双时间点FDG PET/CT显像在人工心脏瓣膜感染性心内膜炎中的应用
该研究比较了13例临床怀疑人工心脏瓣膜感染性心内膜炎(PVE)患者的标准(注射后60分钟)与延迟(注射后150分钟)FDG PET/CT图像,共14次扫描。延迟图像在视觉和半定量分析中均更易出现假阳性,标准图像视觉分析有1例假阴性和1例假阳性,延迟图像无假阴性但有5例假阳性。作者认为延迟FDG PET/CT显像对PVE似乎易出现假阳性结果,应谨慎解读。
要点
- 延迟FDG PET/CT图像在视觉和半定量分析中均更易出现假阳性。
- 标准图像视觉分析有1例假阴性和1例假阳性,延迟图像无假阴性但有5例假阳性。
- 延迟FDG PET/CT显像对PVE似乎易出现假阳性结果,应谨慎解读。
核心结论
- 延迟FDG PET/CT显像对PVE似乎易出现假阳性结果,因此应谨慎解读延迟图像。
研究设计与样本
- 本研究纳入13例临床怀疑PVE并转诊行FDG PET/CT的患者,共14次扫描,分别在标准时间点(注射后60分钟)和延迟时间点(注射后150分钟)进行图像采集。
- 最终诊断基于所有感染病例(n=6)的手术发现,其余病例(n=8)基于无异常的随访结果。
主要发现
- 延迟图像在视觉和半定量分析中均更易出现假阳性。
- 标准图像视觉分析产生1例假阴性和1例假阳性结果。
- 延迟图像视觉分析无假阴性扫描,但有5次扫描为假阳性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: FDG PET/CT has been of increasing interest in the diagnostic workup of prosthetic heart valve endocarditis (PVE). Some reports advocate later imaging time points to improve the diagnostic accuracy for PVE. In this study, we compared standard and late FDG PET/CT images in patients with a clinical suspicion of PVE. MATERIALS AND METHODS: Fourteen scans in 13 patients referred for FDG PET/CT for suspicion of PVE performed at standard (60 min post injection) and late (150 min post injection) time points were scored based on visual interpretation and semi-quantitatively with SUVmax and target-to-background ratio (TBR, defined as [SUVmax valve/SUVmean blood pool]). Final diagnosis was based on surgical findings in all cases of infection (n = 6) and unremarkable follow-up in all others (n = 8). RESULTS: Late images were more prone to false positive interpretation for both visual and semi-quantitative analyses. Visual analysis of the standard images yielded 1 false negative and 1 false positive result. On the late images, no scans were false negative but 5 scans were false positive. CONCLUSION: Late FDG PET/CT imaging for PVE seems prone to false positive results. Therefore, late imaging should be interpreted with caution.
引用
- Scholtens AM, Swart LE, Verberne HJ, et al. Dual-time-point FDG PET/CT imaging in prosthetic heart valve endocarditis. J Nucl Cardiol. 2017. PMID: 28474192. doi:10.1007/s12350-017-0902-3