文献速递肿瘤 PET/CT

原发性前列腺癌患者中18F-PSMA-1007 PET/CT、多参数MRI与根治性前列腺切除标本的个体内比较:一项回顾性概念验证研究

Intraindividual Comparison of 18F-PSMA-1007 PET/CT, Multiparametric MRI, and Radical Prostatectomy Specimens in Patients with Primary Prostate Cancer: A Retrospective, Proof-of-Concept Study.
PubMed 文献 · J Nucl Med · 2017-05-04

该回顾性概念验证研究于2016年对10例活检证实的高危原发性前列腺癌患者行18F-PSMA-1007 PET/CT,其中9例在初诊过程中行多参数MRI(mpMRI),10例均行根治性前列腺切除术(RP)。按PI-RADS v2将前列腺分为38个区域进行定位与一致性分析,结果显示18F-PSMA-1007 PET/CT在完全一致分析中阴性预测值为68%、准确率为75%,mpMRI分别为88%和73%;结论认为18F-PSMA-1007 PET/CT用于前列腺癌精确局部分期有前景。

要点

  • 10例高危原发性前列腺癌患者行18F-PSMA-1007 PET/CT,其中9例行mpMRI,10例均行RP。
  • 完全一致分析中18F-PSMA-1007 PET/CT的阴性预测值为68%、准确率为75%。
  • 近完全一致分析中18F-PSMA-1007 PET/CT的阴性预测值为91%、准确率为93%。

核心结论

  • 与RP组织病理学比较表明,18F-PSMA-1007 PET/CT对前列腺癌的精确局部分期有前景。

研究设计与样本

  • 2016年对10例活检证实的高危原发性前列腺癌男性行18F-PSMA-1007 PET/CT,其中9例在初诊过程中行mpMRI,随后10例均行RP,回顾性进行一致性分析。
  • 按PI-RADS第2版将前列腺分为38个区域,对18F-PSMA-1007 PET/CT、mpMRI与RP标本进行定位与一致性分析,并对RP标本代表性切片补充PSMA染色。

主要发现

  • 完全一致分析中,18F-PSMA-1007 PET/CT的阴性预测值为68%、准确率为75%,mpMRI的阴性预测值为88%、准确率为73%。
  • 近完全一致分析中,18F-PSMA-1007 PET/CT的阴性预测值为91%、准确率为93%,mpMRI分别为91%和87%。
  • 回顾性联合mpMRI与PET/CT在完全一致分析中的准确率为81%,在近完全一致分析中的准确率为93%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

68Ga-prostate-specific membrane antigen (PSMA)-11 PET/CT represents an advanced method for the staging of primary prostate cancer (PCa) and diagnosis of recurrent or metastatic PCa. However, because of the narrow availability of 68Ga the development of alternative tracers is of high interest. The objective of this study was to examine the value of the new PET tracer 18F-PSMA-1007 for the staging of local disease by comparing it with multiparametric MRI (mpMRI) and radical prostatectomy (RP) histopathology. Methods: In 2016, 18F-PSMA-1007 PET/CT was performed in 10 men with biopsy-confirmed high-risk PCa. Nine patients underwent mpMRI in the process of primary diagnosis. Consecutively, RP was performed in all 10 men. Agreement analysis was performed retrospectively. PSMA staining was added for representative sections in RP specimen slices. Localization and agreement analysis of 18F-PSMA-1007 PET/CT, mpMRI, and RP specimens was performed by dividing the prostate into 38 sections as described in the prostate imaging reporting and data system (PI-RADS) (version 2). Sensitivity, specificity, positive predictive values, negative predictive values (NPVs), and accuracy were calculated for total and near-total agreement. Results:18F-PSMA-1007 PET/CT had an NPV of 68% and an accuracy of 75%, and mpMRI had an NPV of 88% and an accuracy of 73% for total agreement. Near-total agreement analysis resulted in an NPV of 91% and an accuracy of 93% for 18F-PSMA-1007 PET/CT and 91% and 87% for mpMRI, respectively. Retrospective combination of mpMRI and PET/CT had an accuracy of 81% for total and 93% for near-total agreement. Conclusion: Comparison with RP histopathology demonstrates that 18F-PSMA-1007 PET/CT is promising for accurate local staging of PCa.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Kesch C, Vinsensia M, Radtke JP, et al. Intraindividual Comparison of 18F-PSMA-1007 PET/CT, Multiparametric MRI, and Radical Prostatectomy Specimens in Patients with Primary Prostate Cancer: A Retrospective, Proof-of-Concept Study. J Nucl Med. 2017. PMID: 28473595. doi:10.2967/jnumed.116.189233

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。