文献速递心脏核医学肿瘤 PET/CT

18F-FDG PET/CT对急性B型主动脉壁内血肿患者的预测价值

Predictive value of 18F-FDG PET/CT in patients with acute type B aortic intramural hematoma.
PubMed 文献 · J Nucl Cardiol · 2017-08-02

本研究纳入34例急性Stanford B型主动脉壁内血肿患者,于症状发作14天内行18F-FDG PET/CT。有无主动脉不良事件(AAE)患者的SUVmax差异有统计学意义(4.3±0.6 vs 3.7±1.0,P=0.020),TBR差异无统计学意义。在25例(74%)有初始溃疡样突起(ULP)的患者中,发生AAE者SUVmax和TBR均显著更高,TBR>1.5预测AAE的敏感度73%、特异度80%。

要点

  • 急性B型IMH患者中,有无AAE者的SUVmax差异有统计学意义(4.3±0.6 vs 3.7±1.0,P=0.020)。
  • 有ULP的25例(74%)患者中,发生AAE者SUVmax和TBR均显著更高(P=0.001;P=0.01)。
  • TBR>1.5预测AAE的敏感度73%、特异度80%,作者认为ULP伴高18F-FDG摄取者更易发生AAE,可能需要更密切的连续影像监测。

核心结论

  • 有溃疡样突起(ULP)且18F-FDG摄取高的患者更可能发生主动脉不良事件(AAE),可能需要更密切的连续影像监测。

研究设计与样本

  • 本研究纳入34例急性Stanford B型主动脉壁内血肿(IMH)患者,于症状发作14天内行18F-FDG PET/CT。

主要发现

  • 有无AAE患者的SUVmax差异有统计学意义(4.3±0.6 vs 3.7±1.0,P=0.020)。
  • 有无AAE患者的靶/血比值(TBR,SUVmax除以上腔静脉SUV)差异无统计学意义(1.6±0.2 vs 1.5±0.5,P=0.064)。
  • 25例(74%)有初始ULP的患者中,发生AAE者SUVmax和TBR均显著更高(4.3±0.6 vs 3.3±0.5,P=0.001;1.6±0.2 vs 1.4±0.2,P=0.01)。
  • 由受试者工作特征曲线确定的TBR>1.5预测AAE的敏感度为73%、特异度为80%。

关键数值与推荐

  • 在有初始ULP的患者中,TBR>1.5预测AAE的敏感度为73%、特异度为80%。

临床怎么用

  • 作者认为,有ULP且18F-FDG摄取高的患者更可能发生AAE,可能需要更密切的连续影像监测。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The clinical course and predictors of adverse aortic events (AAE) in patients with acute Stanford type B intramural hematoma (IMH) remain controversial. This study aimed to investigate whether 18F-FDG PET/CT can predict risk in patients with acute type B IMH. METHODS AND RESULTS: This study included 34 patients with acute type B IMH who underwent PET/CT within 14 days from the onset of symptoms. The maximal standardized uptake values (SUVmax) of 18F-FDG uptake was significantly different between patients with or without AAE (4.3 ± 0.6 vs 3.7 ± 1.0, P = 0.020), but not the target to blood ratio (TBR, SUVmax divided by SUV in the superior vena cava) (1.6 ± 0.2 vs 1.5 ± 0.5, P = 0.064). In patients with initial ulcer-like projection (ULP), a blood-filled pouch protruding into the IMH, which was seen in 25 patients(74%), both the SUVmax and TBR were significantly higher in patients who developed AAE, (4.3 ± 0.6 vs 3.3 ± 0.5, P = 0.001; 1.6 ± 0.2 vs 1.4 ± 0.2, P = 0.01); the TBR >1.5, which is determined from receiver-operating-characteristic curve, had a sensitivity of 73% and a specificity of 80% in predicting AAE. CONCLUSION: Patients with ULP and high 18F-FDG uptake were more likely to develop AAE and may require closer surveillance with serial imaging.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Yang F, Luo J, Hou Q, et al. Predictive value of 18F-FDG PET/CT in patients with acute type B aortic intramural hematoma. J Nucl Cardiol. 2017. PMID: 28770462. doi:10.1007/s12350-017-1014-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。