文献速递心脏核医学

优化82铷PET心肌血流量化中的时间采样

Optimization of temporal sampling for 82rubidium PET myocardial blood flow quantification.
PubMed 文献 · J Nucl Cardiol · 2017-05-15

研究纳入24名正常志愿者和32例患者,行负荷/静息动态82Rb PET显像,评估不同帧时长对心肌血流量(MBF)和血流储备(MFR)估计的影响。结果显示血池TAC的FWHM与最长采样间隔TS线性相关(R=0.93);血相帧时长从5秒增至15秒导致MBF和MFR偏差6-12%、变异性增加14-24%,而<5秒帧时长偏差小于5%;组织相帧时长从30秒增至120秒偏差<5%。结论认为血相5秒、组织相120秒的两相帧设置可最优采样血池TAC。

要点

  • 血相帧时长从5秒增至15秒使MBF和MFR偏差达6-12%、变异性增加14-24%。
  • 血相帧时长<5秒时MBF和MFR偏差均小于5%。
  • 组织相帧时长从30秒增至120秒偏差小于5%。

核心结论

  • 对现代3D PET系统,动态82Rb PET图像采用血相5秒、组织相120秒的两相帧设置可最优采样血池TAC。

研究设计与样本

  • 研究纳入24名正常志愿者和32例患者,行负荷/静息动态82Rb PET显像,采用精细时间采样估计左心室血池TAC的半高全宽(FWHM),并用傅里叶分析确定最长采样间隔TS与FWHM的关系。
  • 动态数据集在血相前2分钟采用2至20秒帧时长重建,组织相采用30至120秒帧时长重建,通过感兴趣区(ROI)采样左心室血池和组织TAC并拟合房室模型量化MBF和MFR。
  • 利用临床数据和模拟评估时间采样对MBF和MFR的影响。

主要发现

  • 最长采样间隔TS随输入函数FWHM线性增加(R=0.93)。
  • 血相帧时长从5秒增至15秒导致MBF和MFR偏差6-12%、变异性增加14-24%。
  • 血相帧时长<5秒时MBF和MFR偏差均小于5%。
  • 组织相帧时长从30秒增至120秒导致偏差小于5%。

关键数值与推荐

  • 血相帧时长<5秒时MBF和MFR偏差均小于5%。
  • 血相帧时长从5秒增至15秒导致MBF和MFR偏差6-12%、变异性增加14-24%。
  • 组织相帧时长从30秒增至120秒导致偏差小于5%。
  • 最长采样间隔TS与输入函数FWHM的相关系数R=0.93。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Suboptimal temporal sampling of left ventricular (LV) blood pool and tissue time-activity curves (TACs) may introduce bias and increased variability in estimates of myocardial blood flow (MBF) and flow reserve (MFR) from dynamic PET myocardial perfusion images. We aimed to optimize temporal sampling for estimation of MBF and MFR. METHODS: Twenty-four normal volunteers and 32 patients underwent dynamic stress/rest rubidium-82 chloride (82Rb) PET imaging. Fine temporal sampling was used to estimate the full width at half maximum (FWHM) of the LV blood pool TAC. Fourier analysis was used to determine the longest sampling interval, T S, as a function of FWHM, which preserved the information content of the blood phase. Dynamic datasets were reconstructed with frame durations varying from 2 to 20 seconds over the first 2 minutes for the blood phase and 30 to 120 seconds for the tissue phase. The LV blood pool and tissue TACs were sampled using regions of interest (ROI) and fit to a compartment model for quantification of MBF and MFR. The effects of temporal sampling on MBF and MFR were evaluated using clinical data and simulations. RESULTS: T S increased linearly with input function FWHM (R = 0.93). Increasing the blood phase frame duration from 5 to 15 seconds resulted in MBF and MFR biases of 6-12% and increased variability of 14-24%. Frame durations <5 seconds had biases of less than 5% for both MBF and MFR values. Increasing the tissue phase frame durations from 30 to 120 seconds resulted in <5% biases. CONCLUSIONS: A two-phase framing of dynamic 82Rb PET images with frame durations of 5 seconds (blood phase) and 120 seconds (tissue phase) optimally samples the blood pool TAC for modern 3D PET systems.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Lee BC, Moody JB, Weinberg RL, et al. Optimization of temporal sampling for 82rubidium PET myocardial blood flow quantification. J Nucl Cardiol. 2017. PMID: 28508271. doi:10.1007/s12350-017-0899-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。