PubMed 文献 · Eur J Nucl Med Mol Imaging · 2017-10-26

研究纳入10例新诊断头颈癌患者,在放化疗前接受两次[18F]EF5 PET/CT(中位间隔7天)和一次[18F]FDG PET/CT,以肿瘤/肌肉摄取比(TMR)1.5为乏氧组织阈值。结果显示SUVmean、SUVmax和TMR的组内相关系数分别为0.81、0.85和0.87,相对可重复性系数分别为15%、17%和10%。结论认为治疗前一周内[18F]EF5 PET/CT可重复性高,可用于指导头颈癌乏氧靶向治疗干预。

要点

  • 10例头颈癌患者两次[18F]EF5 PET/CT中位间隔7天,SUVmean、SUVmax、TMR的组内相关系数为0.81、0.85、0.87。
  • 上述参数的相对可重复性系数分别为15%、17%和10%。
  • 重复扫描的肿瘤乏氧体积高度相关(Spearman r=0.94), pooled TMR平均差为0.03±0.20。

核心结论

  • 治疗前一周内[18F]EF5 PET/CT可重复性高,可用于指导头颈癌乏氧靶向治疗干预。

研究设计与样本

  • 研究纳入10例新诊断头颈癌患者,在放化疗前接受三次静态PET/CT:两次[18F]EF5(中位间隔7天)和一次[18F]FDG。
  • 在[18F]FDG图像上定义代谢活跃的原发肿瘤体积,并转移至配准的[18F]EF5图像进行可重复性分析。
  • 以注射[18F]EF5后3小时肿瘤/肌肉摄取比(TMR)1.5作为代表乏氧组织的阈值。

主要发现

  • 10对[18F]EF5 PET/CT图像中,SUVmean、SUVmax和TMR的组内相关系数分别为0.81、0.85和0.87。
  • SUVmean、SUVmax和TMR的相对可重复性系数分别为15%、17%和10%。
  • 重复扫描的肿瘤乏氧体积高度相关(Spearman秩相关检验r=0.94)。
  • 重复扫描间基于体素的TMR分析中,个体患者Pearson相关系数均值为0.65。
  • 汇总数据中TMR的平均差(±SD)为0.03±0.20。

关键数值与推荐

  • 以注射[18F]EF5后3小时TMR 1.5作为代表乏氧组织的阈值。

临床怎么用

  • 原文结论认为治疗前一周内[18F]EF5 PET/CT可重复性高,可用于指导头颈癌乏氧靶向治疗干预。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Hypoxia contributes to radiotherapy resistance and more aggressive behaviour of several types of cancer. This study was designed to evaluate the repeatability of intratumour uptake of the hypoxia tracer [18F]EF5 in paired PET/CT scans. METHODS: Ten patients with newly diagnosed head and neck cancer (HNC) received three static PET/CT scans before chemoradiotherapy: two with [18F]EF5 a median of 7 days apart and one with [18F]FDG. Metabolically active primary tumour volumes were defined in [18F]FDG images and transferred to co-registered [18F]EF5 images for repeatability analysis. A tumour-to-muscle uptake ratio (TMR) of 1.5 at 3 h from injection of [18F]EF5 was used as a threshold representing hypoxic tissue. RESULTS: In 10 paired [18F]EF5 PET/CT image sets, SUVmean, SUVmax, and TMR showed a good correlation with the intraclass correlation coefficients of 0.81, 0.85, and 0.87, respectively. The relative coefficients of repeatability for these parameters were 15%, 17%, and 10%, respectively. Fractional hypoxic volumes of the tumours in the repeated scans had a high correlation using the Spearman rank correlation test (r = 0.94). In a voxel-by-voxel TMR analysis between the repeated scans, the mean of Pearson correlation coefficients of individual patients was 0.65. The mean (± SD) difference of TMR in the pooled data set was 0.03 ± 0.20. CONCLUSION: Pretreatment [18F]EF5 PET/CT within one week shows high repeatability and is feasible for the guiding of hypoxia-targeted treatment interventions in HNC.