文献速递肿瘤 PET/CT放射性药物与辐射防护

手臂截断对68Ga-PSMA-11(HBED-CC)PET/MRI中晕状伪影表现的影响

Effects of arm truncation on the appearance of the halo artifact in 68Ga-PSMA-11 (HBED-CC) PET/MRI.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2017-05-15

该研究纳入27例连续患者,先行68Ga-PSMA-11 PET/CT(注射后1小时),再行PET/MRI(注射后3小时);PET/MRI先以双臂上举过头采集腹部至盆腔,随后以双臂下垂于躯干旁采集盆腔至腹部。结果显示双臂上举时晕状伪影显著减轻,位于晕状伪影内的病灶SUVmean(p=0.0007)和SUVmax(p=0.0024)显著升高;晕状伪影的表现和强度不依赖于膀胱总活度和活度浓度。

要点

  • 双臂下垂与PET/MRI中晕状伪影的出现显著相关。
  • 双臂上举过头可显著减轻晕状伪影,从而检测到更多肿瘤病灶。
  • 晕状伪影的表现和强度不依赖于膀胱总活度和活度浓度。

核心结论

  • 双臂下垂被证明与PET/MRI中晕状伪影的出现显著相关。
  • 双臂上举过头可显著减轻晕状伪影,从而检测到更多肿瘤病灶。

研究设计与样本

  • 该评估纳入27例连续患者,先行68Ga-PSMA-11 PET/CT(注射后1小时),再行PET/MRI(注射后3小时)。
  • PET/MRI先以双臂上举过头采集腹部至盆腔,随后立即以双臂下垂于躯干旁采集盆腔至腹部。
  • 所有检查先单独分析,再就肿瘤检测、肿瘤摄取(SUV)以及晕状伪影的存在和强度进行比较。
  • 采用Wilcoxon符号秩检验确定统计学差异,并进行Bonferroni校正。

主要发现

  • 双臂上举时晕状伪影显著减轻。
  • 位于晕状伪影内的病灶(n=16)在双臂上举时SUVmean显著升高(p=0.0007)。
  • 位于晕状伪影内的病灶(n=16)在双臂上举时SUVmax显著升高(p=0.0024)。
  • 晕状伪影的表现和强度不依赖于膀胱总活度和活度浓度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: PSMA ligand imaging with hybrid PET/MRI scanners could be an integral part of the clinical routine in the future. However, the first study about this novel method revealed a severe photopenic artifact ("halo artifact") around the urinary bladder causing significantly reduced tumor visibility. The aim of this evaluation was to analyze the role of arm truncation on the appearance of the halo artifact in 68Ga-PSMA-11 PET/MRI hypothesizing that this influences the appearance. METHODS: Twenty-seven consecutive patients were subjected to 68Ga-PSMA-11 PET/CT (1 h p.i.) followed by PET/MRI (3 h p.i.). PET/MRI was first started with scans of the abdomen to pelvis with arms positioned up above the head. Immediately thereafter, additional scans from the pelvis to abdomen were conducted with arms positioned down beside the trunk. All investigations were first analyzed separately and then compared with respect to tumor detection and tumor uptake (SUV) as well as the presence and intensity of the halo artifact. The Wilcoxon signed rank test was used to determine statistical differences including Bonferroni correction. RESULTS: The halo was significantly reduced if the arms were elevated. Lesions inside the halo artifact (n = 16) demonstrated significantly increased SUVmean (p = 0.0007) and SUVmax (p = 0.0024) with arms positioned up. The halo appearance and intensity was not dependent on the total activity and activity concentration of the urinary bladder. CONCLUSION: Positioning the arms down was shown to be significantly associated with the appearance of the halo artifact in PET/MRI. Positioning the arms up above the head can significantly reduce the halo artifact, thereby detecting more tumor lesions.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Afshar-Oromieh A, Wolf M, Haberkorn U, et al. Effects of arm truncation on the appearance of the halo artifact in 68Ga-PSMA-11 (HBED-CC) PET/MRI. Eur J Nucl Med Mol Imaging. 2017. PMID: 28508120. doi:10.1007/s00259-017-3718-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。