文献速递神经核医学

结合定量信息增强淀粉样蛋白PET判读可提高早期淀粉样斑块检测的一致性

Augmenting Amyloid PET Interpretations With Quantitative Information Improves Consistency of Early Amyloid Detection.
PubMed 文献 · Clin Nucl Med · 2017-01-01

研究由3名经验丰富的判读者对55例氟比他班(F-florbetapir)PET扫描进行判读,比较视觉判读、定量判读及两者结合的VisQ判读。定量信息加入后,判读者间一致性从视觉判读的kappa 0.73–0.82提高至VisQ判读的0.88–0.96,16次判读(9.7%)发生改变。结论认为纳入定量信息可提高早期脑淀粉样β斑块检测的判读一致性。

要点

  • 55例氟比他班PET扫描由3名判读者分别进行视觉、定量及VisQ判读。
  • 视觉判读中斑块升高比例为25.5%–29.1%,定量判读中升高比例为45.5%。
  • 加入定量信息后判读者间一致性kappa由0.73–0.82升至0.88–0.96。

核心结论

  • 纳入定量信息可提高PET扫描判读用于早期检测脑淀粉样β斑块积累的一致性。

研究设计与样本

  • 由3名经验丰富的判读者对55例氟比他班(F-florbetapir)PET扫描进行判读。
  • 先进行视觉判读,再使用标准化定量分析软件(MIMneuro)生成全脑及感兴趣区SUV比值进行定量判读,最后结合两者形成VisQ判读。
  • 定量判读定义为6个感兴趣区中至少2个SUV比值大于1.1。

主要发现

  • 在165次总视觉判读中,斑块升高比例为25.5%至29.1%。
  • 判读者间一致性为强(kappa=0.73–0.82),与已报告值一致。
  • 定量判读中参与者斑块升高比例为45.5%。
  • 最终VisQ判读与初始视觉判读相比有16次判读(9.7%)发生改变,多数由视觉判读的「未升高」变为「升高」。
  • 发生改变的判读其斑块定量值低于初始判读为「升高」且未改变的判读。

关键数值与推荐

  • 定量判读标准:6个感兴趣区中至少2个SUV比值大于1.1时判为升高。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Establishing reliable methods for interpreting elevated cerebral amyloid-β plaque on PET scans is increasingly important for radiologists, as availability of PET imaging in clinical practice increases. We examined a 3-step method to detect plaque in cognitively normal older adults, focusing on the additive value of quantitative information during the PET scan interpretation process. METHODS: Fifty-five F-florbetapir PET scans were evaluated by 3 experienced raters. Scans were first visually interpreted as having "elevated" or "nonelevated" plaque burden ("Visual Read"). Images were then processed using a standardized quantitative analysis software (MIMneuro) to generate whole brain and region of interest SUV ratios. This "Quantitative Read" was considered elevated if at least 2 of 6 regions of interest had an SUV ratio of more than 1.1. The final interpretation combined both visual and quantitative data together ("VisQ Read"). Cohen kappa values were assessed as a measure of interpretation agreement. RESULTS: Plaque was elevated in 25.5% to 29.1% of the 165 total Visual Reads. Interrater agreement was strong (kappa = 0.73-0.82) and consistent with reported values. Quantitative Reads were elevated in 45.5% of participants. Final VisQ Reads changed from initial Visual Reads in 16 interpretations (9.7%), with most changing from "nonelevated" Visual Reads to "elevated." These changed interpretations demonstrated lower plaque quantification than those initially read as "elevated" that remained unchanged. Interrater variability improved for VisQ Reads with the addition of quantitative information (kappa = 0.88-0.96). CONCLUSIONS: Inclusion of quantitative information increases consistency of PET scan interpretations for early detection of cerebral amyloid-β plaque accumulation.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Harn NR, Hunt SL, Hill J, et al. Augmenting Amyloid PET Interpretations With Quantitative Information Improves Consistency of Early Amyloid Detection. Clin Nucl Med. 2017. PMID: 28574875. doi:10.1097/RLU.0000000000001693

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。