18F-FLT与18F-FDG在新诊断结节病患者心脏及心外胸部受累检测中的对比评估
该回顾性研究纳入20例新诊断结节病患者,对比18F-FLT与18F-FDG PET/CT检测心脏及心外胸部受累。视觉分析中18F-FDG有4/20例因弥漫摄取判读不确定,而FLT无不确定病例;两者灵敏度、特异度、准确率分别为85%、100%、90%与92%、100%、95%。半定量分析显示FDG的SUVmax在心脏及心外病灶均显著高于FLT。
要点
- 18F-FDG有4/20例因弥漫摄取判读不确定,18F-FLT无不确定病例。
- 检测心脏结节病灵敏度FDG 85% vs FLT 92%,特异度均100%,准确率90% vs 95%。
- 心脏及心外病灶FDG的SUVmax均显著高于FLT(P<0.005及P<0.001)。
核心结论
- 这项初步研究提示,18F-FLT PET/CT检测新诊断结节病患者心脏及心外胸部受累的能力与18F-FDG PET/CT相当,尽管病灶对18F-FLT的摄取显著低于18F-FDG。
- 18F-FLT PET/CT操作可能更简便,因其无需长时间禁食或特殊饮食。
研究设计与样本
- 回顾性研究,纳入20例新诊断结节病患者,分别行18F-FLT与18F-FDG PET/CT,注射后1小时采集。
- 患者行18F-FDG PET/CT前禁食至少18小时,行18F-FLT PET/CT前无特殊饮食要求。
- 采用视觉分析和最大标准化摄取值(SUVmax)半定量分析评估摄取。
主要发现
- 2例为心脏结节病,7例为心外胸部结节病,11例同时有心脏和心外胸部结节病。
- 视觉分析诊断心脏结节病时,4/20例18F-FDG扫描因弥漫摄取被判读不确定,18F-FLT扫描无不确定病例。
- 18F-FDG PET/CT检测心脏结节病的灵敏度85%、特异度100%、准确率90%;18F-FLT PET/CT对应值为92%、100%、95%。
- 半定量分析心脏结节病,18F-FDG平均SUVmax显著高于18F-FLT平均SUVmax(P<0.005)。
- 18F-FDG与18F-FLT PET/CT均检出全部24个心外病灶;半定量分析心外结节病,18F-FDG平均SUVmax显著高于18F-FLT平均SUVmax(P<0.001)。
局限性
- 原文结论称本研究为初步研究(preliminary study)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: 18F-FDG PET has been used in sarcoidosis for diagnosis and determination of the extent of the disease. However, assessing inflammatory lesions in cardiac sarcoidosis using 18F-FDG can be challenging because it accumulates physiologically in normal myocardium. Another radiotracer, 3'-deoxy-3'-18F-fluorothymidine (18F-FLT), has been investigated as a promising PET tracer for evaluating tumor proliferative activity. In contrast to 18F-FDG, 18F-FLT uptake in the normal myocardium is low. The purpose of this retrospective study was to compare the uptake of 18F-FLT and 18F-FDG in the evaluation of cardiac and extra-cardiac thoracic involvement in patients with newly diagnosed sarcoidosis. Data for 20 patients with newly diagnosed sarcoidosis were examined. 18F-FLT and 18F-FDG PET/CT studies had been performed at 1 h after each radiotracer injection. The patients had fasted for at least 18 h before 18F-FDG PET/CT but were given no special dietary instructions regarding the period before 18F-FLT PET/CT. Uptake of 18F-FLT and 18F-FDG was examined visually and semiquantitatively using maximal standardized uptake value (SUVmax). RESULTS: Two patients had cardiac sarcoidosis, 7 had extra-cardiac thoracic sarcoidosis, and 11 had both cardiac and extra-cardiac thoracic sarcoidosis. On visual analysis for diagnosis of cardiac sarcoidosis, 4/20 18F-FDG scans were rated as inconclusive because the 18F-FDG pattern was diffuse, whereas no FLT scans were rated as inconclusive. The sensitivity of 18F-FDG PET/CT for detection of cardiac sarcoidosis was 85%; specificity, 100%; and accuracy, 90%. The corresponding values for 18F-FLT PET/CT were 92, 100, and 95%, respectively. Using semiquantitative analysis of cardiac sarcoidosis, the mean 18F-FDG SUVmax was significantly higher than the mean 18F-FLT SUVmax (P < 0.005). Both 18F-FDG and 18F-FLT PET/CT studies detected all 24 extra-cardiac lesions. Using semiquantitative analysis of extra-cardiac sarcoidosis, the mean 18F-FDG SUVmax was significantly higher than the mean 18F-FLT SUVmax (P < 0.001). CONCLUSIONS: The results of this preliminary study suggest that 18F-FLT PET/CT can detect cardiac and extra-cardiac thoracic involvement in patients with newly diagnosed sarcoidosis as well as 18F-FDG PET/CT, although uptake of 18F-FLT in lesions was significantly lower than that of 18F-FDG. However, 18F-FLT PET/CT may be easier to perform since it requires neither prolonged fasting nor a special diet prior to imaging.
引用
- Norikane T, Yamamoto Y, Maeda Y, et al. Comparative evaluation of 18F-FLT and 18F-FDG for detecting cardiac and extra-cardiac thoracic involvement in patients with newly diagnosed sarcoidosis. EJNMMI Res. 2017. PMID: 28853043. doi:10.1186/s13550-017-0321-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。