回顾性评估117例前列腺根治术后生化复发且未接受激素治疗的患者,行68Ga-PSMA 11 PET/CT或PET/MRI,并与单独CT/MRI比较。PSMA-PET在85.5%患者中检出阳性病灶,在CT/MRI按RECIST 1.1无可疑病灶的67例中检出病灶,并使其中74.6%的治疗决策发生改变。

要点

  • PSMA-PET在生化复发患者中检出病灶的总体阳性率为85.5%,PSA≥2 ng/ml时检出率达100%。
  • PSMA-PET在CT/MRI无可疑病灶的67例中检出病灶,并使其中74.6%的治疗决策改变。
  • PSMA-PET改变了治疗决策的患者中,86%被考虑接受转移灶定向治疗。

核心结论

  • PSMA-PET显像对前列腺根治术后生化复发患者的复发灶检出具有高效能,即使在相对较低的PSA水平也能检出。
  • PSMA-PET在标准CT/MRI基础上增加显著信息,使相当数量患者的治疗策略发生改变。

研究设计与样本

  • 回顾性评估117例前列腺根治术后生化复发且未接受激素治疗的患者,于2014年5月至2017年1月间行68Ga-PSMA 11 PET/CT(n=46)或PET/MRI(n=71)。
  • 生化复发定义为PSA两次升高超过0.2 ng/ml。
  • 两名泌尿肿瘤影像专家分别独立阅片,结果以盲法序贯方式提交多学科肿瘤委员会以评估对决策的影响。

主要发现

  • 从根治术到生化复发的中位时间为36个月(IQR 16-72),69例(59%)患者接受过术后放疗,显像时中位PSA为1.04 ng/ml(IQR 0.58-1.87)。
  • 100例(85.5%)患者检出PSMA阳性病灶;PSA 0.2至<0.5 ng/ml时检出率为65%,0.5至<1 ng/ml为85.7%,1至<2 ng/ml为85.7%,≥2 ng/ml为100%。
  • 79%患者的PSMA阳性病灶经组织学(16%)、转移灶定向放疗后PSA下降(45%)或PET/MRI扩散加权成像额外信息(18%)证实。
  • 67例(57.3%)患者在MRI或CT上按RECIST 1.1无可疑对应病灶,PSMA-PET在其中检出病灶。
  • PSMA-PET使这67例中74.6%的治疗决策发生改变(p < 0.001),其中86%被考虑接受转移灶定向治疗。

关键数值与推荐

  • 生化复发定义:PSA两次升高超过0.2 ng/ml。
  • PSA 0.2至<0.5 ng/ml时PSMA-PET检出率为65%。
  • PSA 0.5至<1 ng/ml时PSMA-PET检出率为85.7%。
  • PSA 1至<2 ng/ml时PSMA-PET检出率为85.7%。
  • PSA≥2 ng/ml时PSMA-PET检出率为100%。

临床怎么用

  • 作者确认PSMA-PET显像对前列腺根治术后生化复发患者的复发灶检出具有高效能,即使PSA水平相对较低。
  • 作者指出PSMA-PET在标准CT/MRI基础上增加显著信息,使相当数量患者的治疗策略发生改变。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the diagnostic performance of [68Ga]Ga-PSMAHBED-CC conjugate 11 positron emission tomography (PSMA-PET) in the early detection of metastases in patients with biochemical recurrence (BCR) after radical prostatectomy (RP) for clinically non-metastatic prostate cancer, to compare it to CT/MRI alone and to assess its impact on further therapeutic decisions. MATERIAL AND METHODS: We retrospectively assessed 117 consecutive hormone-naïve BCR patients who had 68Ga-PSMA 11 PET/CT (n = 46) or PET/MRI (n = 71) between May 2014 and January 2017. BCR was defined as two PSA rises above 0.2 ng/ml. Two dedicated uro-oncological imaging experts (radiology/nuclear medicine) reviewed separately all images. All results were presented in a blinded sequential fashion to a multidisciplinary tumorboard in order to assess the influence of PSMA-PET imaging on decision-making. RESULTS: The median time from RP to BCR was 36 months (IQR 16-72). Overall, 69 (59%) patients received postoperative radiotherapy. Median PSA level at the time of imaging was 1.04 ng/ml (IQR 0.58-1.87). PSMA-positive lesions were detected in 100 (85.5%) patients. Detection rates were 65% for a PSA value of 0.2 to <0.5 ng/ml, 85.7% for 0.5 to <1, 85.7% for 1 to <2 and 100% for ≥2. PSMA-positive lesions could be confirmed by either histology (16%), PSA decrease in metastasis-directed radiotherapy (45%) or additional information in diffusion-weighted imaging when PET/MRI was performed (18%) in 79% of patients. PSMA-PET detected lesions in 67 patients (57.3%) who had no suspicious correlates according to the RECIST 1.1 criteria on MRI or CT. PSMA-PET changed therapeutic decisions in 74.6% of these 67 patients (p < 0.001), with 86% of them being considered for metastases-directed therapies. CONCLUSIONS: We confirm the high performance of PSMA-PET imaging for the detection of disease recurrence sites in patients with BCR after RP, even at relatively low PSA levels. Moreover, it adds significant information to standard CT/MRI, changing treatment strategies in a significant number of patients.