文献速递心脏核医学

三维采集的PET/CT扫描在诊断冠状动脉疾病时可行地定量心肌血流量

PET/CT scanning with 3D acquisition is feasible for quantifying myocardial blood flow when diagnosing coronary artery disease.
PubMed 文献 · EJNMMI Res · 2017-06-05

研究纳入24例已知或疑似冠状动脉疾病(CAD)患者与8例年龄匹配健康志愿者,行静息及药物负荷15O-水PET/CT三维采集灌注显像,定量整体及三个冠状动脉供血区心肌血流量(MBF)与冠脉血流储备(CFR)。患者整体CFR显著低于志愿者(2.75 ± 0.81 vs. 4.54 ± 0.66,p = 0.0002),狭窄区域CFR较非狭窄区域有降低趋势(2.43 ± 0.81 vs. 2.95 ± 0.92,p = 0.052)。作者结论认为三维采集15O-水PET/CT可可靠用于CAD患者功能性MBF与CFR定量。

要点

  • 15O-水剂量500 MBq、三维采集的PET/CT显像质量良好。
  • 整体及区域MBF分析观察者间相关性均强(r > 0.90,p < 0.001)。
  • 患者整体CFR显著低于志愿者(2.75 ± 0.81 vs. 4.54 ± 0.66,p = 0.0002)。

核心结论

  • 三维数据采集的15O-水PET/CT可可靠用于CAD患者功能性MBF与CFR的定量。

研究设计与样本

  • 研究纳入24例已知或疑似CAD患者与8例年龄匹配健康志愿者,行静息及药物负荷15O-水PET/CT灌注显像。

主要发现

  • 健康志愿者静息MBF三区域间无显著差异(LAD 0.82 ± 0.15 ml/min/g;LCX 0.83 ± 0.17 ml/min/g;RCA 0.71 ± 0.20 ml/min/g;p = 0.74)。
  • 健康志愿者负荷MBF三区域间无显著差异(LAD 3.77 ± 1.00 ml/min/g;LCX 3.56 ± 1.01 ml/min/g;RCA 3.27 ± 1.04 ml/min/g;p = 0.62)。
  • 健康志愿者CFR三区域间无显著差异(LAD 4.64 ± 0.90;LCX 4.30 ± 0.64;RCA 4.64 ± 0.96;p = 0.66)。
  • 患者整体CFR显著低于志愿者(2.75 ± 0.81 vs. 4.54 ± 0.66,p = 0.0002)。
  • 患者狭窄区域CFR较非狭窄区域有降低趋势(2.43 ± 0.81 vs. 2.95 ± 0.92,p = 0.052),未达统计学显著。

关键数值与推荐

  • 采用15O-水剂量500 MBq与三维数据采集。
  • 整体及区域MBF分析的观察者间组内相关系数r > 0.90(p < 0.001)。
  • CFR按三磷酸腺苷诱导负荷时MBF与静息MBF的比值计算。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The quantification of myocardial blood flow (MBF) and coronary flow reserve (CFR) are useful approaches for evaluating the functional severity of coronary artery disease (CAD). 15O-water positron emission tomography (PET) is considered the gold standard method for MBF quantification. However, MBF measurements in 15O-water PET with three-dimensional (3D) data acquisition, attenuation correction using computed tomography (CT), and time of flight have not been investigated in detail or validated. We conducted this study to evaluate the diagnostic potential of MBF measurements using PET/CT for a comparison of a control group and patients suspected of having CAD. RESULTS: Twenty-four patients with known or suspected CAD and eight age-matched healthy volunteers underwent rest and pharmacological stress perfusion studies with 15O-water PET/CT. The whole and three regional (left anterior descending (LAD), left circumflex (LCX), and right coronary artery (RCA) territory) MBF values were estimated. The CFR was computed as the ratio of the MBF during adenosine triphosphate-induced stress to the MBF at rest. The inter-observer variability was assessed by two independent observers. PET/CT using a 15O-water dose of 500 MBq and 3D data acquisition showed good image quality. A strong inter-observer correlation was detected in both the whole MBF analysis and the regional analysis with high intra-class correlation coefficients (r > 0.90, p < 0.001). Regional MBF at rest (LAD, 0.82 ± 0.15 ml/min/g; LCX, 0.83 ± 0.17 ml/min/g; RCA, 0.71 ± 0.20 ml/min/g; p = 0.74), MBF at stress (LAD, 3.77 ± 1.00 ml/min/g; LCX, 3.56 ± 1.01 ml/min/g; RCA, 3.27 ± 1.04 ml/min/g; p = 0.62), and CFR (LAD, 4.64 ± 0.90; LCX, 4.30 ± 0.64; RCA, 4.64 ± 0.96; p = 0.66) of the healthy volunteers showed no significant difference among the three regions. The global CFR of the patients was significantly lower than that of the volunteers (2.75 ± 0.81 vs. 4.54 ± 0.66, p = 0.0002). The regional analysis of the patients demonstrated that the CFR tended to be lower in the stenotic region compared to the non-stenotic region (2.43 ± 0.81 vs. 2.95 ± 0.92, p = 0.052). CONCLUSIONS: 15O-water PET/CT with 3D data acquisition can be reliably used for the quantification of functional MBF and CFR in CAD patients.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Manabe O, Naya M, Aikawa T, et al. PET/CT scanning with 3D acquisition is feasible for quantifying myocardial blood flow when diagnosing coronary artery disease. EJNMMI Res. 2017. PMID: 28585219. doi:10.1186/s13550-017-0296-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。