文献速递核素与放射性配体治疗肿瘤 PET/CT

177Lu-DOTATATE/DOTATOC内照射治疗后第4天单次测量生成剂量图

Dose Mapping After Endoradiotherapy with 177Lu-DOTATATE/DOTATOC by a Single Measurement After 4 Days.
PubMed 文献 · J Nucl Med · 2017-06-06

回顾性分析29例神经内分泌肿瘤或脑膜瘤患者接受177Lu-DOTATATE/DOTATOC后的平面影像动力学,评估以单次测量时间点tl的活度读数乘以2/ln(2)近似时间积分的准确性。结果显示tl为96小时或更长时各组织Pearson r均超过0.95,96小时处肾脏、肝脏、脾脏和NET病灶的偏差中位数分别为+5%、+6%、+8%和+6%;72或120小时测量准确性降低,24、48和144小时测量对部分患者偏差大,尤其肾脏吸收剂量被不可接受地低估。结论认为给药后4天SPECT/CT单次定量测量腹部活度浓度可提供三维剂量图并估算治疗周期实际吸收剂量。

要点

  • 给药后96小时单次测量近似时间积分,各组织Pearson r均超过0.95。
  • 96小时处偏差中位数:肾脏+5%、肝脏+6%、脾脏+8%、NET病灶+6%。
  • 72或120小时测量准确性降低,24、48和144小时对部分患者偏差大。

核心结论

  • 给药后4天SPECT/CT单次定量测量腹部活度浓度可提供三维剂量图,并可用于估算治疗周期实际吸收剂量,额外资源与工作量较小。

研究设计与样本

  • 回顾性分析29例神经内分泌肿瘤(n=21)或脑膜瘤(n=8)患者接受177Lu-DOTATATE(n=22)或177Lu-DOTATOC(n=7)后的平面影像活度动力学。
  • 对54个肾脏、25个肝脏、27个脾脏和30个NET病灶的实测数据拟合单指数或双指数函数。
  • 评估以单次测量时间点tl的预期读数乘以因子2/ln(2)所得近似值代表时间积分的准确性,tl取24、48、72、96、120和144小时。

主要发现

  • 时间积分与近似值的相关性随时间tl增加而改善,tl为96小时或更长时所有组织Pearson r均超过0.95。
  • tl为96小时时最大误差最低,肾脏偏差中位数+5%(范围-9%至+17%),肝脏+6%(范围-7%至+12%),脾脏+8%(范围+2%至+20%),NET病灶+6%(范围-11%至+16%)。
  • 72或120小时测量准确性降低;24、48和144小时测量对部分患者导致大偏差,尤其肾脏吸收剂量被不可接受地低估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Dosimetry of organs and tumors helps to assess risks and benefit of treatment with 177Lu-DOTATATE/DOTATOC. However, it is often not performed in clinical routine because of additional efforts, the complexity of data collection and analysis, and the additional burden for the patients. Aiming at a simplification of dosimetry, we analyzed the accuracy of a theoretically substantiated approximation, which allows the calculation of absorbed doses from a single measurement of the abdominal activity distribution. Methods: Activity kinetics were retrospectively assessed from planar images in 29 patients with neuroendocrine tumors (NETs; n = 21) or meningioma (n = 8) after the administration of 177Lu-DOTATATE (n = 22) or 177Lu-DOTATOC (n = 7). Mono- or biexponential functions were fitted to measured data in 54 kidneys, 25 livers, 27 spleens, and 30 NET lesions. It was evaluated for each fit function how well the integral over time was represented by an approximation calculated as the product of the time tl of a single measurement, the expected reading at time tl, and the factor 2/ln(2). Tissue-specific deviations of the approximation from the time integral were calculated for time points tl of 24, 48, 72, 96, 120, and 144 h. Results: The correlation between time integral and approximation improved with increasing time tl Pearson r exceeded 0.95 for a tl of 96 h or more in all tissues. The lowest maximum errors were observed at a tl of 96 h, with deviations of the approximation from the time integral of median +5% (range, -9% to +17%) for kidneys, +6% (range, -7% to +12%) for livers, +8% (range, +2% to +20%) for spleens, and +6% (range, -11% to +16%) for NET lesions. Accuracy was reduced for measurements after 72 or 120 h. For measurements after 24, 48, and 144 h, the approximation led to large deviations for some of the patients, in particular unacceptable underestimates of the absorbed dose to the kidneys. Conclusion: A single quantitative measurement of the abdominal activity concentration by SPECT/CT 4 d after the administration of 177Lu-DOTATATE/DOTATOC provides a 3-dimensional dose map and can be used to estimate the doses actually absorbed in the treatment cycle with minor additional resources and effort.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Hänscheid H, Lapa C, Buck AK, et al. Dose Mapping After Endoradiotherapy with 177Lu-DOTATATE/DOTATOC by a Single Measurement After 4 Days. J Nucl Med. 2017. PMID: 28588150. doi:10.2967/jnumed.117.193706

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。