核心结论
- 作者认为在CZT图像上评估左心室质量是可行的,与CMR显示出极好的一致性。
研究设计与样本
- 25例患者接受CZT相机MPI和1.5T扫描仪CMR检查,间隔12±3周。
- CZT图像左心室质量用4D-MSPECT(4DM)和Emory Cardiac Toolbox(ECTb)两种软件定量,CMR用MASS软件(Medis,Leiden,The Netherlands)定量。
主要发现
- 4DM与ECTb的左心室质量值高度可重复,组内相关系数分别为.98(95%CI .97-.99)和.98(95%CI .97-.99)。
- 左心室质量均值:CMR 151±44 g,4DM 151±43 g(与CMR相比P=NS),ECTb 157±42 g(与CMR相比P<.001;与4DM相比P=.007)。
- CMR与4DM(R2=.95;P<.001)及ECTb(R2=.98;P<.001)的左心室质量值均呈极好相关,一致性界限分别为-13.6%至+13.4%(4DM)和-5.6%至+14.1%(ECTb)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Single-photon emission computed tomography has shown relevant limitations in the quantification of left ventricular (LV) mass. We sought to compare the estimates of LV mass on Cadmium-Zinc-Telluride (CZT) myocardial perfusion imaging (MPI) as compared to cardiac magnetic resonance (CMR). METHODS AND RESULTS: Twenty-five patients underwent MPI on a CZT camera and CMR on a 1.5 T scanner within 12 ± 3 weeks. LV mass was quantified on CZT images using two softwares: 4D-MSPECT (4DM) and Emory Cardiac Toolbox (ECTb). LV mass by CMR was quantified using MASS software (Medis, Leiden, The Netherlands). LV mass values obtained with 4DM and ECTb were highly reproducible [intraclass correlation coefficients .98 (95% CI .97-.99), and .98 (95% CI 0.97-.99), respectively]. The mean LVM mass values were 151 ± 44 g on CMR, 151 ± 43 g with 4DM (P = NS vs CMR), and 157 ± 42 g with ECTb (P < .001 vs CMR; P = .007 vs 4DM) CZT images. There was an excellent correlation between LV mass values between CMR and both 4DM (R2 = .95; P < .001) and ECTb (R2 = .98; P < .001) with narrow limits of agreement (- 13.6% to + 13.4% for 4DM, and - 5.6% to + 14.1% for ECTb). CONCLUSIONS: The evaluation of LV mass is feasible on CZT images, showing excellent agreement with CMR.