低剂量双同位素方案在CZT-SPECT心肌灌注显像中的计划及与常规单同位素方案的头对头比较评估
本研究评估一种低剂量双同位素方案:负荷Tc-99m司他比膦甲氧基异腈(Sestamibi)SPECT异常后行静息Tl-201 SPECT,并与单同位素方案进行头对头比较。102例患者在CZT相机上接受低剂量负荷Sestamibi SPECT后,于负荷与静息Sestamibi SPECT之间加做Tl-201静息SPECT。双同位素方案平均有效剂量为8.3 mSv,若37%患者无需静息SPECT则可降至5.7 mSv。经本底校正后,双同位素与单同位素方案识别缺血节段的静息-负荷心肌摄取差异等效(曲线下面积分别为0.83±0.03和0.81±0.03)。
要点
- 低剂量双同位素方案(负荷Sestamibi后静息Tl-201)平均有效剂量8.3 mSv。
- 若37%患者无需静息SPECT,有效剂量可降至5.7 mSv。
- 本底校正后,双同位素与单同位素方案识别缺血节段的曲线下面积分别为0.83±0.03和0.81±0.03。
核心结论
- 这种原创双同位素方案提供了可接受的辐射剂量和一致的结果,与常规单同位素方案相当。
研究设计与样本
- 102例患者因临床需要接受低剂量负荷Sestamibi SPECT(123±20 MBq)并需静息Sestamibi SPECT,在CZT相机上于负荷与静息Sestamibi SPECT之间加做Tl-201静息SPECT(52±5 MBq)。
- 对Tl-201图像进行溢出和散射校正,并分析其与负荷Sestamibi SPECT的摄取差异。
主要发现
- 双同位素方案平均有效剂量为8.3 mSv;若预期37%患者无需静息SPECT,则可降至5.7 mSv。
- 对Tl-201图像进一步本底校正后,双同位素与单同位素方案识别缺血节段的静息-负荷心肌摄取差异等效,曲线下面积分别为0.83±0.03和0.81±0.03。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE OF THE REPORT: This study aimed at assessing an original low-dose dual-isotope procedure in which the abnormal stress Tc-99m Sestamibi SPECT is followed by rest Tl-201 SPECT, along with a head-to-head comparison with a single-isotope procedure. METHODS AND RESULTS: One hundred two patients, referred for a low-dose stress-SPECT with Sestamibi (123 ± 20 MBq) on a CZT camera and for whom a rest Sestamibi SPECT was warranted, had an additional Tl-201 rest-SPECT (52 ± 5 MBq) between stress and rest Sestamibi SPECT recordings. Tl-201 images were processed for spill-over and scatter corrections, and uptake differences with stress Sestamibi SPECT were analyzed: (1) for rest acquisitions from Tl-201 (dual-isotope procedure) and from Sestamibi (single-isotope procedure) and (2) in segments for which a diagnosis of ischemia, infarct, or normal perfusion was achieved. Mean effective dose was 8.3 mSv for dual-isotope but would decrease to 5.7 mSv for an expected rate of 37% of patients for whom rest-SPECT is not warranted. After a further background correction of Tl-201 images, the rest-stress difference in myocardial uptake was equivalent between dual- and single-procedures for identifying ischemic segments (respective areas-under-curves: 0.83 ± 0.03 and 0.81 ± 0.03). CONCLUSION: This original dual-isotope procedure provides acceptable radiation doses and consistent results, as compared with conventional single-isotope.
引用
- Imbert L, Roch V, Merlin C, et al. Low-dose dual-isotope procedure planed for myocardial perfusion CZT-SPECT and assessed through a head-to-head comparison with a conventional single-isotope protocol. J Nucl Cardiol. 2017. PMID: 28512723. doi:10.1007/s12350-017-0914-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。