评估心脏PET中心肌内飞行时间信噪比增益及随之降低的给药活度
研究在88例FDG肿瘤患者中测得飞行时间(TOF)参考信噪比增益为+23%±8.5%,用体模数据验证参数图像法可在心肌内量化信噪比增益,并应用于13例FDG心脏存活心肌患者,心肌内信噪比增益为+21%±2.8%。结论认为心肌内TOF信噪比增益与既定方法观察到的增益相当,可为TOF系统心脏PET的方案优化提供指导。
要点
- 88例FDG肿瘤患者中测得TOF参考信噪比增益为+23%±8.5%。
- 体模数据验证参数图像法量化心肌信噪比增益足够稳健。
- 13例FDG心脏存活心肌患者心肌内TOF信噪比增益为+21%±2.8%。
核心结论
- 已开发并评估一种量化心肌内TOF信噪比增益的方法,心肌内信噪比增益与既定方法观察到的增益相当,可为TOF系统心脏PET方案优化提供指导。
研究设计与样本
- 在88例FDG肿瘤患者中测量参考TOF信噪比增益。
- 用体模数据转换参考信噪比增益并验证从多次重复图像生成的参数图像量化心肌内信噪比增益的方法。
- 将该技术应用于13例FDG心脏存活心肌患者。
主要发现
- 肿瘤患者中参考TOF信噪比增益为+23%±8.5%。
- 体模数据的信噪比增益测量结果与参考一致,参数图像技术足够稳健。
- 存活心肌患者心肌内信噪比增益为+21%±2.8%。
关键数值与推荐
- 参考TOF信噪比增益+23%±8.5%(88例FDG肿瘤患者)。
- 心肌内TOF信噪比增益+21%±2.8%(13例FDG心脏存活心肌患者)。
临床怎么用
- 原文结论指出该心肌内TOF信噪比增益量化方法可为TOF系统心脏PET的方案优化提供指导。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Time-of-flight (TOF) is known to increase signal-to-noise ratio (SNR) and facilitate reductions in administered activity. Established measures of SNR gain are derived from areas of uniform uptake, which is not applicable to the heterogeneous uptake in cardiac PET images using fluoro-deoxyglucose (FDG). This study aimed to develop a technique to quantify SNR gains within the myocardium due to TOF. METHODS: Reference TOF SNR gains were measured in 88 FDG oncology patients. Phantom data were used to translate reference SNR gains and validate a method of quantifying SNR gains within the myocardium from parametric images produced from multiple replicate images. This technique was applied to 13 FDG cardiac viability patients. RESULTS: Reference TOF SNR gains of +23% ± 8.5% were measured in oncology patients. Measurements of SNR gain from the phantom data were in agreement and showed the parametric image technique to be sufficiently robust. SNR gains within the myocardium in the viability patients were +21% ± 2.8%. CONCLUSION: A method to quantify SNR gains from TOF within the myocardium has been developed and evaluated. SNR gains within the myocardium are comparable to those observed by established methods. This allows guidance for protocol optimization for TOF systems in cardiac PET.
引用
- Armstrong IS, Tonge CM, Arumugam P, et al. Assessing time-of-flight signal-to-noise ratio gains within the myocardium and subsequent reductions in administered activity in cardiac PET studies. J Nucl Cardiol. 2017. PMID: 28497418. doi:10.1007/s12350-017-0916-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。