淋巴结与原发性肿瘤标准化摄取比值在浸润性宫颈鳞状细胞癌中的预后意义
本研究回顾性分析103例FIGO IB-IIA期宫颈鳞状细胞癌患者术前[18F]FDG PET/CT,评估淋巴结与宫颈原发灶SUV比值(SUVLN/SUVcervix)的预后价值。多因素logistic回归显示SUVLN/SUVcervix>0.1747(P=0.048)是复发的独立危险因素,按该比值分组患者无进展生存期(PFS)差异有统计学意义(log-rank检验,P<0.001)。
要点
- 术前[18F]FDG PET/CT测量的SUVLN/SUVcervix>0.1747是宫颈鳞癌复发的独立危险因素(P=0.048)。
- 按SUVLN/SUVcervix分组患者PFS差异有统计学意义(log-rank检验,P<0.001)。
- SUVLN/SUVcervix对宫颈鳞癌PFS具有增量预后价值。
核心结论
- 术前[18F]FDG PET/CT测量的SUVLN/SUVcervix与复发显著相关,对宫颈鳞癌患者PFS具有增量预后价值。
研究设计与样本
- 回顾性分析103例FIGO IB至IIA期宫颈鳞状细胞癌患者,术前接受[18F]FDG PET/CT检查。
- 评估原发宫颈癌最大标准化摄取値(SUVcervix)、淋巴结SUV(SUVLN)及SUVLN/SUVcervix等PET/CT参数。
- 采用回归分析预测无进展生存期(PFS),分析PET/CT代谢与体积变量及临床病理参数的预后价值。
主要发现
- 103例患者中位术后随访29个月(范围6-89个月),19例(18.5%)出现复发。
- 多因素logistic回归显示SUVLN/SUVcervix>0.1747(P=0.048)是复发的独立危险因素。
- 按SUVLN/SUVcervix分组的患者PFS差异有统计学意义(log-rank检验,P<0.001)。
关键数值与推荐
- SUVLN/SUVcervix>0.1747为复发的独立危险因素(P=0.048)。
- 按SUVLN/SUVcervix分组患者PFS差异有统计学意义(log-rank检验,P<0.001)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Using integrated PET/CT, we evaluated the prognostic value of [18F]FDG uptake ratio between pelvic lymph node (LN) and primary tumor in invasive squamous cell carcinoma (SCCA) of the uterine cervix. METHODS: We retrospectively reviewed patients with International Federation of Gynecology and Obstetrics (FIGO) stages IB to IIA cervical SCCA who underwent preoperative [18F]FDG PET/CT scans. PET/CT parameters such as maximum standardized uptake value (SUV) of the primary cervical cancer (SUVcervix) and LN (SUVLN), and the LN-to-cervical cancer SUV ratio (SUVLN/SUVcervix) were assessed. Prognostic values of PET/CT-derived metabolic and volumetric variables and clinicopathology parameters were analyzed to predict progression-free survival (PFS) in regression analyses. RESULTS: Clinical data, treatment modalities, and results were reviewed for 103 eligible patients. Median post-surgical follow-up was 29 months (range, 6-89), and 19 (18.5%) patients experienced recurrence. Multivariate logistic regression analysis showed that SUVLN / SUVcervix > 0.1747(P = 0.048) was the independent risk factor of recurrence. Patient group categorized by SUVLN/SUVcervix showed significant difference in PFS (log-rank test, P < 0.001). CONCLUSIONS: Preoperative SUVLN/SUVcervix measured by [18F]FDG PET/CT was significantly associated with recurrence, and has an incremental prognostic value for PFS in patients with cervical SCCA.
引用
- Chung HH, Cheon GJ, Kim JW, et al. Prognostic importance of lymph node-to-primary tumor standardized uptake value ratio in invasive squamous cell carcinoma of uterine cervix. Eur J Nucl Med Mol Imaging. 2017. PMID: 28534183. doi:10.1007/s00259-017-3729-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。