18F-FDG PET/CT在心血管植入式电子装置感染诊断中的作用:一项Meta分析
本Meta分析纳入14项研究、共492例患者,评估18F-FDG PET/CT诊断心血管植入式电子装置(CIED)感染的准确性。PET/CT诊断CIED感染的合并敏感度为83%(95%CI 78%-86%)、合并特异度为89%(95%CI 84%-94%);囊袋感染的敏感度为96%(95%CI 86%-99%)、特异度为97%(95%CI 86%-99%);导线感染或CIED感染性心内膜炎的诊断准确性较低,合并敏感度为76%(95%CI 65%-85%)、特异度为83%(95%CI 72%-90%)。作者认为PET/CT在CIED感染评估中具有较高的敏感度和特异度,值得在部分疑似CIED感染患者的管理中考虑。
要点
- PET/CT诊断CIED感染的合并敏感度为83%、合并特异度为89%。
- PET/CT诊断囊袋感染的敏感度为96%、特异度为97%。
- 导线感染或CIED感染性心内膜炎的敏感度为76%、特异度为83%。
核心结论
- PET/CT在CIED感染评估中具有较高的敏感度(83%)和特异度(89%),值得在部分疑似CIED感染患者的管理中考虑。
研究设计与样本
- 检索PubMed、Embase、Cochrane library、CINAHL、Web of Knowledge及www.clinicaltrials.gov自1990年1月至2017年4月的研究,纳入评估PET/CT诊断CIED感染准确性的研究进行Meta分析。
- 共纳入14项研究、涉及492例患者。
主要发现
- PET/CT诊断CIED感染的合并敏感度为83%(95%CI 78%-86%),合并特异度为89%(95%CI 84%-94%)。
- PET/CT诊断囊袋感染的敏感度为96%(95%CI 86%-99%),特异度为97%(95%CI 86%-99%)。
- PET/CT诊断导线感染或CIED感染性心内膜炎的合并敏感度为76%(95%CI 65%-85%),特异度为83%(95%CI 72%-90%)。
关键数值与推荐
- CIED感染:合并敏感度83%(95%CI 78%-86%),合并特异度89%(95%CI 84%-94%)。
- 囊袋感染:敏感度96%(95%CI 86%-99%),特异度97%(95%CI 86%-99%)。
- 导线感染或CIED感染性心内膜炎:合并敏感度76%(95%CI 65%-85%),特异度83%(95%CI 72%-90%)。
临床怎么用
- 作者认为PET/CT在CIED感染评估中具有较高的敏感度和特异度,值得在部分疑似CIED感染患者的管理中考虑。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: We performed a meta-analysis evaluating the use of fluorine-18-fluorodeoxyglucose (18F-FDG) positron-emission tomography (PET)/computed tomography (CT) in the diagnosis of cardiovascular implantable electronic device (CIED) infections. BACKGROUND: PET/CT may be helpful in the diagnosis of CIED infection, particularly in patients with the absence of localizing signs or definitive echocardiographic findings. METHODS: PubMed, Embase, Cochrane library, CINAHL, Web of Knowledge, and www.clinicaltrials.gov from January 1990 to April 2017 were searched for studies evaluating the accuracy of PET/CT in the diagnosis of CIED infections. RESULTS: Overall, 14 studies involving 492 patients were included in the meta-analysis. The pooled sensitivity of PET/CT for diagnosis of CIED infection was 83% (95% CI 78%-86%) and the pooled specificity was 89% (95% CI 84%-94%). PET/CT demonstrated a higher sensitivity of 96% (95% CI 86%-99%) and specificity of 97% (95% CI 86%-99%) for diagnosis of pocket infections. Diagnostic accuracy for lead infections or CIED-IE was lower with pooled sensitivity of 76% (95% CI 65%-85%) and specificity of 83% (95% CI 72%-90%). CONCLUSION: Use of PET/CT in the evaluation of CIED infection has both a high sensitivity (83%) and specificity (89%) and deserves consideration in the management of selected patients with suspected CIED infections.