基因分型健康人脑与血液中转运蛋白18 kDa配体信号的变异性:123I-CLINDE SPECT显像的重测研究
本研究用123I-CLINDE SPECT在16名健康对照者中重复扫描(间隔35±15天),评估脑内TSPO结合的重测变异性。结果显示SUV与分布容积(VT)的绝对百分比差异相似,VT的组内相关系数(ICC)高于SUV,但按高亲和力结合者(HAB)与混合亲和力结合者(MAB)分开计算时ICC较低;作者结论认为123I-CLINDE的重测重现性不劣于常用PET TSPO示踪剂,但SUV不足以替代两组织房室模型VT。
要点
- 16名健康者(9女,8名MAB与8名HAB)接受两次123I-CLINDE SPECT,间隔35±15天。
- 脑SUV与两组织房室模型VT的绝对百分比差异相似,VT的ICC高于SUV。
- 按HAB与MAB分开计算时ICC较低;血样立即离心者重测重现性更高。
核心结论
- 123I-CLINDE的重测重现性与常用PET TSPO示踪剂相当或更优。
- 由于123I-CLINDE与血细胞及外周组织结合,SUV不足以作为两组织房室模型VT的替代指标。
- 群体校正方法有潜力降低TSPO示踪剂血液分析的复杂性。
研究设计与样本
- 在16名健康对照者(9名女性,8名混合亲和力结合者MAB与8名高亲和力结合者HAB)中于90分钟内采集SPECT,间隔35±15天重复两次。
- 动脉输入函数在8名受试者中基于个体血液测量,在另8名受试者中采用群体方法结合个体全血时间-放射性曲线。
- 提取7个脑感兴趣区,用SUV和两组织房室模型计算分布容积VT进行定量。
- 重测变异性用百分比差异(PD)、绝对PD、组内相关系数(ICC)和变异系数衡量。
主要发现
- 脑SUV与VT的绝对PD相似。
- VT的ICC值高于脑SUV的ICC值,两者均为中至高度;但按HAB与MAB分开计算时ICC较低。
- 血样立即离心的受试者重测重现性更高,群体方法能有效恢复延迟离心的数据。
- 49岁男性HAB的VT为7.5±1.4 mL/cm3,性别年龄匹配的MAB为4.6±1.4 mL/cm3。
- 49岁男性HAB与MAB的SUV分别为1.03±0.14 g/mL和0.88±0.15 g/mL。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
123I-CLINDE is a radiotracer developed for SPECT and targets the 18-kDa translocator protein (TSPO). TSPO is upregulated in glial cells and used as a measure of neuroinflammation in a variety of central nervous system diseases. The aim of this study was to examine the test-retest variability of 123I-CLINDE binding in healthy subjects. Methods: SPECT scans were acquired over 90 min in 16 healthy controls (9 women, 8 mixed-affinity binders [MABs] and 8 high-affinity binders [HABs] twice with an interval of 35 ± 15 d). Arterial input functions were based on individual blood measurements in 8 subjects and a population-based approach in combination with individual whole-blood time-activity curves in the other 8 subjects. Seven brain volumes of interest were extracted and quantified by SUVs and by 2-tissue-compartment modeling for calculation of distribution volumes (VT). Test-retest variability was measured by percentage difference (PD), the absolute PD, intraclass correlation coefficient (ICC), and coefficient of variation. Results: The absolute PD of brain SUV and the VT had similar values. The ICC values were higher for VTs than for brain SUVs, which were both moderate to high; however, lower ICC values were observed when calculated separately for HABs and MABs. Test-retest reproducibility was higher in subjects with immediate centrifugation of blood samples. The population-based method efficiently recovered data with delayed centrifugation. The VT of a 49-y-old male HAB was 7.5 ± 1.4 mL/cm3 compared with 4.6 ± 1.4 mL/cm3 of a sex- and age-matched MAB. The SUVs of a 49-y-old male HAB and MAB were 1.03 ± 0.14 and 0.88 ± 0.15 g/mL, respectively. Conclusion: The test-retest reproducibility of 123I-CLINDE is comparable or better than that reported for commonly used PET TSPO tracers. Because of the binding of 123I-CLINDE to blood cells and peripheral tissues, SUV is not a sufficient surrogate of VT from 2-tissue-compartment modeling. The population-adjusted method has the potential to reduce the complexity of blood analyses of TSPO tracers.
引用
- Feng L, Jensen P, Thomsen G, et al. The Variability of Translocator Protein Signal in Brain and Blood of Genotyped Healthy Humans Using In Vivo 123I-CLINDE SPECT Imaging: A Test-Retest Study. J Nucl Med. 2016. PMID: 28572290. doi:10.2967/jnumed.116.183202
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。