文献速递心脏核医学

门控心肌灌注显像评价的左心室收缩失同步对灌注缺损评分正常的慢性肾脏病患者的预后价值

Prognostic value of left ventricular dyssynchrony evaluated by gated myocardial perfusion imaging in patients with chronic kidney disease and normal perfusion defect scores.
PubMed 文献 · J Nucl Cardiol · 2017-04-21

本研究纳入167例腺苷负荷201Tl门控心肌灌注SPECT灌注缺损评分正常且无明确心脏病史的慢性肾脏病患者,自动计算相位标准差(PSD)和带宽(BW),平均随访560天。12例(7.1%)发生主要不良心脏事件(MACE);发生MACE者PSD显著更高、BW更宽;高PSD宽BW组(n=81)心脏事件率显著高于低PSD窄BW组(n=71)(P=.002);多因素回归显示PSD与MACE相关(OR 1.33,95%CI 1.05-1.69,P=.01)。结论认为门控心肌灌注SPECT的左心室失同步指标可能成为灌注缺损评分正常CKD患者的新型预后预测因子。

要点

  • 167例灌注缺损评分正常的CKD患者中,12例(7.1%)发生MACE。
  • 发生MACE者PSD显著更高、BW显著更宽。
  • 高PSD宽BW组心脏事件率显著高于低PSD窄BW组(P=.002)。

核心结论

  • 门控心肌灌注SPECT获得的左心室失同步指标可能成为灌注缺损评分正常CKD患者的新型预后预测因子。

研究设计与样本

  • 研究纳入167例腺苷负荷201Tl门控心肌灌注SPECT灌注缺损评分正常且无既往明确心脏病史的慢性肾脏病患者,按是否发生MACE分为两组。

主要发现

  • 平均随访560天,12例(7.1%)发生MACE。
  • 发生MACE的患者PSD显著高于未发生MACE者,BW显著宽于未发生MACE者。
  • Kaplan-Meier无事件生存分析显示,高PSD宽BW组(n=81)心脏事件率显著高于低PSD窄BW组(n=71)(P=.002)。
  • 多因素回归分析显示PSD与MACE相关(OR 1.33,95%CI 1.05-1.69,P=.01)。

关键数值与推荐

  • MACE定义为心源性猝死、致命性心律失常和需紧急冠状动脉血运重建的急性冠脉综合征。
  • PSD与MACE的OR为1.33(95%CI 1.05-1.69,P=.01)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to investigate whether indices of left ventricular (LV) dyssynchrony by gated myocardial perfusion SPECT (GMPS) could be useful to predict prognosis in chronic kidney disease (CKD) patients with normal perfusion defect scores. METHODS: One hundred and sixty-seven CKD patients with normal perfusion defect scores on adenosine-stress 201Tl GMPS and no previous history of overt heart diseases were enrolled. Phase standard deviation (PSD) and bandwidth (BW) were automatically calculated from GMPS. The major adverse cardiac events (MACEs) for a mean of 560 days were defined as sudden cardiac death, fatal arrhythmias, and acute coronary syndrome requiring urgent coronary revascularization. Patients were divided into two groups according to the presence or absence of MACEs. RESULTS: The MACEs occurred in 12 patients (7.1%). Patients who experienced MACEs showed significantly higher PSD and wider BW than those who did not. In the Kaplan-Meier event-free survival analysis, cardiac event rate was significantly higher in the high-PSD and wide-BW group (n = 81) than in the low-PSD and narrow-BW group (n = 71) (P = .002). The multivariate regression analysis revealed that the PSD was associated with MACEs (odds ratio 1.33, 95% confidence interval 1.05-1.69, P = .01). CONCLUSION: The LV dyssynchrony indices from GMPS may be novel prognostic predictors in CKD patients with normal perfusion defect scores.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Mori H, Isobe S, Suzuki S, et al. Prognostic value of left ventricular dyssynchrony evaluated by gated myocardial perfusion imaging in patients with chronic kidney disease and normal perfusion defect scores. J Nucl Cardiol. 2017. PMID: 28432673. doi:10.1007/s12350-017-0889-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。