文献速递肿瘤 PET/CT放射性药物与辐射防护

利用新型PET探针18F-四氟硼酸盐靶向钠/碘同向转运体追踪树突状细胞向淋巴结的迁移

Tracking dendritic cell migration into lymph nodes by using a novel PET probe 18F-tetrafluoroborate for sodium/iodide symporter.
PubMed 文献 · EJNMMI Res · 2017-04-04

研究在小鼠中建立共表达人钠/碘同向转运体(hNIS)和effluc基因的树突状细胞系DC/NF,用18F-四氟硼酸盐(18F-TFB)PET/CT联合生物发光成像追踪其迁移。结果显示DC/NF注射部位及引流腘窝淋巴结在注射后第2天出现清晰信号,而亲本DC注射部位无信号,表明18F-TFB可用于hNIS报告基因成像以监测DC向淋巴结迁移。

要点

  • 18F-TFB PET/CT可显示hNIS报告基因转导的DC/NF细胞在注射部位及引流腘窝淋巴结的信号。
  • 注射后第2天,DC/NF注射侧的引流腘窝淋巴结放射性活性高于亲本DC注射侧。
  • 生物发光成像同样显示DC/NF细胞在第2天迁移至引流腘窝淋巴结。

核心结论

  • 在小鼠活体中,18F-TFB PET/CT成像hNIS基因联合effluc基因光学成像成功监测了DC向淋巴结的迁移。
  • 数据支持18F-TFB作为hNIS报告基因成像底物用于追踪活体动物中DC向淋巴结迁移的可行性。
  • 作者认为18F-TFB可能促进未来小动物和人类的hNIS报告基因PET成像。

研究设计与样本

  • 研究建立共表达hNIS和effluc基因的小鼠树突状细胞系DC2.4(DC/NF),并与亲本DC对照。
  • 将亲本DC和DC/NF细胞分别注射于小鼠左、右侧足垫,用18F-TFB PET/CT和生物发光成像(BLI)在活体中监测细胞。
  • 另将亲本DC和DC/NF细胞肌内注射后行BLI和18F-TFB PET/CT联合成像以确认细胞功能表达。

主要发现

  • 体内PET/CT和BLI在DC/NF注射部位显示清晰信号,而亲本DC注射部位无信号。
  • DC/NF细胞信号强度随时间相关。
  • 注射后第2天,18F-TFB PET/CT显示DC/NF注射侧的引流腘窝淋巴结放射性活性高于DC注射侧。
  • BLI显示注射后第2天DC/NF细胞迁移至引流腘窝淋巴结。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Recently, 18F-tetrafluoroborate (TFB) was used as a substrate for the human sodium/iodide symporter (hNIS) reporter gene. This study evaluated the feasibility of performing molecular-genetic imaging by using the new radiotracer (18F-TFB) for the hNIS gene, to track dendritic cell (DC) migration in live mice. A murine dendritic cell line (DC2.4) co-expressing the hNIS and effluc genes (DC/NF) was established. To confirm the functional cellular expression of both effluc and NIS in the inoculated DC/NF cells by bio-medical imaging, combined bioluminescence imaging (BLI) and 18F-TFB positron emission tomography/computed tomography (PET/CT) imaging was performed after intramuscular injection with parental DCs and DC/NF cells. For DC-tracking, parental DCs or DC/NF cells were injected in the left or right mouse footpad, respectively, and 18F-TFB PET/CT and BLI were performed to monitor these cells in live mice. RESULTS: In vivo PET/CT and BLI showed a clear signal in DC/NF injection sites but not in parental DC injection sites. The signal intensity in DC/NF cells was correlated with time. In vivo 18F-TFB PET/CT imaging showed higher radiotracer activity in the draining popliteal lymph nodes (DPLNs) in DC/NF injection sites than those in DC injection sites on day 2. BLI also showed DC/NF cell migration to the DPLNs on day 2 after the injection. CONCLUSIONS: Migration of DCs to the lymph nodes was successfully monitored using 18F-TFB PET/CT imaging of the NIS gene and optical imaging of the effluc gene in live mice. These data support the feasibility of using 18F-TFB as a substrate for hNIS reporter gene imaging to track the migration of DCs to the lymph nodes in live animals. The use of 18F-TFB may facilitate enhanced PET imaging of the hNIS reporter gene in small animals and humans in future studies.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Lee SB, Lee HW, Lee H, et al. Tracking dendritic cell migration into lymph nodes by using a novel PET probe 18F-tetrafluoroborate for sodium/iodide symporter. EJNMMI Res. 2017. PMID: 28378292. doi:10.1186/s13550-017-0280-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。