文献速递心脏核医学

使用抗重力跑台进行运动负荷试验联合锝-99m替曲膦单光子发射计算机断层心肌灌注显像的可行性与安全性:一项初步非随机对照研究

Feasibility and safety of exercise stress testing using an anti-gravity treadmill with Tc-99m tetrofosmin single-photon emission computed tomography (SPECT) myocardial perfusion imaging: A pilot non-randomized controlled study.
PubMed 文献 · J Nucl Cardiol · 2017-08-31

该初步非随机对照研究纳入49例自感运动能力差的患者,分别接受抗重力跑台运动负荷(n=29)或瑞加诺生药物负荷(n=20)行锝-99m替曲膦SPECT心肌灌注显像。抗重力跑台组17例(59%)达到目标心率而无需药物负荷剂,不良反应仅5例轻度肌肉酸痛;两组图像质量评分相当。作者认为抗重力跑台负荷试验可行,可能帮助部分患者安全达到目标心率。

要点

  • 抗重力跑台组29例中17例(59%)达到目标心率,无需使用药物负荷剂。
  • 抗重力跑台不良反应仅限5例轻度肌肉酸痛。
  • 抗重力跑台组与药物负荷组图像质量评分相当(4.30±0.87 vs 4.28±0.66)。

核心结论

  • 作者认为使用抗重力跑台进行负荷试验是可行的,可能帮助部分患者安全达到目标心率。

研究设计与样本

  • 初步非随机对照研究,共招募49例自感运动能力差的患者,抗重力跑台组29例,瑞加诺生对照组20例。

主要发现

  • 抗重力跑台组29例中17例(59%)达到目标心率,无需药物负荷剂。
  • 抗重力跑台不良反应仅限5例受试者轻度肌肉酸痛。
  • 3名盲法阅片者以5分制评估的图像质量:抗重力跑台组4.30±标准差0.87,药物负荷组4.28±标准差0.66,两组相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Exercise is the AHA/ACC guideline-recommended stress modality for myocardial perfusion imaging, but many patients are unable to exercise to target heart rate on a conventional treadmill. We examined the feasibility and safety of stress imaging using an anti-gravity treadmill in patients with perceived poor exercise capacity. METHODS AND RESULTS: 49 patients were recruited for stress testing by anti-gravity treadmill (n = 29) or to a regadenoson control group (n = 20). Seventeen anti-gravity test patients (59%) reached target heart rate obviating the need for a pharmacologic stress agent. Adverse effects of the anti-gravity treadmill were limited to minor muscle aches in 5 subjects. Stress myocardial perfusion image quality judged by 3 blinded readers on a 5-point scale was comparable for the anti-gravity treadmill (4.30 ± SD 0.87) vs pharmacologic stress (4.28 ± SD 0.66). CONCLUSION: Stress testing using an anti-gravity treadmill is feasible and may help some patients safely achieve target heart rate.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Daly P, Kayse R, Rudick S, et al. Feasibility and safety of exercise stress testing using an anti-gravity treadmill with Tc-99m tetrofosmin single-photon emission computed tomography (SPECT) myocardial perfusion imaging: A pilot non-randomized controlled study. J Nucl Cardiol. 2017. PMID: 28861743. doi:10.1007/s12350-017-1045-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。