文献速递肿瘤 PET/CT放射性药物与辐射防护

热成像可无创替代PET/CT测量人类棕色脂肪组织活性

Thermal Imaging Is a Noninvasive Alternative to PET/CT for Measurement of Brown Adipose Tissue Activity in Humans.
PubMed 文献 · J Nucl Med · 2017-09-14

该研究直接比较8名健康男性水套冷却后的红外热成像(IRT)与18F-FDG PET/CT数据,发现肩锁骨上区IRT温度变化与PET/CT葡萄糖摄取代谢率正相关(r²=0.721;P=0.008),最大摄取区与最高温度区空间重叠29.5%±5.1%,冷却60分钟较10分钟进一步升高肩锁骨上温度;作者认为IRT可作为测量棕色脂肪组织激活的合适方法。

要点

  • 肩锁骨上区IRT温度变化与PET/CT葡萄糖摄取代谢率正相关(r²=0.721;P=0.008)。
  • 最大葡萄糖摄取区与最高温度区空间重叠29.5%±5.1%。
  • 冷却60分钟较10分钟进一步升高肩锁骨上温度。

核心结论

  • IRT识别的肩锁骨上热点与PET/CT衍生的MR(gluc)MIP最大摄取区密切对应,相对TSCR升高幅度越大与葡萄糖摄取升高相关。
  • 作者认为IRT现可被视为测量棕色脂肪组织激活的合适方法,尤其适用于PET/CT不可行、不实际或不可重复的人群。

研究设计与样本

  • 直接比较8名健康男性水套冷却后的IRT与18F-FDG PET/CT数据。
  • 将热图像几何变换以叠加每位受试者PET/CT衍生的最大强度投影(MIP)图像,并比较肩锁骨上区温度与葡萄糖摄取最强烈区域。
  • 分析IRT肩锁骨上温度(TSCR)与PET/CT葡萄糖摄取代谢率(MR(gluc))之间的关系。

主要发现

  • MR(gluc)MIP葡萄糖摄取与相对于参考区域的TSCR变化呈正相关(r²=0.721;P=0.008)。
  • 最大MR(gluc)MIP区域与最大TSCR区域的空间重叠为29.5%±5.1%。
  • 与冷却10分钟相比,延长冷却60分钟与TSCR进一步升高相关。

关键数值与推荐

  • MR(gluc)MIP葡萄糖摄取与相对于参考区域的TSCR变化正相关(r²=0.721;P=0.008)。
  • 最大MR(gluc)MIP与最大TSCR的空间重叠为29.5%±5.1%。

临床怎么用

  • 作者认为IRT现可被视为测量棕色脂肪组织激活的合适方法,尤其适用于PET/CT不可行、不实际或不可重复的人群。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Obesity and its metabolic consequences are a major cause of morbidity and mortality. Brown adipose tissue (BAT) utilizes glucose and free fatty acids to produce heat, thereby increasing energy expenditure. Effective evaluation of human BAT stimulators is constrained by the current standard method of assessing BAT-PET/CT-as it requires exposure to high doses of ionizing radiation. Infrared thermography (IRT) is a potential noninvasive, safe alternative, although direct corroboration with PET/CT has not been established. Methods: IRT and 18F-FDG PET/CT data from 8 healthy men subjected to water-jacket cooling were directly compared. Thermal images were geometrically transformed to overlay PET/CT-derived maximum intensity projection (MIP) images from each subject, and the areas with the most intense temperature and glucose uptake within the supraclavicular regions were compared. Relationships between supraclavicular temperatures (TSCR) from IRT and the metabolic rate of glucose uptake (MR(gluc)) from PET/CT were determined. Results: Glucose uptake on MR(gluc)MIP was found to correlate positively with a change in TSCR relative to a reference region (r2 = 0.721; P = 0.008). Spatial overlap between areas of maximal MR(gluc)MIP and maximal TSCR was 29.5% ± 5.1%. Prolonged cooling, for 60 min, was associated with a further TSCR rise, compared with cooling for 10 min. Conclusion: The supraclavicular hotspot identified on IRT closely corresponded to the area of maximal uptake on PET/CT-derived MR(gluc)MIP images. Greater increases in relative TSCR were associated with raised glucose uptake. IRT should now be considered a suitable method for measuring BAT activation, especially in populations for whom PET/CT is not feasible, practical, or repeatable.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Law J, Morris DE, Izzi-Engbeaya C, et al. Thermal Imaging Is a Noninvasive Alternative to PET/CT for Measurement of Brown Adipose Tissue Activity in Humans. J Nucl Med. 2017. PMID: 28912148. doi:10.2967/jnumed.117.190546

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。