用125I-碘代DPA-713 SPECT/CT显像小鼠慢性胰腺炎模型中的巨噬细胞聚集
在雨蛙素诱导的C57BL/6小鼠慢性胰腺炎模型中,诱导后7周行125I-碘代DPA-713 SPECT/CT或18F-FDG PET/CT显像。治疗组胰腺125I-碘代DPA-713摄取显著高于对照组(5.17%±1.18% vs 2.41%±0.34% ID/g,P=0.02)。离体荧光显微镜显示治疗组胰腺大量巨噬细胞浸润并与滞留的荧光探针共定位。
要点
- 治疗组小鼠胰腺125I-碘代DPA-713摄取显著高于对照组(5.17%±1.18% vs 2.41%±0.34% ID/g,P=0.02)。
- 18F-FDG PET/CT示雨蛙素处理小鼠胰腺摄取增强,但健康胰腺也有中等信号。
- DPA-713-IRDye800CW近红外荧光示治疗组胰腺、局灶肝和胃肠道摄取,对照组仅见泌尿排泄。
核心结论
- 这些数据支持应用125I-碘代DPA-713 SPECT/CT和DPA-713-IRDye800CW近红外荧光在活体小鼠中 delineate 胰腺、肝脏或肠道炎症。
研究设计与样本
- 用雨蛙素在C57BL/6小鼠中诱导慢性胰腺炎,并与注射生理盐水的对照小鼠对比。
- 诱导后7周用125I-碘代DPA-713 SPECT/CT或18F-FDG PET/CT显像。
- 在相同条件下测定125I-碘代DPA-713的生物分布,并用其荧光类似物DPA-713-IRDye800CW对一对小鼠显像以进行相关组织学检查。
主要发现
- 治疗组小鼠胰腺125I-碘代DPA-713摄取显著高于对照组(5.17%±1.18% vs 2.41%±0.34% ID/g,P=0.02),显像结果与此一致。
- 18F-FDG PET/CT显像中,雨蛙素处理小鼠胰腺摄取增强,健康胰腺也有中等信号。
- DPA-713-IRDye800CW近红外荧光显像示治疗组小鼠胰腺强摄取、局灶肝摄取和胃肠道摄取,对照组仅见泌尿排泄。
- 离体荧光显微镜显示治疗组(非对照组)胰腺大量巨噬细胞浸润并与滞留的荧光探针共定位。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Pancreatitis remains a diagnostic challenge in patients with mild to moderate disease, with current imaging modalities being inadequate. Given the prominent macrophage infiltration in chronic pancreatitis, we hypothesized that 125I-iodo-DPA-713, a small-molecule radiotracer that specifically targets macrophages, could be used with SPECT/CT to image pancreatic inflammation in a relevant experimental model. Methods: Chronic pancreatitis was induced with cerulein in C57BL/6 mice, which were contrasted with saline-injected control mice. The animals were imaged at 7 wk after induction using N,N-diethyl-2-(2-(3-125I-iodo-4-methoxyphenyl)-5,7-dimethylpyrazolo[1,5-a]pyrimidin-3-yl)acetamide (125I-iodo-DPA-713) SPECT/CT or 18F-FDG PET/CT. The biodistribution of 125I-iodo-DPA-713 was determined under the same conditions, and a pair of mice was imaged using a fluorescent analog of 125I-iodo-DPA-713, DPA-713-IRDye800CW, for correlative histology. Results: Pancreatic 125I-iodo-DPA-713 uptake was significantly higher in treated mice than control mice (5.17% ± 1.18% vs. 2.41% ± 0.34% injected dose/g, P = 0.02), as corroborated by imaging. Mice imaged with 18F-FDG PET/CT showed cerulein-enhanced pancreatic uptake in addition to a moderate signal from healthy pancreas. Near-infrared fluorescence imaging with DPA-713-IRDye800CW showed strong pancreatic uptake, focal liver uptake, and gastrointestinal uptake in the treated mice, whereas the control mice showed only urinary excretion. Ex vivo fluorescence microscopy revealed a large influx of macrophages in the pancreas colocalizing with the retained fluorescent probe in the treated but not the control mice. Conclusion: These data support the application of both 125I-iodo-DPA-713 SPECT/CT and DPA-713-IRDye800CW near-infrared fluorescence to delineate pancreatic, liver, or intestinal inflammation in living mice.
引用
- Foss CA, Liu L, Mease RC, et al. Imaging Macrophage Accumulation in a Murine Model of Chronic Pancreatitis with 125I-Iodo-DPA-713 SPECT/CT. J Nucl Med. 2017. PMID: 28522739. doi:10.2967/jnumed.117.189571
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。